European Journal of Cardio-Thoracic Surgery, Vol 2, 143-150, Copyright © 1988 by European Association for Cardio-thoracic Surgery
KJ MacArthur, WH Bain, MA Turner, KG Davidson, GA Berg, S Nashef and R Rodger
Between January 1977 and December 1986, 1606 Bjork-Shiley tilting disc
prostheses (BS) and 1346 Carpentier Edwards porcine prostheses (CE) were
implanted in 1300 and 1156 patients, respectively, at the same institution.
During the time of implantation, both valves have developed: the BS through
standard disc and convexo-concave to monostrut, and the CE valves from
standard to supra-annular. Newer valve types were used where applicable as
they became available. Preoperative status in respect of age and cardiac
rhythm were similar. There were significantly more females (64% BS: 54% CE,
P less than 0.001); worse NYHA grade (74% Grade 111 and IV-BS: 56% 111 and
IV-CE, P less than 0.001) more closed heart surgery (26% BS: 18% CE, P less
than 0.001) and more previous open heart surgery (11.6% BS: 8.9% CE, P less
than 0.001) in the BS group. All BS patients were anticoagulated and 49% of
mitral CE patients and 7% of aortic CE patients were anticoagulated. There
was no significant difference between the two groups in hospital mortality
(BS 7.2%: CE 6.3%), late mortality (BS 2.5%/patient year: CE 3.2%/patient
year) overall incidence of systemic embolism (BS 1.3%/patient year: CE
1.4/patient year), prosthetic valve endocarditis (BS 0.7%/patient year: CE
0.9%/patient year), valve failure (BS 0.5%/patient year: CE 0.9%/patient
year) or peri-prosthetic leak (BS 1.2%/patient year: CE 1.3%/patient year).
The incidence of systemic embolism in the aortic position was lower with
the BS prosthesis (BS 0.2%/patient year: CE 1.2%/patient year, P less than
0.02).(ABSTRACT TRUNCATED AT 250 WORDS)
ARTICLES
Mechanical versus biological heart valves: a ten-year comparison in a single centre
Department of Cardiac Surgery, Western Infirmary, Glasgow, UK.
This article has been cited by other articles:
![]() |
D. D. Glower, W. D. White, A. C. Hatton, L. R. Smith, W. G. Young, W. G. Wolfe, and J. E. Lowe Determinants of reoperation after 960 valve replacements with Carpentier-Edwards prostheses J. Thorac. Cardiovasc. Surg., February 1, 1994; 107(2): 381 - 393. [Abstract] [Full Text] |
||||
![]() |
K. E. Hammermeister, G. K. Sethi, W. G. Henderson, C. Oprian, T. Kim, S. Rahimtoola, and The Veterans Affairs Cooperative Study on Valvular A Comparison of Outcomes in Men 11 Years after Heart-Valve Replacement with a Mechanical Valve or Bioprosthesis N. Engl. J. Med., May 6, 1993; 328(18): 1289 - 1296. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |