EJCTS Click here to locate an Ethicon representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Saito, S.
Right arrow Articles by Nojiri, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Saito, S.
Right arrow Articles by Nojiri, C.
Related Collections
Right arrow Mechanical Circulatory Assistance

Eur J Cardiothorac Surg 2001;19:678-683
© 2001 Elsevier Science NL

Reliable long-term non-pulsatile circulatory support without anticoagulation

S. Saitoa, S. Westabya, D. Piggotta, T. Katsumataa, S. Dudnikova, D. Robsona, P. Catarinoa, C. Nojirib

a Oxford Heart Centre, John Radcliffe Hospital, Headley Way, Headington, Oxford OX3 9DU, UK
b Terumo R&D Centre, Kanagawa, Japan

Received 10 October 2000; received in revised form 2 February 2001; accepted 23 February 2001.

Corresponding author. Tel.: +44-1865-220269; fax: +44-1865-220268
e-mail: swestaby{at}ahf.org.uk

Objective: The Terumo implantable left ventricular assist system (T-ILVAS) consists of a titanium centrifugal pump with a unique magnetically suspended impeller producing continuous (non-pulsatile) flow up to 10 l/min. The interior surface is heparin-coated and there is no purge system. We implanted the device into six sheep to ascertain in-vivo haemodynamic function, mechanical reliability and biocompatibility. Methods: The T-ILVAS was implanted via left thoracotomy without cardiopulmonary bypass. The inflow cannula was placed in the left ventricular apex and a Dacron outflow graft anastomosed to the descending aorta. All animals recovered well. No anticoagulation (heparin or warfarin) was given after the surgery. Suspension position, motor current, impeller speed and pump flow were continuously monitored and stored by on-line computer. Serial blood samples were collected to determine haematological and biochemical indices of renal function, liver function and haemolysis. All animals were electively euthanized between 3 and 7 months postoperatively. The explanted pumps were examined for mechanical reliability and thrombus formation. Major organs were examined macroscopically and histologically for thromboembolism. Results: All animals appeared completely normal for up to 210 days. At speeds between 1500 and 2000 rev./min the device pumped up to 8 l/min capturing all mitral flow. There were no major complications (pump failure, thromboembolism, haemorrhage, or driveline infection). Indices of haemolysis, liver and renal function remained within normal limits. All pumps were mechanically sound and free from thrombus. One embolus was found in a sectioned kidney. Conclusion: The T-ILVAS successfully supported the systemic circulation without anticoagulation for up to 210 days. Mechanical reliability and biocompatibility were demonstrated. Organ function remained within normal limits during continuous non-pulsatile flow.

Key Words: Left ventricular assist device • Centrifugal pump • Sheep




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Ootaki, K. Kamohara, M. Akiyama, F. Zahr, M. W. Kopcak Jr., R. Dessoffy, and K. Fukamachi
Phasic coronary blood flow pattern during a continuous flow left ventricular assist support
Eur. J. Cardiothorac. Surg., November 1, 2005; 28(5): 711 - 716.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
C. H. Huber, P. Tozzi, M. Hurni, and L. K. von Segesser
No drive line, no seal, no bearing and no wear: magnetics for impeller suspension and flow assessment in a new VAD
Interactive CardioVascular and Thoracic Surgery, June 1, 2004; 3(2): 336 - 340.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. J. Goldstein
Worldwide Experience With the MicroMed DeBakey Ventricular Assist Device(R) as a Bridge to Transplantation
Circulation, September 9, 2003; 108(90101): II-272 - 277.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Saito, S. Westaby, D. Piggot, S. Dudnikov, D. Robson, P. A. Catarino, C. Clelland, and C. Nojiri
End-organ function during chronic nonpulsatile circulation
Ann. Thorac. Surg., October 1, 2002; 74(4): 1080 - 1085.
[Abstract] [Full Text] [PDF]


Home page
ScienceHome page
P. M. McCarthy and W. A. Smith
Mechanical Circulatory Support--a Long and Winding Road
Science, February 8, 2002; 295(5557): 998 - 999.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.