|
|
||||||||
Eur J Cardiothorac Surg 1999;15:127-133
© 1999 Elsevier Science NL
a Department of Cardiac Surgery, University of Heidelberg, Heidelberg, Germany
b Department of Medical and Biological Informatics, Deutsches Krebsforschungszentrum, Heidelberg, Germany
Received 21 September 1998; received in revised form 7 December 1998; accepted 16 December 1998.
* Corresponding author. University of Heidelberg, Abteilung für Herzchirurgie, Im Neuenheimer Feld, 120 D-69120 Heidelberg, Germany. Tel.: +49-6221-56-6272; fax: +49-6221-56-5585; e-mail: r.de.simone@urz.uni-heidelberg.de
Objective: Transesophageal color Doppler (or 2D Doppler) is the most widely used technique for intraoperative assessment of mitral valve repair. However, the most severe mitral regurgitations produce eccentric jet flows which cannot be assessed by 2D imaging. Up to now the indications for surgical intervention and intraoperative decisions after valve repair have been based on 2D Doppler examinations. Aim of this study was to compare conventional 2D Doppler to three-dimensional (3D) Doppler for assessing residual regurgitation in patients after mitral valvuloplasty. Methods: Twenty-four patients were referred to surgery for mitral valve repair. They underwent transesophageal echocardiography and 3D data acquisition during mitral valve reconstruction. Conventional assessment of mitral valve regurgitation, measured by color Doppler jet area, was compared to the volume of regurgitant jets obtained by 3D Doppler. Regurgitant volume and fraction were measured by pulsed Doppler and two-dimensional echocardiography. The 3D reconstructions of color Doppler data were accomplished by means of the `Heidelberg Raytracing Algorithm' developed at our institution. Results: The jet areas did not show any significant correlation to the regurgitant fraction (r=45; P=NS) or regurgitant volumes (r=0.40; P=NS). In contrast the jet volumes correlated significantly to regurgitant fraction (r=0.71; P<0.01) and regurgitant volume (r=0.85; P<0.01). The reproducibility analysis of repeated jet volume and jet area measurements also showed that the parameter jet volume has a lower variability and higher agreement of repeated measurements than jet area. Conclusions: Three-dimensional color Doppler flow imaging revealed the complex geometry of eccentric regurgitant jets and showed that the assessment of mitral regurgitation, based on conventional 2D Doppler, can be misleading. This new technique has a great potential for becoming a reference method for assessing mitral valve repair.
Key Words: Mitral valve regurgitation Mitral valvuloplasty Color Doppler echocardiography Transesophageal echocardiography Intraoperative echocardiography Three-dimensional color Doppler
This article has been cited by other articles:
![]() |
R. De Simone, I. Wolf, S. Mottl-Link, R. Hoda, B. Mikhail, F.-U. Sack, H.-P. Meinzer, and S. Hagl A clinical study of annular geometry and dynamics in patients with ischemic mitral regurgitation: new insights into asymmetrical ring annuloplasty Eur. J. Cardiothorac. Surg., March 1, 2006; 29(3): 355 - 361. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Gabriel, O. Kamp, and C. A. Visser Three-dimensional echocardiography in mitral valve disease Eur J Echocardiogr, December 1, 2005; 6(6): 443 - 454. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. De Simone, I. Wolf, S. Mottl-Link, B. W. Bottiger, H. Rauch, H.-P. Meinzer, and S. Hagl Intraoperative assessment of right ventricular volume and function Eur. J. Cardiothorac. Surg., June 1, 2005; 27(6): 988 - 993. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. D. Cheitlin, W. F. Armstrong, G. P. Aurigemma, G. A. Beller, F. Z. Bierman, J. L. Davis, P. S. Douglas, D. P. Faxon, L. D. Gillam, T. R. Kimball, et al. ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article: a report of the American college of cardiology/American heart association task force on practice guidelines (ACC/AHA/ASE committee to update the 1997 guidelines for the clinical application of echocardiography) J. Am. Coll. Cardiol., September 3, 2003; 42(5): 954 - 970. [Full Text] [PDF] |
||||
![]() |
M. D. Cheitlin, W. F. Armstrong, G. P. Aurigemma, G. A. Beller, F. Z. Bierman, J. L. Davis, P. S. Douglas, D. P. Faxon, L. D. Gillam, T. R. Kimball, et al. ACC/AHA/ASE 2003 Guideline Update for the Clinical Application of Echocardiography: Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography) Circulation, September 2, 2003; 108(9): 1146 - 1162. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |