|
|
||||||||
Eur J Cardiothorac Surg 2002;21:36-40
© 2002 Elsevier Science NL
lu
luDepartment of Cardiovascular Surgery, Ankara University Faculty of Medicine Hospital, Ankara, Turkey
Received 9 July 2001; received in revised form 18 October 2001; accepted 18 October 2001.
* Corresponding author. Tel.: +90-532-203-8253; fax: +90-312-312-2103
e-mail: sadikeryilmaz{at}hotmail.com
Objective: The purpose of this study is to report our experience in off-pump coronary artery surgery in patients who have left ventricular dysfunction. Methods: Off-pump coronary artery surgery was performed to 48 patients who were chosen randomly among 265 patients having two or more coronary artery disease and whose ejection fraction (EF) was less than 30%. In these patients fractioned shortening (FS) was evaluated by echocardiography, EF with multiple gated acquisition (MUGA) and ischaemic regions with myocardial perfusion scintigraphy both pre- and postoperatively. Coronary artery angiography was done to all patients at the end of the 1st year and patients were evaluated according to New York Heart Association (NYHA) classification. Results: There were three deaths. The clinical situations of 41 of 45 patients (91.1%) improved after the operation. These four patients who didn't improve in NYHA status were the ones in whom complete revascularization couldn't be done. The FS and EF values were significantly increased at the 1st month, and 1st year. The constant perfusion defects and irreversible damaged areas changed into dynamic myocardial tissue in the 1st year scintigraphies. Discussion: Off-pump CABG can be done with an acceptable mortality and clinic results in patients who have ventricular dysfunction.
Key Words: Off-pump CABG Left ventricular dysfunction
This article has been cited by other articles:
![]() |
M. Masoumi, M. R Saidi, F. Rostami, H. Sepahi, and D. Roushani Off-Pump Coronary Artery Bypass Grafting in Left Ventricular Dysfunction Asian Cardiovasc Thorac Ann, February 1, 2008; 16(1): 16 - 20. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hilker, H. Oelert, and U. Hake A review of 507 off-pump coronary bypass patients: a single center experience Interactive CardioVascular and Thoracic Surgery, September 1, 2003; 2(3): 246 - 250. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Al-Ruzzeh, T. Athanasiou, S. George, B. E. Glenville, A. C. DeSouza, J. R. Pepper, and M. Amrani Is the use of cardiopulmonary bypass for multivessel coronary artery bypass surgery an independent predictor of operative mortality in patients with ischemic left ventricular dysfunction? Ann. Thorac. Surg., August 1, 2003; 76(2): 444 - 451. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Ascione, M. Caputo, and G. D. Angelini Off-pump coronary artery bypass grafting: not a flash in the pan Ann. Thorac. Surg., January 1, 2003; 75(1): 306 - 313. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |