|
|
||||||||
Eur J Cardiothorac Surg 2000;17:580-586
© 2000 Elsevier Science NL
a Department of Cardiothoracic Surgery, University of Gothenburg, Sahlgrenska University Hospital, SE 413 45 Gothenburg, Sweden
b Scandinavian Heart Center, Carlanderska Hospital, Gothenburg, Sweden
Corresponding author. Tel.: +46-31-342-1556; fax: +46-31-417-991
e-mail: ali.belboul{at}sahlgrenska.se
Objectives: Cardiopulmonary bypass is associated with a diffuse systemic inflammatory response that can cause considerable morbidity, including organ dysfunction and bleeding. Heparin-coated circuits have been shown to give a reduced inflammatory response with clinical benefits during open-heart surgery. However, the effects on lipid peroxidation, neutrophil activation and myocardial ischemic damage in the human have remained unknown. Methods: In a randomized single blind trial, complement activation, neutrophil counts, malondialdehyde, and cardiac enzymes were studied in 39 patients undergoing open-heart surgery. Two groups were perfused with cardiopulmonary bypass circuits with (n=20) or without heparin-coating (n=19). Results: The different complement factors (C3, C4, C3d, C3d/C3 and the C-function), neutrophil levels, MDA and the cardiac enzyme levels were comparable before CPB was started and significantly increased in both groups during bypass. There were significant intergroup differences in the neutrophil levels and MDA after reperfusion (P<0.0001). Furthermore, significant positive correlations between the lipid peroxidation, expressed as MDA levels, and the levels of neutrofils and the cardiac enzyme, CK-MB were seen within the groups. Conclusions: Heparin coated circuits did lead to a decreased neutrophil response and MDA level. The correlations between CK-MB and neutrophil and MDA levels suggest neutrophil activation leading to lipid peroxidation that may influence myocardial damage. Heparin coating improved biocompatibility and was associated with less occult myocardial ischemic damage in patients undergoing open heart surgery.
Key Words: Biocompatibility Lipid peroxidation Cardiac enzyme Heart surgery Heparin coated circuits
This article has been cited by other articles:
![]() |
O. Mangoush, S. Purkayastha, S. Haj-Yahia, J. Kinross, M. Hayward, F. Bartolozzi, A. Darzi, and T. Athanasiou Heparin-bonded circuits versus nonheparin-bonded circuits: an evaluation of their effect on clinical outcomes Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1058 - 1069. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. Jessen Pro: Heparin-Coated Circuits Should be Used for Cardiopulmonary Bypass Anesth. Analg., December 1, 2006; 103(6): 1365 - 1369. [Full Text] [PDF] |
||||
![]() |
R. Taneja and D. C. Cheng Con: Heparin-Bonded Cardiopulmonary Bypass Circuits Should Be Routine for All Cardiac Surgical Procedures Anesth. Analg., December 1, 2006; 103(6): 1370 - 1372. [Full Text] [PDF] |
||||
![]() |
S. G Raja and G. D Dreyfus Modulation of Systemic Inflammatory Response after Cardiac Surgery Asian Cardiovasc Thorac Ann, December 1, 2005; 13(4): 382 - 395. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. L. Ngaage Off-pump coronary artery bypass grafting: the myth, the logic and the science Eur. J. Cardiothorac. Surg., October 1, 2003; 24(4): 557 - 570. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Johnell, G. Elgue, R. Larsson, A. Larsson, S. Thelin, and A. Siegbahn Coagulation, fibrinolysis, and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface J. Thorac. Cardiovasc. Surg., August 1, 2002; 124(2): 321 - 332. [Abstract] [Full Text] [PDF] |
||||
![]() |
L.-C. Hsu Heparin-coated cardiopulmonary bypass circuits: current status Perfusion, September 1, 2001; 16(5): 417 - 428. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |