EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ni, Y.-m.
Right arrow Articles by von Segesser, L. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ni, Y.-m.
Right arrow Articles by von Segesser, L. K.
Related Collections
Right arrow Extracorporeal circulation

Eur J Cardiothorac Surg 2001;20:614-620
© 2001 Elsevier Science NL

Optimization of venous return tubing diameter for cardiopulmonary bypass

Yi-ming Nia, Boris Leskosekb, Li-ping Shia, Ying-lian Chena, Lin-feng Qiana, Ren-yuan Lia, Zheng-liang Tua, Ludwig K. von Segesserc

a Department of Cardiothoracic Surgery, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou, China
b Department for Cardiovascular Surgery, University Hospital, Zurich, Switzerland
c Department for Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, CH-1011 Lausanne, Switzerland

Received 21 February 2001; received in revised form 14 May 2001; accepted 31 May 2001.

Corresponding author. Tel.: +41-21-314-2280; fax: +41-21-314-2278
e-mail: ludwig.von-segesser{at}chuv.hospvd.ch

Objective: To determine the optimal venous tubing diameter for adult cardiopulmonary bypass (CPB) to improve gravity drainage and to reduce priming volume. Methods: (A) Maximum bovine blood flow rates by gravity drainage were assessed in vitro for four different tubing diameters (1/2, 3/8, 5/16,1/4 inch) with three different lengths and various pre- and afterloads. Based on the results of (A) and multiple regression analyses, we developed equations to predict tubing sizes as a function of target flows. (C) The equations obtained in (B) were validated by ex vivo bovine experiments. (D) The clinically required maximal flows were determined retrospectively by reviewing 119 perfusion records at Zurich University. (E) Based on our model (B), the clinical patient and hardware requirements, the optimal venous tubing diameter was calculated. (F) The optimized venous tubing was evaluated in a prospective clinical trial involving 312 patients in Hangzhou. Results: For a mean body surface area of 1.83±0.2 m2, the maximal perfusion flow rate (D) achieved with 1/2-inch (=1.27 cm2) venous tubing was 4.62±0.57 l/min (range: 2.50–6.24 l/min). Our validated model (B,C) predicted 1.0 cm2 as optimal cross-sectional area for the venous line. New tubing packs developed accordingly were used routinely thereafter. The maximal flow rate was 4.93±0.58 l/min (range: 3.9–7.0) in patients with a mean body surface area of 1.62±0.21 m2. Conclusion: The new venous tubing with 1.0-cm2 cross-sectional area improves the drainage in the vast majority of adult patients undergoing CPB and reduces the priming volume (-27 ml/m). Reduced hemodilution can prevent homologous transfusions if a predefined transfusion trigger level is not reached.

Key Words: Cardiopulmonary bypass • Gravity drainage • Venous line • Priming volume • Extracorporeal circulation




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
L. K. von Segesser, M. Kalejs, E. Ferrari, S. Bommeli, O. Maunz, J. Horisberger, and P. Tozzi
Superior flow for bridge to life with self-expanding venous cannulas
Eur. J. Cardiothorac. Surg., October 1, 2009; 36(4): 665 - 669.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
L. K. von Segesser, G. Siniscalchi, K. Kang, O. Maunz, J. Horisberger, E. Ferrari, D. Delay, and P. Tozzi
Temporary caval stenting improves venous drainage during cardiopulmonary bypass
Interactive CardioVascular and Thoracic Surgery, December 1, 2008; 7(6): 1096 - 1100.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
L. K. von Segesser, E. Ferrari, D. Delay, O. Maunz, J. Horisberger, and P. Tozzi
Routine use of self-expanding venous cannulas for cardiopulmonary bypass: benefits and pitfalls in 100 consecutive cases
Eur. J. Cardiothorac. Surg., September 1, 2008; 34(3): 635 - 640.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
S Abdel-Sayed, J Favre, J Horisberger, S Taub, D Hayoz, and L. von Segesser
New bench test for venous cannula performance assessment
Perfusion, November 1, 2007; 22(6): 411 - 416.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. F. Corno
Systemic venous drainage: can we help Newton?
Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1044 - 1051.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
L. K. von Segesser, P. Tozzi, E. Riccardo Ferrari, C. Huber, D. Delay, D. Jegger, and J. Horisberger
Small access (30F) clinical central venous smart cannulation: is it adequate?
Interactive CardioVascular and Thoracic Surgery, October 1, 2006; 5(5): 540 - 543.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
L. K von Segesser, P. Tozzi, I. Mallbiabrrena, D. Jegger, J. Horisberger, and A. Corno
Miniaturization in cardiopulmonary bypass
Perfusion, July 1, 2003; 18(4): 219 - 224.
[Abstract] [PDF]


Home page
PerfusionHome page
D. Jegger, A. F Corno, A. Mucciolo, G. Mucciolo, Y. Boone, J. Horisberger, I. Seigneul, M. Jachertz, and L. K von Segesser
A prototype paediatric venous cannula with shape change in situ
Perfusion, January 1, 2003; 18(1): 61 - 65.
[Abstract] [PDF]


Home page
ICVTSHome page
X. M. Mueller, I. Mallabiabrena, G. Mucciolo, and L. K. von Segesser
Optimized venous return with a self-expanding cannula: from computational fluid dynamics to clinical application
Interactive CardioVascular and Thoracic Surgery, September 1, 2002; 1(1): 23 - 27.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
X. M. Mueller, D. Jegger, M. Augstburger, J. Horisberger, G. Godar, and L. K. von Segesser
A new concept of integrated cardiopulmonary bypass circuit
Eur. J. Cardiothorac. Surg., May 1, 2002; 21(5): 840 - 846.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.