|
|
||||||||
Eur J Cardiothorac Surg 2001;19:797-805
© 2001 Elsevier Science NL
a Division of Cardiac Surgery, Karl Franzens University and Medical School of Graz, Graz, Austria
b Division of Radiology, EBT, Karl Franzens University and Medical School of Graz, Graz, Austria
c Division of Cardiology, Karl Franzens University and Medical School of Graz, Graz, Austria
d Division of Biomedical Engineering and Computing, Karl Franzens University and Medical School of Graz, Graz, Austria
Received 11 October 2000; received in revised form 8 March 2001; accepted 13 March 2001.
Corresponding author. Tel.: +43-316-385-4671; fax: +43-316-385-4672
e-mail: igor.knez{at}kfunigraz.ac.at
Objectives: Left ventricular hypertrophy in patients with critical aortic stenosis (AS) is an adaptive process that compensates for high intracavitary pressure and reduces systolic wall stress followed by an increase in myocardial masses. In the present prospective clinical trial, we investigated long-term compensatory changes in left ventricular geometry and function after aortic valve replacement using mechanical bileaflet prostheses with the main emphasis on the small-sized aortic annulus and valve prosthesispatient mismatch. Methods: A total of 58 patients with critical AS were assigned to the following groups according to the predictive value of prosthetic valve area index (VAI): group EXMIS: 29 patients (VAI
0.99), expected mismatch; group NOMIS: 29 patients (VAI
0.99), no mismatch. At controls T0 (before operation/operation (OP), T1 and T2 (4 and 20 months after OP) the left ventricular geometry was recorded by means of Imatron® electron beam tomography and the transprosthetic velocities were measured by echocardiography. Results: Statistical analysis showed a consistent reduction in the absolute (P=0.04) and indexed (P=0.04) left ventricular myocardial mass for both cohorts; furthermore, there was a significant difference between EXMIS and NOMIS patients concerning the factors, time and mass reduction (P=0.005), because of distinct baselines. A logistic regression report revealed preoperative cardiac output, absolute left ventricular myocardial mass, perfusion, body surface area and the native valve orifice area as predicting coefficients and factors for a minimum mass reduction of 25%. We explain a mathematical formula that turned out to be the most sensitive for correctly classified factors. Conclusions: The left ventricular geometry and transprosthetic velocities resulted in the same postoperative recovery for both EXMIS and NOMIS patients. The presented data showed that valve prosthesispatient mismatch had no influence in several stepwise logistic regression models. We conclude that modern mechanical bileaflet prostheses allow both acceptable hemodynamics and recovery of left ventricular hypertrophy, even in small aortic annuli.
Key Words: Aortic valve replacement Regression of left ventricular myocardial mass Valve area index Effective valve orifice area Mechanical bileaflet prosthesis
This article has been cited by other articles:
![]() |
S. Bleiziffer, W. B Eichinger, I. Hettich, R. Guenzinger, D. Ruzicka, R. Bauernschmitt, and R. Lange Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? Heart, May 1, 2007; 93(5): 615 - 620. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Chatel, C. Mica, D. Blanchard, F. Baud, D. Bruere, A. Maudiere, and P. Peycher Short-term hemodynamic advantages of stentless CryoLife-O'Brien valve over stented bioprostheses for aortic valve replacement Interactive CardioVascular and Thoracic Surgery, October 1, 2006; 5(5): 578 - 580. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Pibarot and J G Dumesnil Prosthesis-patient mismatch: definition, clinical impact, and prevention Heart, August 1, 2006; 92(8): 1022 - 1029. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Dumesnil and P. Pibarot Prosthesis-patient mismatch and clinical outcomes: The evidence continues to accumulate J. Thorac. Cardiovasc. Surg., May 1, 2006; 131(5): 952 - 955. [Full Text] [PDF] |
||||
![]() |
M. Ruel, H. Al-Faleh, A. Kulik, K. L. Chan, T. G. Mesana, and I. G. Burwash Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction: Effect on survival, freedom from heart failure, and left ventricular mass regression J. Thorac. Cardiovasc. Surg., May 1, 2006; 131(5): 1036 - 1044. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Tasca, Z. Mhagna, S. Perotti, P. B. Centurini, T. Sabatini, A. Amaducci, F. Brunelli, M. Cirillo, M. D. Tomba, E. Quiani, et al. Impact of Prosthesis-Patient Mismatch on Cardiac Events and Midterm Mortality After Aortic Valve Replacement in Patients With Pure Aortic Stenosis Circulation, January 31, 2006; 113(4): 570 - 576. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Tasca, F. Brunelli, M. Cirillo, M. Dalla Tomba, Z. Mhagna, G. Troise, and E. Quaini Impact of the Improvement of Valve Area Achieved With Aortic Valve Replacement on the Regression of Left Ventricular Hypertrophy in Patients With Pure Aortic Stenosis Ann. Thorac. Surg., April 1, 2005; 79(4): 1291 - 1296. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ruel, F. D. Rubens, R. G. Masters, A. L. Pipe, P. Bedard, P. J. Hendry, B. K. Lam, I. G. Burwash, W. G. Goldstein, M. P. Brais, et al. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves J. Thorac. Cardiovasc. Surg., January 1, 2004; 127(1): 149 - 159. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Knez, P. R. Vogt, P. Rehak, and B. Rigler Changes in the current approach do not qualify prosthesis-patient mismatch either (reply to Dumesnil et al., EJCTS 2002;21:157-158) Eur. J. Cardiothorac. Surg., April 1, 2002; 21(4): 769 - 770. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |