EJCTS Click here to locate an Ethicon representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Mohammed Akhter
Thomas Z Lajos
Gary Grosner
Jacob Bergsland
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Akhter, M.
Right arrow Articles by Visco, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Akhter, M.
Right arrow Articles by Visco, J.

Eur J Cardiothorac Surg 1998;14:S58-S61
© 1998 Elsevier Science NL

Minimally invasive coronary artery bypass grafting using the right gastroepiploic artery without pump

Mohammed Akhter, Thomas Z Lajos*, Gary Grosner, Jacob Bergsland, John Visco

State University of New York at Buffalo and The Buffalo General Hospital Division of Cardiac Surgery, Buffalo, NY, USA

* Corresponding author. 100 High Street, Buffalo, NY 14203, USA. Tel.: +1 716 859 2249; fax: +1 716 859 2885.

Objective: To explore the feasibility to operate on the right coronary artery and its branches utilizing the right gastroepiploic artery (RGEA) without cardiopulmonary bypass (CPB). All cases were performed since May 1996. Methods: A small mid-line incision including splitting of the lower sternum gave excellent exposure. The inferior surface of the heart was dissected to expose and stabilize the target vessel. The heart rate was controlled with a Diltiazem drip. CPB was not necessary in any case. The right coronary artery was bypassed in four patients, the posterior descending artery branch in five patients and the terminal circumflex of the left coronary artery in one patient. After grafting, patency of the anastomosis was demonstrated by Doppler echocardiogram. Results: No patient had perioperative mortality or complications. No patient had recurrent angina. Color Doppler echocardiographic imaging studies before discharge confirmed patency of the graft in eight of ten cases. In two cases, the gastroepiploic artery could not be visualized. Angiographic visualization was positive in four out of five cases. Conclusions: The gastroepiploic artery is an excellent conduit for vascularization of the inferior aspect of the heart. The operation can be done using a minimally invasive technique and without the use of cardiopulmonary bypass. This approach seems especially applicable in selective reoperative cases.

Key Words: Gastroepiploic bypass • Off pump • Minimally invasive







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.