EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Guerit, J. M.
Right arrow Articles by Dion, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Guerit, J. M.
Right arrow Articles by Dion, R.

European Journal of Cardio-Thoracic Surgery, Vol 10, 93-103, Copyright © 1996 by European Association for Cardio-thoracic Surgery


ARTICLES

Multilevel somatosensory evoked potentials (SEPs) for spinal cord monitoring in descending thoracic and thoraco-abdominal aortic surgery

JM Guerit, R Verhelst, J Rubay, G Khoury, A Matta and R Dion
Clinical Neurophysiology Unit, Cliniques Universitaires St.-Luc, Brussels, Belgium.

The usefulness of somatosensory evoked potential (SEP) monitoring as a means of preventing paraplegia in descending aorta surgery was evaluated in 47 consecutive cases operated on for isthmic (14 cases), thoracic (22 cases), or thoraco-abdominal (11 cases) repair. An aortic dissection was found in 11 cases (acute in 6). Somatosensory evoked potentials were obtained by unilateral left and right posterior tibial nerve (PTN) stimulation at the ankle and recordings were performed on four channels: peripheral nerve, lumbar spinal, brain-stem, and cortical recordings. Our experience led to the following current strategy: the establishment of atrio(aorto)-femoral(aortic) bypass (29 cases), proximal and distal aortic cross-clamping, aortic repair with reimplantation of the culprit artery(ies) as indicated by SEP alterations. Five types of SEP alterations were defined on the basis of the neural level involved: type I (27.7% of cases) = distal spinal ischemia due to proximal aortic cross-clamping in the absence of bypass; type II (21.3%) = PTN ischemia due to left common femoral artery cross-clamping; type III (12.8%) = segmental spinal ischemia due to the exclusion of critical feeding arteries; type IV (4.3%) = ischemia in the left carotid artery territory; type V (4.3%) = global brain hypoperfusion due to systemic hypotension. Forty-five patients survived the operation and could be tested for neurological dysfunction. Three patients presented a postoperative spinal cord deficit, but this deficit was already present preoperatively in one case, so that the actual incidence of a new paraplegia in our series was 2/45 cases (4.4%). One of the two cases was clearly a delayed paraplegia with SEP alterations appearing several hours after the operation. Somatosensory evoked potentials were evaluated on the basis of their sensitivity, specificity, and impact on the surgical strategy. Regarding SEP sensitivity, we did not encounter any unexpected immediate paraplegia, but the critical factor appeared to be the duration of SEP absence due to spinal cord ischemia, which, according to the literature, should never exceed 30 min; after a longer absence, SEP return does not guarantee neurological recovery. Somatosensory evoked potential specificity was also 100%, but only 58% of the abnormalities found were actually consequent to spinal cord ischemia, the rest of the abnormalities being consequent to peripheral nerve or brain ischemia. Finally, SEP monitoring had a significant impact on surgical strategy in 19% of the cases. It is concluded that distal aortic perfusion and multilevel SEP monitoring play a significant role in preventing paraplegia in descending aorta surgery.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. E. Achouh, A. L. Estrera, C. C. Miller III, A. Azizzadeh, A. Irani, T. L. Wegryn, and H. J. Safi
Role of Somatosensory Evoked Potentials in Predicting Outcome During Thoracoabdominal Aortic Repair
Ann. Thorac. Surg., September 1, 2007; 84(3): 782 - 788.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. D. Etz, J. C. Halstead, D. Spielvogel, R. Shahani, R. Lazala, T. M. Homann, D. J. Weisz, K. Plestis, and R. B. Griepp
Thoracic and Thoracoabdominal Aneurysm Repair: Is Reimplantation of Spinal Cord Arteries a Waste of Time?
Ann. Thorac. Surg., November 1, 2006; 82(5): 1670 - 1677.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
J. C. Salengros, P. Pandin, F. Schuind, and A. Vandesteene
Intraoperative somatosensory evoked potentials to facilitate peripheral nerve release: [Les potentiels evoques somesthesiques peroperatoires pour faciliter la liberation de nerfs peripheriques]
Can J Anesth, January 1, 2006; 53(1): 40 - 45.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
T. B. Sloan
Electrophysiologic Monitoring during Surgery to Repair the Thoracoabdominal Aorta
Seminars in Cardiothoracic and Vascular Anesthesia, June 1, 2004; 8(2): 113 - 125.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J.-M. Guerit and R. A. Dion
State-of-the-art of neuromonitoring for prevention of immediate and delayed paraplegia in thoracic and thoracoabdominal aorta surgery
Ann. Thorac. Surg., November 1, 2002; 74(5): S1867 - 1869.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
I. Y.P. Wan, G. D. Angelini, A. J. Bryan, I. Ryder, and M. J. Underwood
Prevention of spinal cord ischaemia during descending thoracic and thoracoabdominal aortic surgery
Eur. J. Cardiothorac. Surg., February 1, 2001; 19(2): 203 - 213.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Ueda, H. Shimizu, A. Mori, I. Kashima, K. Moro, and S. Kawada
Selective perfusion of segmental arteries in patients undergoing thoracoabdominal aortic surgery
Ann. Thorac. Surg., July 1, 2000; 70(1): 38 - 43.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Ghariani, L. Liard, J. Spaey, P. H. Noirhomme, G. A. El Khoury, M. de Tourtchaninoff, R. A. Dion, and J.-M. Guerit
Retrospective study of somatosensory evoked potential monitoring in deep hypothermic circulatory arrest
Ann. Thorac. Surg., June 1, 1999; 67(6): 1915 - 1918.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J.-M. Guerit, C. Witdoeckt, R. Verhelst, A. J. Matta, L. M. Jacquet, and R. A. Dion
Sensitivity, specificity, and surgical impact of somatosensory evoked potentials in descending aorta surgery
Ann. Thorac. Surg., June 1, 1999; 67(6): 1943 - 1946.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. Noirhomme, Y. d'Udekem, E. Munting, G. El Khoury, Y. Humblet, and R. A. Dion
Resection of a Chest Chondrosarcoma Invading the Spine and the Aorta
Ann. Thorac. Surg., February 1, 1998; 65(2): 534 - 534.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.