Eur J Cardiothorac Surg 1999;15:564-570
© 1999 Elsevier Science NL
Division of Thoracic and Cardiovascular Surgery, Surgical center, Hannover Medical School, Carl-Neuberg-Strase 1, 30625 Hannover, Germany
Received 7 December 1998; received in revised form 8 February 1999; accepted 10 February 1999.
Corresponding author. Tel./fax: +49-511-5233447
e-mail: karck{at}thg.mh-hannover.de
Objectives: The Gelatin-resorcin-formalin (GRF) glue is widely used in the surgical treatment of dissecting aneurysms. This paper is focused on our experience with the GRF glue in cases, operated for acute aortic dissection type A. Methods: Between September 1990 and December 1997, 164 patients were operated on for acute aortic dissection type A. In 148 patients GRF was used to reinforce the dissected layers proximal (n=106) or distal (n=144) of the grafted aortic segment. An intervention at the aortic valve was necessary in 93 instances. In 111 patients, an open distal anastomosis for replacement of the proximal aortic arch was performed. Thirty-seven additional patients underwent subtotal or total aortic arch replacement. Results: Early postoperative mortality was 26.2% (43/164 patients). Another 16 patients died late postoperatively. Actuarial survival rates are 69.9% at 1 year, 62.5% at 3 years, 59.4% at 5 years and 56.1% at 7 years, postoperatively. Twenty-two reoperations were performed in 20 patients (16.5%). Nine of these patients had developed complications in aortic segments that underwent reconstruction by use of GRF during the primary intervention. Aortic root redissection was found in 7/9 patients intraoperatively, whereas 1/9 patients presented with a rupture near the distal graft to aortic anastomosis. Conclusions: The introduction of GRF glue has greatly facilitated the reconstruction of dissected aortic wall layers adjacent to the vascular graft. However, the use of the adhesive for aortic root reconstruction in acute aortic dissection type A may bear a significant risk of late postoperative proximal aortic redissection. Complications associated with the GRF glue are likely to be due to the toxic effects of the formalin component. Therefore, care should be taken that the amount of formalin administered to the glue components remains as low as possible.
Key Words: Acute aortic dissection Surgical treatment Gelatin-resorcin-formalin glue
This article has been cited by other articles:
![]() |
M. Shrestha, N. Khaladj, C. Hagl, and A. Haverich Valve-Sparing Aortic Root Stabilization in Acute Type A Aortic Dissection Asian Cardiovasc Thorac Ann, January 1, 2009; 17(1): 22 - 24. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. Van Nooten, P. Somers, R. Forsyth, K. Narine, Y. Van Belleghem, S. Jacobs, and F. De Somer Autologous glue: Part of the sticky mystery unraveled J. Thorac. Cardiovasc. Surg., August 1, 2007; 134(2): 415 - 423. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Ohata, Y. Miyamoto, M. Mitsuno, M. Yamamura, H. Tanaka, and M. Ryomoto Modified Sandwich Technique for Acute Aortic Dissection Asian Cardiovasc Thorac Ann, June 1, 2007; 15(3): 261 - 263. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Hata, H. Takano, G. Matsumiya, N. Fukushima, N. Kawaguchi, and Y. Sawa Late Complications of Gelatin-Resorcin-Formalin Glue in the Repair of Acute Type A Aortic Dissection Ann. Thorac. Surg., May 1, 2007; 83(5): 1621 - 1626. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. W. Erasmi, H.-H. Sievers, J.F. M. Bechtel, T. Hanke, U. Stierle, and M. Misfeld Remodeling or Reimplantation for Valve-Sparing Aortic Root Surgery? Ann. Thorac. Surg., February 1, 2007; 83(2): S752 - S756. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Tanaka, K. Morioka, W. Li, N. Yamada, A. Takamori, M. Handa, S. Tanabe, and A. Ihaya Adventitial inversion technique without the aid of biologic glue or Teflon buttress for acute type A aortic dissection Eur. J. Cardiothorac. Surg., December 1, 2005; 28(6): 864 - 869. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. S.H. Tan, W. J. Morshuis, K. M.E. Dossche, J. C. Kelder, F. G.J. Waanders, and M. A.A.M. Schepens Long-Term Results After 27 Years of Surgical Treatment of Acute Type A Aortic Dissection Ann. Thorac. Surg., August 1, 2005; 80(2): 523 - 529. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Halstead, D. Spielvogel, D. M. Meier, S. Rinke, C. Bodian, R. Malekan, M. A. Ergin, and R. B. Griepp Composite aortic root replacement in acute type A dissection: time to rethink the indications? Eur. J. Cardiothorac. Surg., April 1, 2005; 27(4): 626 - 632. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Hoschtitzky, L. Crawford, M. Brack, and J. Au Reply to Mastroroberto et al. Eur. J. Cardiothorac. Surg., March 1, 2005; 27(3): 532 - 532. [Full Text] [PDF] |
||||
![]() |
Z. Mahmood, D. S. Cook, H. Luckraz, and P. O'Keefe Fatal right ventricular infarction caused by Bioglue coronary embolism J. Thorac. Cardiovasc. Surg., November 1, 2004; 128(5): 770 - 771. [Full Text] [PDF] |
||||
![]() |
M. Hata, M. Shiono, A. Sezai, M. Iida, N. Negishi, and Y. Sezai Type A acute aortic dissection: Immediate and mid-term results of emergency aortic replacement with the aid of gelatin resorcin formalin glue Ann. Thorac. Surg., September 1, 2004; 78(3): 853 - 857. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Yoshitatsu, F. Nomura, A. Katayama, K. Tamura, K. Katayama, K. Ihara, and Y. Nakashima Pathologic findings of aortic redissection after glue repair of proximal aorta J. Thorac. Cardiovasc. Surg., February 1, 2004; 127(2): 593 - 595. [Full Text] [PDF] |
||||
![]() |
D. T. Lai, D. C. Miller, R. S. Mitchell, P. E. Oyer, K. A. Moore, R. C. Robbins, N. E. Shumway, and B. A. Reitz Acute type a aortic dissection complicated by aortic regurgitation: composite valve graft versus separate valve graft versus conservative valve repair J. Thorac. Cardiovasc. Surg., December 1, 2003; 126(6): 1978 - 1985. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Kallenbach, K. Pethig, R.G. Leyh, D. Baric, A. Haverich, and W. Harringer Acute dissection of the ascending aorta: first results of emergency valve sparing aortic root reconstruction Eur. J. Cardiothorac. Surg., August 1, 2002; 22(2): 218 - 222. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kirsch, M. Ginat, L. Lecerf, R. Houel, and D. Loisance Aortic wall alterations after use of gelatin-resorcinol-formalin glue Ann. Thorac. Surg., February 1, 2002; 73(2): 642 - 644. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kirsch, C. Soustelle, R. Houel, M. L. Hillion, and D. Loisance Risk factor analysis for proximal and distal reoperations after surgery for acute type A aortic dissection J. Thorac. Cardiovasc. Surg., February 1, 2002; 123(2): 318 - 325. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Murashita, T. Kunihara, N. Shiiya, H. Aoki, K. Myojin, and K. Yasuda Is preservation of the aortic valve different between acute and chronic type A aortic dissections? Eur. J. Cardiothorac. Surg., November 1, 2001; 20(5): 967 - 972. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Tsukui, S. Aomi, H. Nishida, M. Endo, and H. Koyanagi Ostial stenosis of coronary arteries after complete replacement of aortic root using gelatin-resorcinol-formaldehyde glue Ann. Thorac. Surg., November 1, 2001; 72(5): 1733 - 1735. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kazui, N. Washiyama, Abul Hasan Muhammad Bashar, H. Terada, K. Suzuki, K. Yamashita, and M. Takinami Role of biologic glue repair of proximal aortic dissection in the development of early and midterm redissection of the aortic root Ann. Thorac. Surg., August 1, 2001; 72(2): 509 - 514. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Raanani, D. A. Latter, L. E. Errett, D. B. Bonneau, Y. Leclerc, and G. C. Salasidis Use of ""BioGlue"" in aortic surgical repair Ann. Thorac. Surg., August 1, 2001; 72(2): 638 - 640. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. W. Hewitt, S. W. Marra, B. R. Kann, H. S. Tran, M. M. Puc, F. A. Chrzanowski Jr, J.-L. V. Tran, S. D. Lenz, J. H. Cilley Jr, V. A. Simonetti, et al. BioGlue surgical adhesive for thoracic aortic repair during coagulopathy: efficacy and histopathology Ann. Thorac. Surg., May 1, 2001; 71(5): 1609 - 1612. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. E. Rasmussen and J. M. Panneton Ischemic Complications of Distal Aortic Dissections: Open Surgical or Endovascular Management? Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 2001; 14(2): 57 - 71. [Abstract] [PDF] |
||||
![]() |
T. P. Graeter, F. Langer, N. Nikoloudakis, D. Aicher, and H.-J. Schafers Valve-preserving operation in acute aortic dissection type A Ann. Thorac. Surg., November 1, 2000; 70(5): 1460 - 1465. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Martinelli, A. Graffigna, M. Guarnerio, R. Bonmassari, and M. Disertori Coronary artery narrowing after aortic root reconstruction with resorcin-formalin glue Ann. Thorac. Surg., November 1, 2000; 70(5): 1701 - 1702. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. P. Casselman, M. E. S.H. Tan, F. E.E. Vermeulen, J. C. Kelder, W. J. Morshuis, and M. A.A.M. Schepens Durability of aortic valve preservation and root reconstruction in acute type A aortic dissection Ann. Thorac. Surg., October 1, 2000; 70(4): 1227 - 1233. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. G. Leyh, C. Schmidtke, C. Bartels, and H.-H. Sievers Valve-sparing aortic root replacement (remodeling/reimplantation) in acute type A dissection Ann. Thorac. Surg., July 1, 2000; 70(1): 21 - 24. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Bingley, M. A.H. Gardner, E. G. Stafford, T. K. Mau, P. G. Pohlner, R. K.W. Tam, H. Jalali, P. J. Tesar, and M. F. O'Brien Late complications of tissue glues in aortic surgery Ann. Thorac. Surg., June 1, 2000; 69(6): 1764 - 1768. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. P. Carrel Invited commentary Ann. Thorac. Surg., June 1, 2000; 69(6): 1768 - 1768. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |