EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gupta, R.
Right arrow Articles by Khalilullah, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gupta, R.
Right arrow Articles by Khalilullah, M.

European Journal of Cardio-Thoracic Surgery, Vol 10, 666-670, Copyright © 1996 by European Association for Cardio-thoracic Surgery


ARTICLES

Balloon mitral commissurotomy: an intraoperative assessment

R Gupta, SK Khanna, A Banerjee, RC Mishra, BK Gupta, M Nigam, DK Satsangi, AS Tomar, DK Tempe, R Arora and M Khalilullah
Department of Cardiothoracic Surgery, G.B. Pant Hospital, New Delhi, India.

OBJECTIVE: Advances in balloon catheter technology have revolutionized the management of obstructive cardiovascular diseases. For lesions like mitral stenosis, balloon commissurotomy has emerged as an alternative to surgical relief showing definite functional benefits in a few clinical trials, albeit with variable results. Such variability necessitated objective evaluation of the efficacy of balloon mitral commissurotomy. METHODS: The balloon mitral commissurotomy was carried out in 11 patients suffering from isolated mitral stenosis, under vision in a surgical setting. All patients were in NYHA class III/IV. Initially single balloon was used for mitral commissurotomy followed by double balloon, before completing the mitral valvotomy with surgical instruments whenever required. The commissural split was measured by firmly stretching the two commissures using nerve hooks and measuring the distance between the two hooks with the help of a caliper. Assessment of balloon dilation was made by calculating exact percentage of residual commissural split following balloon dilation as compared with completed mitral valvotomy. The exact percentage of commissural split was thus obtained by subtracting residual commissural split following balloon dilation from commissural split obtained after surgical open mitral valvotomy. RESULTS: Complete commissurotomy using the balloon technique was possible in two (18.2%) patients. In the remaining nine (81.8%) patients, balloon expansion provided only 50% to 80% of commissural split and required instrumental completion with good results. CONCLUSIONS: Balloon mitral commissurotomy, by virtue of its circumferential force, helps to develop a good cleavage and attains good hemodynamic improvement which may be life saving in critical mitral stenosis in selected group of patients with pliable mitral leaflets and minimal subvalvular pathology.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1996 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.