EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Joachim Laas
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kleine, P.
Right arrow Articles by Laas, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kleine, P.
Right arrow Articles by Laas, J.

Eur J Cardiothorac Surg 2000;17:20-24
© 2000 Elsevier Science NL

Downstream turbulence and high intensity transient signals (HITS) following aortic valve replacement with Medtronic Hall or St. Jude Medical valve substitutes

Peter Kleinea, Mathias Perthela, J. Michael Hasenkamb, Hans Nygaardb, Søren B. Hansenb, Joachim Laasa

a Department of Cardio-thoracic Surgery, Herz-Kreislauf-Klinik Bevensen, Römstedter Str. 25, 29549 Bad Bevensen, Germany
b Department of Cardiovascular Research, University Hospital Skejby Sygehus, Brendstrupgrdsvej, DK-8200 Aarhus, Denmark

Corresponding author. Tel.: +49-5821-821-702; fax: +49-5821-821-777
e-mail: prof.laas{at}t-online.de

Objective: High intensity transient signals (HITS) representing microembolization to the brain have been found to contribute to cognitive impairment and psychoneurological dysfunction in patients carrying a mechanical aortic valve. It is unknown, whether HITS represent gaseous or solid emboli. This animal study evaluates the impact of valve orientation on HITS for two different mechanical valves with both valves implanted in their best and worst orientation, which has been defined in previous studies with respect to downstream turbulence. Methods: In four pigs a rotation device carrying either a Medtronic Hall (MH) or St. Jude Medical (SJM) valve size 23 mm was implanted. The device allowed rotation of the implanted valves without reopening of the aorta. Approximately 30 min after weaning from extracorporeal circulation, a Doppler probe was placed on both common carotid arteries. In different orientations of the implanted valves (best and worst position), HITS were detected by the Doppler probe and recorded for ten min by a transcranial Doppler sonography device (Medilab Inc., Estenfeld, Germany). Results: HITS showed significant change with rotation for both valve designs. With the major orifice of the MH oriented towards the non-coronary leaflet (optimum position) very low HITS-counts (0.8–1.7/min) were observed. In the worst orientation HITS rose to 43–66/min. For the SJM the HITS count in the optimum position was 23.4–24/min and in the worst orientation 38–48/min. Conclusions: Valve orientation has an important impact on microembolization to the brain. In the optimum orientation (large orifice facing the non-coronary leaflet) the Medtronic Hall valve showed neglectible incidence of HITS. The St. Jude Medical bileaflet valve showed less variation but demonstrated significant HITS counts at any orientation. As the MH in the worst position shows significantly higher turbulent stresses than the SJM but no higher incidence of HITS, a strong correlation between turbulence and HITS was not demonstrated by this study.

Key Words: High intensity transient signals • Prosthetic heart valves • Medtronic • St. Jude Medical




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. Guerrieri Wolf, B. P. Choudhary, Y. Abu-Omar, and D. P. Taggart
Solid and gaseous cerebral microembolization after biologic and mechanical aortic valve replacement: Investigation with multirange and multifrequency transcranial Doppler ultrasound
J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 512 - 520.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. Machler, G. Reiter, M. Perthel, U. Reiter, P. Bergmann, M. Zink, R. Rienmuller, and J. Laas
Influence of a tilting prosthetic mitral valve orientation on the left ventricular flow -- an experimental in vivo magnetic resonance imaging study
Eur. J. Cardiothorac. Surg., July 1, 2007; 32(1): 102 - 107.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
W. Hassanein, A. Albert, I. Florath, Y. Y. Hegazy, U. Rosendahl, S. Bauer, and J. Ennker
Concomitant aortic valve replacement and coronary bypass: the effect of valve type on the blood flow in bypass grafts
Eur. J. Cardiothorac. Surg., March 1, 2007; 31(3): 391 - 396.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
N C Radu, E W M Kirsch, M-L Hillion, F Lagneau, L Drouet, and D Loisance
Embolic and bleeding events after modified Bentall procedure in selected patients
Heart, January 1, 2007; 93(1): 107 - 112.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
C. Nyboe, J. A. Funder, M. H. Smerup, H. Nygaard, and J. M. Hasenkam
Turbulent stress measurements downstream of three bileaflet heart valve designs in pigs.
Eur. J. Cardiothorac. Surg., June 1, 2006; 29(6): 1008 - 1013.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. Machler, M. Perthel, G. Reiter, U. Reiter, M. Zink, P. Bergmann, A. Waltensdorfer, and J. Laas
Influence of bileaflet prosthetic mitral valve orientation on left ventricular flow--an experimental in vivo magnetic resonance imaging study
Eur. J. Cardiothorac. Surg., October 1, 2004; 26(4): 747 - 753.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Kleine, M. Scherer, U. Abdel-Rahman, A. A. Klesius, H. Ackermann, and A. Moritz
Effect of mechanical aortic valve orientation on coronary artery flow: Comparison of tilting disc versus bileaflet prostheses in pigs
J. Thorac. Cardiovasc. Surg., November 1, 2002; 124(5): 925 - 932.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Kofidis, S. Fischer, R. Leyh, H. Mair, M. Deckert, R. Haberl, A. Haverich, and B. Reichart
Clinical relevance of intracranial high intensity transient signals in patients following prosthetic aortic valve replacement
Eur. J. Cardiothorac. Surg., January 1, 2002; 21(1): 22 - 26.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. G. Butchart, H.-H. Li, N. Payne, K. Buchan, and G. L. Grunkemeier
Twenty years' experience with the Medtronic Hall valve
J. Thorac. Cardiovasc. Surg., June 1, 2001; 121(6): 1090 - 1100.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.