EJCTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hruda, J.
Right arrow Articles by Samanek, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hruda, J.
Right arrow Articles by Samanek, M.

European Journal of Cardio-Thoracic Surgery, Vol 12, 184-189, Copyright © 1997 by European Association for Cardio-thoracic Surgery


ARTICLES

Good exercise tolerance and impaired lung function after atrial repair of transposition

J Hruda, J Sulc, J Radvansky, B Hucin and M Samanek
Kardiocentrum, University Hospital Motol, Prague, Czech Republic. jaroslav.hruda@lfmotol.cuni.cz

OBJECTIVE: Evaluation of long-term results of atrial correction of transposition of the great arteries (TGA), focusing on the relationship between pulmonary function and exercise tolerance. METHODS: A prospective population-based study-56 out of 60 survivors of Mustard/Senning repair, born in Bohemia in 1980-1984 (median age at surgery 0.85 years) were followed up over 13.4 +/- 1.2 years and studied by complete lung function and bicycle exercise testing. RESULTS: Maximum heart rate on exercise reached 181 +/- 14 bpm (Z- score: -1.06 +/- 1.66, range -6.7 to +1.6); VO2max: 40.6 +/- 6.7 ml/kg per min (Z-score: -0.97 +/- 1.4, range -5 to +1.8). A total of 73.6% had abnormal lung function, most frequently features of stiff lung (39.6%) and lung restriction (32.1%). Static recoil pressure of the lungs measured at 100, 90 and 60% of total lung capacity reached 137, 126 and 130%, respectively (Z-score: 1.93 +/- 2.33, 1.64 +/- 1.96, and 1.14 +/- 1.95, respectively). There was an inverse relationship between static recoil pressure of the lungs and VO2max (r = -0.306, P = 0.043), indicating the impact of lung function abnormalities on exercise tolerance. Comparison with lung function study of the group of 'pioneer' Mustard patients operated at the mean age of 4.4 years revealed a similar pattern and frequency (73.6% in current series vs. 88%, NS). CONCLUSIONS: Long-term follow-up has shown good exercise tolerance in the majority of patients after atrial correction of TGA performed in infancy. Many of them, however, have impaired lung function, especially stiff lung, although less frequently than original patients operated at a later age. The stiff lung can impair the exercise tolerance.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.