EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Tsuyoshi Itoh
Masafumi Natsuaki
Hisao Suda
Naoki Minato
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ohtsubo, S.
Right arrow Articles by Minato, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ohtsubo, S.
Right arrow Articles by Minato, N.

Eur J Cardiothorac Surg 2000;17:420-425
© 2000 Elsevier Science NL

Successful valve-sparing in aortic root reconstruction under endoscopic guidance

Satoshi Ohtsubo, Tsuyoshi Itoh, Masafumi Natsuaki, Kojiro Furukawa, Masaru Yoshikai, Hisao Suda, Naoki Minato

Department of Thoracic and Cardiovascular Surgery, Saga Medical School, Saga, Japan

Corresponding author. Tel.: +81-952-34-2345; fax +81-952-34-2061
e-mail: ootsubt2{at}post.saga-med.ac.jp

Objective: Aortic insufficiency (AI) associated with ascending aneurysm can be corrected by valve-sparing aortic root reconstruction (‘David’ reimplantation, ‘Yacoub’ remodeling). Intraoperative endoscopic evaluation in the aortic root may help to clarify the procedure and to access competence of the preserved valve. Methods: Following cross-clamping of the ascending aorta, an endoscopy was inserted into the proximal aortic root. Perfusion of crystalloid cardioplegia enabled the visualization of the pressure-loaded valve in the closed position. Conventional macroscopic evaluation would have overlooked valve prolapse because of a release from perfusion pressure. Valve coaptation was imaged directly before and after the valve-sparing procedure. A total of 17 patients underwent aortic root reconstruction under endoscopic guidance. Indications of the valve-sparing were determined with endoscopic findings. The degree of AI before and after the surgery was evaluated by aortography and scored (0, none; 1 trivial; 2, mild; 3, moderate; 4, severe). Results: Remodeling was employed to eight patients and reimplantation to four. The other five patients were replaced with prosthetic valved-conduit. There was no early and late mortality. Before and after the valve-sparing surgery, grades of AI were significantly reduced. Three patients who underwent reimplantation procedure required late valve replacement for late progression of AI, however, none of the patients with remodeling required reoperation. Conclusion: Introduction of an endoscopy successfully reduced postoperative AI and clarified indications and limitations of valve-sparing aortic root operations.

Key Words: Aortic insufficiency • Valve-sparing • Ascending aneurysm • Endoscopy




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
H.-J. Schafers, D. Aicher, and F. Langer
Correction of leaflet prolapse in valve-preserving aortic replacement: pushing the limits?
Ann. Thorac. Surg., November 1, 2002; 74(5): S1762 - 1764.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.