|
|
||||||||
Eur J Cardiothorac Surg 2001;19:326-332
© 2001 Elsevier Science NL
a Department of Cardiovascular Surgery, University of Freiburg, Hugstetter Strasse 55, D-79106, Freiburg, Germany
b Department of Pathology, University of Freiburg, Hugstetter Strasse 55, D-79106, Freiburg, Germany
Received 15 December 1999; received in revised form 1 December 2000; accepted 30 December 2000.
Corresponding author. Tel.: +49-761-270-2818; fax: +49-761-270-2550
e-mail: schlensa{at}ch11.ukl.uni-freiburg.de
Objective: Blood supply of the lungs during total cardiopulmonary bypass (CPB) is limited to flow through the bronchial arteries. This study was undertaken to assess the bronchial artery blood flow during CPB with fluorescent microspheres in a piglet model. Methods: We subjected ten piglets (mean weight 5.0±0.5 kg) to 120 min of normothermic, total CPB without aortic cross-clamping, followed by 60 min of post-bypass perfusion. Fluorescent microspheres were injected into the left atrium or the aortic cannula or distal to the cannula to assess bronchial artery blood flow before, during and after CPB. The reference samples were taken from the descending aorta. We compared the different sites of injection. Tissue samples of the lungs were taken before and 60 min after CPB. Results: Before CPB, total bronchial artery perfusion was 43.6±14.1 ml/min (4.8±1.3% of cardiac output) as by injection distal to the aortic cannula. These values were not different when microspheres were injected into the left atrium or the aortic cannula. There was no difference in scatter or in the amount of microspheres in the reference samples among the three injections sites. During CPB, bronchial artery perfusion was significantly decreased (4.4±2.4 ml/min vs. 40.0±5.0 ml/min before CPB) and returned to baseline values 60 min after CPB. Light microscopy of the tissue samples revealed alveolar septal thickening and a decrease in alveolar surface area after 60 min of reperfusion which was associated with a decreased capacity to oxygenate blood. Conclusions: (1) Bronchial artery blood flow can quantitatively be assessed during CPB when microspheres are injected into the ascending aorta and the reference samples are taken from the descending aorta. (2) Despite adequate perfusion pressure bronchial artery blood flow is decreased substantially during CPB. (3) The decrease in blood flow and the ultrastructural changes present at the end of CPB suggest the presence of low-flow ischemia of the lung during total CPB.
Key Words: Lactate Histology Perfusion pressure
This article has been cited by other articles:
![]() |
E. M. Carvalho, E. A Gabriel, and T. A Salerno Pulmonary Protection During Cardiac Surgery: Systematic Literature Review Asian Cardiovasc Thorac Ann, December 1, 2008; 16(6): 503 - 507. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. A. Gabriel, R. Fagionato Locali, P. Katsumi Matsuoka, L. Santiago Almeida, I. Guerreiro Silva, V. L. Capelozzi, T. A. Salerno, and E. Buffolo Lung perfusion during cardiac surgery with cardiopulmonary bypass: is it necessary? Interactive CardioVascular and Thoracic Surgery, December 1, 2008; 7(6): 1089 - 1095. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Qiu, L. Zheng, H. Gu, D. Chen, and Y. Chen Comparison between adult and infant lung injury in a rabbit ischemia-reperfusion model. J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 352 - 359. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Siepe, U. Goebel, A. Mecklenburg, T. Doenst, C. Benk, P. Stein, F. Beyersdorf, T. Loop, and C. Schlensak Pulsatile Pulmonary Perfusion During Cardiopulmonary Bypass Reduces the Pulmonary Inflammatory Response Ann. Thorac. Surg., July 1, 2008; 86(1): 115 - 122. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Onorati, L. Cristodoro, M. Bilotta, B. Impiombato, F. Pezzo, P. Mastroroberto, A. di Virgilio, and A. Renzulli Intraaortic balloon pumping during cardioplegic arrest preserves lung function in patients with chronic obstructive pulmonary disease. Ann. Thorac. Surg., July 1, 2006; 82(1): 35 - 43. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Fadel, E. Wijtenburg, R. Michel, J.-X. Mazoit, R. Bernatchez, B. Decante, E. Sage, M. Mazmanian, and P. Herve Regression of the Systemic Vasculature to the Lung after Removal of Pulmonary Artery Obstruction Am. J. Respir. Crit. Care Med., February 1, 2006; 173(3): 345 - 349. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Schlensak and F. Beyersdorf Lung injury during CPB: pathomechanisms and clinical relevance Interactive CardioVascular and Thoracic Surgery, October 1, 2005; 4(5): 381 - 382. [Full Text] [PDF] |
||||
![]() |
T. E. Karaiskos, G. M. Palatianos, C. D. Triantafillou, G. H. Kantidakis, G. M. Astras, E. G. Papadakis, and M. I. Vassili Clinical Effectiveness of Leukocyte Filtration During Cardiopulmonary Bypass in Patients with Chronic Obstructive Pulmonary Disease Ann. Thorac. Surg., October 1, 2004; 78(4): 1339 - 1344. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Dodd-o, L. E. Welsh, J. D. Salazar, P. L. Walinsky, E. A. Peck, J. G. Shake, D. J. Caparrelli, B. T. Bethea, S. M. Cattaneo, W. A. Baumgartner, et al. Effect of bronchial artery blood flow on cardiopulmonary bypass-induced lung injury Am J Physiol Heart Circ Physiol, February 1, 2004; 286(2): H693 - H700. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Schlensak, T. Doenst, S. Preu{beta}er, M. Wunderlich, M. Kleinschmidt, and F. Beyersdorf Cardiopulmonary bypass reduction of bronchial blood flow: A potential mechanism for lung injury in a neonatal pig model J. Thorac. Cardiovasc. Surg., June 1, 2002; 123(6): 1199 - 1205. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |