EJCTS Click here to locate an Ethicon representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gallo, I.
Right arrow Articles by Artinano, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gallo, I.
Right arrow Articles by Artinano, E.

European Journal of Cardio-Thoracic Surgery, Vol 2, 273-281, Copyright © 1988 by European Association for Cardio-thoracic Surgery


ARTICLES

Long-term performance of porcine heart valve bioprostheses

I Gallo, F Nistal, R Cayon, E Arbe, R Blasquez and E Artinano
Department of Cardiovascular Surgery, Hospital Nacional Marques de Valdecilla, University of Cantabria, Santander, Spain.

To assess the results after long-term implantation of porcine bioprosthetic heart valves, 320 patients with 381 valves were retrospectively reviewed. This group included all patients receiving one such xenograft in the mitral or aortic position (or both) in our institution between June 1974 and December 1976. The patients had a follow-up of 9-11.5 years. Actuarial patient survival rats (hospital mortality excluded) were 85%-90% at 6 years and 68%-79% at 11.5 years. Thromboembolic episodes did not show any significant clustering over the first weeks or months, in fact, they appeared at a constant rate. Actuarial rates of freedom from thromboembolism were greater than 90% for aortic patients at 11.5 years and greater than 80% for mitral and mitroaortic patients at 11.5 years. The linearized rate of anticoagulant-related haemorrhage for the whole group of patients was 0.4 events/100 patient years with a related mortality of 0.2 events/100 patient years. Prosthetic valve endocarditis and paravalvular leak appeared at linearized rates of 0.6 (0.1 of related mortality) and 0.4 (0.1 of related mortality) events/100 patient years. Primary tissue valve failure constituted the most prevalent complication (82 cases) in the long term but did not significantly worsen patient survival. Actuarial rates of freedom from primary tissue failure were 91% +/- 2% at 6, and 40% +/- 14% at 11.5 years for mitral valves, and 95% +/- 4% at 6 and 64% +/- 6% at 11.5 years for aortic valves.(ABSTRACT TRUNCATED AT 250 WORDS)





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1988 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.