EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Christian Schlensak
Friedhelm Beyersdorf
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schlensak, C.
Right arrow Articles by Beyersdorf, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schlensak, C.
Right arrow Articles by Beyersdorf, F.
Related Collections
Right arrow Lung - transplantation

Eur J Cardiothorac Surg 2001;19:326-332
© 2001 Elsevier Science NL

Bronchial artery perfusion during cardiopulmonary bypass does not prevent ischemia of the lung in piglets: assessment of bronchial artery blood flow with fluorescent microspheres

Christian Schlensaka, Torsten Doensta, Stefan Preußera, Mark Wunderlicha, Manuela Kleinschmidtb, Friedhelm Beyersdorfa

a Department of Cardiovascular Surgery, University of Freiburg, Hugstetter Strasse 55, D-79106, Freiburg, Germany
b Department of Pathology, University of Freiburg, Hugstetter Strasse 55, D-79106, Freiburg, Germany

Received 15 December 1999; received in revised form 1 December 2000; accepted 30 December 2000.

Corresponding author. Tel.: +49-761-270-2818; fax: +49-761-270-2550
e-mail: schlensa{at}ch11.ukl.uni-freiburg.de

Objective: Blood supply of the lungs during total cardiopulmonary bypass (CPB) is limited to flow through the bronchial arteries. This study was undertaken to assess the bronchial artery blood flow during CPB with fluorescent microspheres in a piglet model. Methods: We subjected ten piglets (mean weight 5.0±0.5 kg) to 120 min of normothermic, total CPB without aortic cross-clamping, followed by 60 min of post-bypass perfusion. Fluorescent microspheres were injected into the left atrium or the aortic cannula or distal to the cannula to assess bronchial artery blood flow before, during and after CPB. The reference samples were taken from the descending aorta. We compared the different sites of injection. Tissue samples of the lungs were taken before and 60 min after CPB. Results: Before CPB, total bronchial artery perfusion was 43.6±14.1 ml/min (4.8±1.3% of cardiac output) as by injection distal to the aortic cannula. These values were not different when microspheres were injected into the left atrium or the aortic cannula. There was no difference in scatter or in the amount of microspheres in the reference samples among the three injections sites. During CPB, bronchial artery perfusion was significantly decreased (4.4±2.4 ml/min vs. 40.0±5.0 ml/min before CPB) and returned to baseline values 60 min after CPB. Light microscopy of the tissue samples revealed alveolar septal thickening and a decrease in alveolar surface area after 60 min of reperfusion which was associated with a decreased capacity to oxygenate blood. Conclusions: (1) Bronchial artery blood flow can quantitatively be assessed during CPB when microspheres are injected into the ascending aorta and the reference samples are taken from the descending aorta. (2) Despite adequate perfusion pressure bronchial artery blood flow is decreased substantially during CPB. (3) The decrease in blood flow and the ultrastructural changes present at the end of CPB suggest the presence of low-flow ischemia of the lung during total CPB.

Key Words: Lactate • Histology • Perfusion pressure




This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
E. M. Carvalho, E. A Gabriel, and T. A Salerno
Pulmonary Protection During Cardiac Surgery: Systematic Literature Review
Asian Cardiovasc Thorac Ann, December 1, 2008; 16(6): 503 - 507.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
E. A. Gabriel, R. Fagionato Locali, P. Katsumi Matsuoka, L. Santiago Almeida, I. Guerreiro Silva, V. L. Capelozzi, T. A. Salerno, and E. Buffolo
Lung perfusion during cardiac surgery with cardiopulmonary bypass: is it necessary?
Interactive CardioVascular and Thoracic Surgery, December 1, 2008; 7(6): 1089 - 1095.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
W. Qiu, L. Zheng, H. Gu, D. Chen, and Y. Chen
Comparison between adult and infant lung injury in a rabbit ischemia-reperfusion model.
J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 352 - 359.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Siepe, U. Goebel, A. Mecklenburg, T. Doenst, C. Benk, P. Stein, F. Beyersdorf, T. Loop, and C. Schlensak
Pulsatile Pulmonary Perfusion During Cardiopulmonary Bypass Reduces the Pulmonary Inflammatory Response
Ann. Thorac. Surg., July 1, 2008; 86(1): 115 - 122.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. Onorati, L. Cristodoro, M. Bilotta, B. Impiombato, F. Pezzo, P. Mastroroberto, A. di Virgilio, and A. Renzulli
Intraaortic balloon pumping during cardioplegic arrest preserves lung function in patients with chronic obstructive pulmonary disease.
Ann. Thorac. Surg., July 1, 2006; 82(1): 35 - 43.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
E. Fadel, E. Wijtenburg, R. Michel, J.-X. Mazoit, R. Bernatchez, B. Decante, E. Sage, M. Mazmanian, and P. Herve
Regression of the Systemic Vasculature to the Lung after Removal of Pulmonary Artery Obstruction
Am. J. Respir. Crit. Care Med., February 1, 2006; 173(3): 345 - 349.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
C. Schlensak and F. Beyersdorf
Lung injury during CPB: pathomechanisms and clinical relevance
Interactive CardioVascular and Thoracic Surgery, October 1, 2005; 4(5): 381 - 382.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. E. Karaiskos, G. M. Palatianos, C. D. Triantafillou, G. H. Kantidakis, G. M. Astras, E. G. Papadakis, and M. I. Vassili
Clinical Effectiveness of Leukocyte Filtration During Cardiopulmonary Bypass in Patients with Chronic Obstructive Pulmonary Disease
Ann. Thorac. Surg., October 1, 2004; 78(4): 1339 - 1344.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. M. Dodd-o, L. E. Welsh, J. D. Salazar, P. L. Walinsky, E. A. Peck, J. G. Shake, D. J. Caparrelli, B. T. Bethea, S. M. Cattaneo, W. A. Baumgartner, et al.
Effect of bronchial artery blood flow on cardiopulmonary bypass-induced lung injury
Am J Physiol Heart Circ Physiol, February 1, 2004; 286(2): H693 - H700.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. Schlensak, T. Doenst, S. Preu{beta}er, M. Wunderlich, M. Kleinschmidt, and F. Beyersdorf
Cardiopulmonary bypass reduction of bronchial blood flow: A potential mechanism for lung injury in a neonatal pig model
J. Thorac. Cardiovasc. Surg., June 1, 2002; 123(6): 1199 - 1205.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.