EJCTS Click here to go to Edwards website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Anno Diegeler
Volkmar Falk
Christian Binner
Thomas Walther
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Diegeler, A.
Right arrow Articles by Mohr, F.-W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Diegeler, A.
Right arrow Articles by Mohr, F.-W.

Eur J Cardiothorac Surg 1999;16:S67-S72
© 1999 Elsevier Science NL

Quality assessment in minimally invasive coronary artery bypass grafting

Anno Diegeler*, Merhajoddin Matin, Volkmar Falk, Christian Binner, Thomas Walther, Rüdiger Autschbach, Friedrich-Wilhelm Mohr

University of Leipzig, Heartcenter, Clinic of Cardiac Surgery, Russenstrasse 19, D 04289 Leipzig, Germany

* Corresponding author. Tel.: +49-341-865-1421; fax: +49-341-869-1452 (Email: diea{at}server3.medizin.uni-leipzig.de).

Objectives: The most important determinant for the success of minimally invasive coronary artery bypass grafting (MIDCAB) is the quality and long-term patency of the graft and anastomosis. Intra and postoperative quality assessment is important to confirm the safety and effectiveness of minimally invasive techniques. Methods: From January to December 1998 MIDCAB was performed in 246 patients using a limited minithoracotomy for single left anterior descending artery (LAD) revascularization. According to our standard protocol quality assessment of the graft and anastomosis consisted of intraoperative flow measurement, early postoperative angiography and follow-up angiography after 6 months. Results: Intraoperative flow measurement was performed in patients with anastomoses unsuitable for coronary probing (75/246, mean flow of 34.3±17.7 ml/min). Early patency was confirmed by intraoperative monoplane angiogram in 37/246 (15.0%) patients and by postoperative multiplan angiography in 205/246 (83.3%). Early patency rate was 98.0%. Six months follow-up showed a patency rate of 97.5% (one occluded graft, two severe and two moderate stenoses at the anastomotic site). Eighty-nine percent of the patients were in a CCS angina class I, 11% in class II, respectively. Six months mortality was 0.8%. Re-intervention had to be performed in 5/116 (4.3%). Conclusions: A standardized protocol for quality assessment is mandatory for MIDCAB surgery. The proposed algorithm serves to ensure the safety and effectiveness of this new technique. Our recent series document an excellent outcome of the MIDCAB approach. Postoperative multiplan angiography is the only technique to achieve valid information about the quality of graft and anastomosis.

Key Words: Quality assessment in CABG • MIDCAB • Coronary probe • Transit time flow measurement • Coronary angiography




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. de Canniere, G. Wimmer-Greinecker, R. Cichon, V. Gulielmos, F. Van Praet, U. Seshadri-Kreaden, and V. Falk
Feasibility, safety, and efficacy of totally endoscopic coronary artery bypass grafting: Multicenter European experience
J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 710 - 716.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. J. Drenth, N. J. G. M. Veeger, J. B. Winter, J. G. Grandjean, M. A. Mariani, A. d J. Boven van, and P. W. Boonstra
A prospective randomized trial comparing stenting with off-pump coronary surgery for high-grade stenosis in the proximal left anterior descending coronary artery: three-year follow-up
J. Am. Coll. Cardiol., December 4, 2002; 40(11): 1955 - 1960.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. J. Drenth, J. B. Winter, N. J. G. M. Veeger, S. H. J. Monnink, A. J. van Boven, J. G. Grandjean, M. A. Mariani, and P. W. Boonstra
Minimally invasive coronary artery bypass grafting versus percutaneous transluminal coronary angioplasty with stenting in isolated high-grade stenosis of the proximal left anterior descending coronary artery: Six months' angiographic and clinical follow-up of a prospective randomized study
J. Thorac. Cardiovasc. Surg., July 1, 2002; 124(1): 130 - 135.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Dogan, T. Aybek, E. Andre{beta}en, C. Byhahn, S. Mierdl, K. Westphal, G. Matheis, A. Moritz, and G. Wimmer-Greinecker
Totally endoscopic coronary artery bypass grafting on cardiopulmonary bypass with robotically enhanced telemanipulation: Report of forty-five cases
J. Thorac. Cardiovasc. Surg., June 1, 2002; 123(6): 1125 - 1131.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.