EJCTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Isaac Kadir
Alan J. Bryan
Gianni D. Angelini
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kadir, I.
Right arrow Articles by Angelini, G. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kadir, I.
Right arrow Articles by Angelini, G. D.
Related Collections
Right arrow Valve disease

Eur J Cardiothorac Surg 2002;21:692-697
© 2002 Elsevier Science NL

Comparison of exercise and dobutamine echocardiography in the haemodynamic assessment of small size mechanical aortic valve prostheses

Isaac Kadir, Catherine Walsh, Peter Wilde, Alan J. Bryan, Gianni D. Angelini*

Bristol Heart Institute and Department of Clinical Radiology, University of Bristol, Bristol, UK

Received 2 October 2001; received in revised form 15 January 2002; accepted 28 January 2002.

* Corresponding author. Tel.: +44-0117-928-3145; fax: +44-0117-929-9737
e-mail: g.d.angelini{at}bristol.ac.uk

Objective: Doppler echocardiographic evaluation of prosthetic heart valve function is usually performed at rest although this situation is not representative of patients' daily activities. Following aortic valve replacement, patients most likely to remain symptomatic are those with a small aortic root and dobutamine or exercise echocardiography has been proposed to elicit the presence of abnormal haemodynamics or persistently elevated transvalvular gradients in these patients. This study was carried out to compare dobutamine echocardiography with a symptom limited treadmill exercise echocardiography in patients following aortic valve replacement with a small size (19 mm) St. Jude Mechanical valve prosthesis. Methods: The study population consisted of ten unselected patients following aortic valve replacement. Dobutamine was infused intravenously starting at 5 µg/kg/min and increasing by 5 µg/kg/min at 15 min interval up to 20 µg/kg/min. Heart rate, blood pressure, cardiac output (CO), peak and mean gradients as well as effective orifice area (EOA) were measured. These parameters were also measured following a symptom limited treadmill exercise. Results: Dobutamine stress increased heart rate (HR) and CO by 50 and 74%, respectively (both P<0.0002), and mean transvalvular gradient from 22±4.1 mmHg at rest to 40.0±10 mmHg at maximum stress (P<0.001). With exercise, HR and CO increased by 48 and 70%, respectively while mean transvalvular gradient increased from 22±3.1 mmHg at rest to 38.0±6.4 mmHg (P<0.0001). The maximum increase in HR, CO and mean transvalvular gradient with dobutamine and exercise were similar however. There was no significant change in the EOA with either dobutamine or exercise. Conclusion: The result suggests that both treadmill exercise and dobutamine stress echocardiography are equally effective for the hemodynamic evaluation of small aortic valve prosthesis.

Key Words: Exercise echocardiography • Dobutamine echocardiography • Small size aortic valve prosthesis







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.