EJCTS Click here to go to Edwards website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aitchison, J.D.
Right arrow Articles by Dark, J.H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aitchison, J.D.
Right arrow Articles by Dark, J.H.
Related Collections
Right arrow Lung - transplantation
Right arrow Transplantation - heart

Eur J Cardiothorac Surg 2001;20:187-194
© 2001 Elsevier Science NL

Functional assessment of non-heart-beating donor lungs: prediction of post-transplant function

J.D. Aitchisona, H.E. Orrb, P.A. Flecknellb, J.A. Kirbya, J.H. Darka

a Department of Surgery, University of Newcastle upon Tyne, Framlington Place, Newcastle upon Tyne, NE2 4HH, UK
b Comparative Biology Centre, University of Newcastle upon Tyne, Framlington Place, Newcastle upon Tyne, NE2 4HH, UK

Received 10 October 2000; received in revised form 12 March 2001; accepted 30 March 2001.

Corresponding author. William Leech Centre, Freeman Hospital, High Heaton, Newcastle upon Tyne, NE7 7DN, UK. Tel.: +44-191-284-3111, ext. 26169; fax: +44-191-223-1152
e-mail: j.d.aitchison{at}ncl.ac.uk

Objectives: To enable an increase in the numbers of donor lungs using organs from non-heart-beating donors (NHBD). To develop an isolated ventilation and perfusion technique to assess the degree of warm ischaemic organ injury suffered prior to retrieval, thereby enabling identification of lungs with predictably good post-transplant function. Methods: Lungs from Landrace–Yorkshire White cross pigs were retrieved after 1 (NHBD1), 2 (NHBD2) or 4 h (NHBD4) post-hypoxic death induced by cessation of ventilation. Control organs were retrieved using standard techniques for each group from matched animals immediately following aortic cross-clamping (Control1 and combined Control2,4). Modified Euro–Collins pulmoplegia was used in all groups, prior to ventilating a single lung with 100% oxygen and perfusion with neutrophil-depleted and deoxygenated blood. For all of the lungs in the NHBD2 and combined Control2,4 groups, and one of the successfully perfused NHBD4, the contralateral lung was then transplanted with post-transplant function assessed for 12 h. All animals were anaesthetized throughout and euthanased without regaining consciousness. Results: On assessment, oxygenation after 5 min of perfusion did not differ between NHBD1 (n=4) vs. Control1 (n=5; analysis of variance (ANOVA), P=0.152). However, oxygenation had deteriorated significantly in the NHBD2 group (n=6) vs. Control2,4 (n=8; ANOVA, P<0.0005) and was significantly poorer than initial values after 8 min (unpaired t-test with Bonferroni correction, P<0.03). In NHBD4 (n=6), four lungs failed assessment due to the development of gross pulmonary oedema, although the remaining pair functioned as well as Control2,4. Post-transplantation, NHBD2 (n=6) contralateral lungs showed significantly poorer overall oxygenation, (mean±SD, 46±22 kPa) when compared with Control2,4 (n=6; 59±16 kPa; ANOVA, P=0.001), although oxygenation was satisfactory. The contralateral organ from one successfully perfused NHBD4 lung functioned well post-transplantation. Conclusions: The significant deterioration in oxygenating performance seen during assessment after 2 h warm ischaemia and the idiosyncratic function after 4 h warm ischaemia indicates the importance of functional testing of NHBD lungs. The similar deterioration in oxygenating performance seen post-transplantation in the contralateral lungs suggests that this method detects functional warm ischaemic lung injury.

Key Words: Lung transplantation • Non-heart-beating donor • Isolated perfusion • Animal




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
H. Inokawa, M. Sevala, W. K. Funkhouser, and T. M. Egan
Ex-vivo perfusion and ventilation of rat lungs from non-heart-beating donors before transplant.
Ann. Thorac. Surg., October 1, 2006; 82(4): 1219 - 1225.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. M. Egan, J. A. Haithcock, W. A. Nicotra, G. Koukoulis, H. Inokawa, M. Sevala, P. L. Molina, W. K. Funkhouser, and B. J. Mattice
Ex Vivo Evaluation of Human Lungs for Transplant Suitability
Ann. Thorac. Surg., April 1, 2006; 81(4): 1205 - 1213.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
D. S. Wilkes, T. M. Egan, and H. Y. Reynolds
Lung Transplantation: Opportunities for Research and Clinical Advancement
Am. J. Respir. Crit. Care Med., October 15, 2005; 172(8): 944 - 955.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
F. R Rega, E. J Vandezande, N. C Jannis, G. M Verleden, T. E Lerut, and D. E. Van Raemdonck
The role of leukocyte depletion in ex vivo evaluation of pulmonary grafts from (non-)heart-beating donors
Perfusion, January 1, 2003; 18(1_suppl): 13 - 21.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.