EJCTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fosse, E.
Right arrow Articles by Mohr, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fosse, E.
Right arrow Articles by Mohr, B.

European Journal of Cardio-Thoracic Surgery, Vol 11, 320-327, Copyright © 1997 by European Association for Cardio-thoracic Surgery


ARTICLES

Duraflo II coating of cardiopulmonary bypass circuits reduces complement activation, but does not affect the release of granulocyte enzymes : a European multicentre study

E Fosse, S Thelin, JL Svennevig, P Jansen, TE Mollnes, E Hack, P Venge, O Moen, V Brockmeier, E Dregelid, E Halden, L Hagman, V Videm, T Pedersen and B Mohr
Department of Thoracic Surgery and Anaesthesiology, Ullevaal Hospital, Oslo, Norway.

OBJECTIVE: This study was carried out to: (a) compare complement and granulocyte activation during cardiac operations in patients operated with cardiopulmonary bypass coated with heparin by the Duraflo II method, with activation in patients operated with uncoated circuits; and (b) relate complement, and granulocyte activation to selected adverse effects. METHODS: In a multicentre study among Rikshospitalet, Ullevaal Hospital in Norway and Uppsala University Hospital in Sweden, plasma concentrations of the complement activation products C4b/iC4b/C4c (C4bc), C3b/iC3b/C3c (C3bc), the terminal SC5b-9 complement complex (TCC), and the granulocyte proteins myeloperoxidase and lactoferrin were assessed in two groups of patients undergoing aortocoronary bypass. Seventy-six patients underwent surgery operated with circuits coated by the Duraflo II heparin coating and 75 uncoated circuits. The same amount of systemic heparin was administered to all patients. RESULTS: In both groups a significant increase in C4bc was first seen by the end of operation, from 86.7 +/- 12.5 to 273.0 +/- 277.4 nM in controls and from 86.9 +/- 18.5 to 320.2 +/- 190.5 nM in the control group, confirming previous documentation that the classical pathway is not activated during CPB, but as a consequence of protamin administration. The formation of C4bc did not differ significantly between the two groups. In the uncoated group the C3bc concentration increased from 124.0 +/- 15.3 to a maximum of 1176.1 +/- 64.7 nM (P < 0.01) and in the coated group it increased from 129.8 +/- 16.1 to a maximum of 1019.4 +/- 54.9 nM (P < 0.01) during CPB. Summary values but not peak values differed significantly between the groups. In the uncoated group the TCC concentration increased from 0.52 +/- 0.03 to a maximum value of 8.09 +/- 0.57 AU/ml (P < 0.01) while in the coated group the TCC concentration increased from a baseline of 0.53 +/- 0.03 to a peak value of 5.2 +/- 0.24 AU/ml (P <0.01). The difference between the peak values was statistically significant (P = 0.00002). In both groups a significant increase in myeloperoxidase and lactoferrin release was observed by the end of operation. There was no difference in myeloperoxidase or lactoferrin release between the two groups. TCC levels were compared to the occurrence of perioperative infarction, development of lung or renal failure, postoperative bleeding, time on ventilator and days in hospital. Three patients developed perioperative infarction; the peak levels of TCC were significantly higher in these patients than in the 148 patients that did not develop infarction. The reduction in TCC formation in the heparin-coated group was not associated with differences in any of the other clinical parameters. Few adverse effects occurred in the study. The peak values of C3bc were higher in the patients needing inotropic support that in those who did not, the relevance of this finding remains uncertain. CONCLUSION: It is concluded that the Duraflo II heparin coating reduces complement activation, particularly TCC formation, during CPB, but not the release of specific neutrophil granule enzymes. No certain correlation was established between complement and granulocyte activation and clinical outcome.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
J. W. Hammon
Extracorporeal Circulation: The Response of Humoral and Cellular Elements of Blood to Extracorporeal Circulation
Card. Surg. Adult, January 1, 2008; 3(2008): 370 - 389.
[Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
O. Mangoush, S. Purkayastha, S. Haj-Yahia, J. Kinross, M. Hayward, F. Bartolozzi, A. Darzi, and T. Athanasiou
Heparin-bonded circuits versus nonheparin-bonded circuits: an evaluation of their effect on clinical outcomes
Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1058 - 1069.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al.
Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline
Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Quaniers, J. Leruth, A. Albert, R. R. Limet, and J.-O. Defraigne
Comparison of inflammatory responses after off-pump and on-pump coronary surgery using surface modifying additives circuit.
Ann. Thorac. Surg., May 1, 2006; 81(5): 1683 - 1690.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
S. G Raja and G. D Dreyfus
Modulation of Systemic Inflammatory Response after Cardiac Surgery
Asian Cardiovasc Thorac Ann, December 1, 2005; 13(4): 382 - 395.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
T. N Hoel, V. Videm, S. T Baksaas, T. E Mollnes, F. Brosstad, and J. L Svennevig
Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery
Perfusion, May 1, 2004; 19(3): 177 - 184.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. M. Palatianos, C. N. Foroulis, M. I. Vassili, G. Astras, K. Triantafillou, E. Papadakis, A. A. Lidoriki, E. Iliopoulou, and E. N. Melissari
A prospective, double-blind study on the efficacy of the bioline surface-heparinized extracorporeal perfusion circuit
Ann. Thorac. Surg., July 1, 2003; 76(1): 129 - 135.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
P. Menasche and L. H. Edmunds Jr.
Extracorporeal Circulation: The Inflammatory Response
Card. Surg. Adult, January 1, 2003; 2(2003): 349 - 360.
[Full Text]


Home page
PerfusionHome page
L.-C. Hsu
Heparin-coated cardiopulmonary bypass circuits: current status
Perfusion, September 1, 2001; 16(5): 417 - 428.
[Abstract] [PDF]


Home page
PerfusionHome page
G Matheis, M Scholz, J Gerber, U Abdel-Rahman, G Wimmer-Greinecker, and A Moritz
Leukocyte filtration in the early reperfusion phase on cardiopulmonary bypass reduces myocardial injury
Perfusion, January 1, 2001; 16(1): 43 - 49.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
J.-O. Defraigne, J. Pincemail, R. Larbuisson, F. Blaffart, and R. Limet
Cytokine release and neutrophil activation are not prevented by heparin-coated circuits and aprotinin administration
Ann. Thorac. Surg., April 1, 2000; 69(4): 1084 - 1091.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. P. Wendel and G. Ziemer
Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation
Eur. J. Cardiothorac. Surg., September 1, 1999; 16(3): 342 - 350.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
V. Videm, T. E. Mollnes, K. Bergh, E. Fosse, B. Mohr, T.-A. Hagve, A. O. Aasen, and J. L. Svennevig
HEPARIN-COATED CARDIOPULMONARY BYPASS EQUIPMENT. II. MECHANISMS FOR REDUCED COMPLEMENT ACTIVATION IN VIVO
J. Thorac. Cardiovasc. Surg., April 1, 1999; 117(4): 803 - 809.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.