EJCTS Click here to go to Edwards website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Isidoro Di Bella
Carlo Banfi
Mario Viganò
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Di Bella, I.
Right arrow Articles by Viganò, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Di Bella, I.
Right arrow Articles by Viganò, M.

Eur J Cardiothorac Surg 2000;18:112-116
© 2000 Elsevier Science NL


Results with the Novacor assist system and evaluation of long-term assistance

Isidoro Di Bellaa, Francesco Pagania, Carlo Banfia, Enrico Ardemagnia, Antonio Capoa, Catherine Klersyb, Mario Viganòa

a Department of Cardiac Surgery, Policlinico San Matteo, IRCCS, Piazzale Golgi 2, 27100 Pavia, Italy
b Department of Biometry (Scientific Direction), Policlinico San Matteo, IRCCS, Piazzale Golgi 2, 27100 Pavia, Italy

Received 7 September 1999; received in revised form 28 February 2000; accepted 7 March 2000.

Corresponding author. Tel.: +39-382-503515; fax: +39-382-503059

Objective: The great number of patients awaiting heart transplant and the shortage of donors has led to the increasing use of left ventricular assist devices (LVAD) for those patients that cannot wait only on medical therapy. In this study we analyze our experience in order to evaluate the possibility of long-term assistance. Methods: We have implanted LVAD Novacor in 36 patients with a mean age of 50.4 years. They were all critical candidates for transplant on high doses of inotrops. We evaluated the clinical and hemodynamic results and studied statistically the relative risk of complications at different time intervals of support. Results: In all cases we had a statistically significant improvement of: cardiac output, wedge pressure, pulmonary vascular resistance and mean pulmonary pressure. Eleven patients died on the device, 23 underwent heart transplant and two are still on the device. Causes of death were mostly related to cerebrovascular events or multiorgan failure. Seven of the 23 patients who underwent heart transplant died with a survival rate after transplant of 69.5% and an overall survival rate of 50%. Complications occurred in 33 patients with: 24 strokes, eight TIAs, four cerebral hemorrhages, three peripheral embolisms, seven cable infections, two pocket infections, two sepsis, two major lung infections, one mediastinitis, one right ventricular failure and three multiorgan failure. Time-related analysis showed that these complications occurred mostly during the first 3 months of assistance and this is particularly true for cerebrovascular events. The incidence of infections remained constant during the follow-up period. With a mean time of assistance of 203.1 days we had only two cases of device malfunction at 662 and 1297 days. Conclusions: LVAD Novacor has provided reliable mechanical performance and good hemodynamic improvement. Most complications seem to occur in the first 90 days, therefore long-term assistance could be considered. A reduction of the high rate of thromboembolic complications remains mandatory to improve the clinical results.

Key Words: Heart failure • Heart assist device • Mechanical support • Heart transplant




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. Chumnanvej, M. J. Wood, T. E. MacGillivray, and M. F. V. Melo
Perioperative Echocardiographic Examination for Ventricular Assist Device Implantation
Anesth. Analg., September 1, 2007; 105(3): 583 - 601.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
J. G. Copeland, R. G. Smith, F. A. Arabia, P. E. Nolan, G. K. Sethi, P. H. Tsau, D. McClellan, M. J. Slepian, and the CardioWest Total Artificial Heart Investigator
Cardiac Replacement with a Total Artificial Heart as a Bridge to Transplantation
N. Engl. J. Med., August 26, 2004; 351(9): 859 - 867.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
N.E. Bowles
The molecular biology of dilated cardiomyopathy
Eur. Heart J. Suppl., December 1, 2002; 4(suppl_I): I2 - I7.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.