EJCTS Click here to go to Edwards website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Borman, J.B.
Right arrow Articles by De Riberolles, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Borman, J.B.
Right arrow Articles by De Riberolles, C.
Related Collections
Right arrow Valve disease

Eur J Cardiothorac Surg 2003;23:86-92
© 2003 Elsevier Science NL


Sorin BicarbonTM bileaflet valve: a 10-year experience

J.B. Borman*, C. De Riberolles

Hadassah University Hospital, Cardiac Surgery Research Center, P.O. Box 12000, Jerusalem 91120, Israel

Received 25 June 2002; received in revised form 27 August 2002; accepted 1 October 2002.

* Corresponding author. Tel.: +972-2-6776-790; fax: +972-2-6780-927
e-mail: jbborman{at}netvision.net.il

Objective: To present a large 10 year experience of a collaborative evaluation of the Sorin Bicarbon (SB) mechanical prosthesis carried out in 14 centers in eight Western European countries. Methods: Between 4/90 and 12/96, 2078 SB valves were implanted in 1875 patients aged 4–84 years (mean 58), 1108 males and 767 females. The valves inserted were 1026 aortic valve replacement (AVR), 656 mitral valve replacement (MVR) and 203 double valve replacement (DVR), additional procedures performed in 467 patients (282 coronary artery bypass grafting). Results: Early mortality was 97 (5%), overall survival at 8 years was 71.8% AVR, 69.4% MVR, 81.4% DVR. Total late valve-related deaths were 55; overall freedom from valve-related death at 8 years was 95%. New York Heart Association (NYHA) status after surgery: 78% improved and 17% unchanged. Twenty-two valve thrombosis were observed, one fatal; overall freedom from thrombosis at 8 years was 98.5%. Embolism occurred in 95 patients, 77 cerebral events (16 deaths), overall freedom from embolism was 90.7% at 8 years. Six hemolytic events and 26 non-structural dysfunction (all periprosthetic leaks) were reported. Major bleeding occurred in 66, with mortality rate of 32% mainly when intracerebral. Overall freedom from bleeding was 90.8% at 8 years. Endocarditis occurred in 31 patients, 29% were fatal; overall freedom from endocarditis was 97.8% at 8 years. Reoperation was performed in 49 cases – periprosthetic leak 20, infective endocarditis 14, thrombosed valve 13 (and non-valve related-2). Mortality (early and late) occurred in three reoperated patients. Conclusions: This is a durable and effective mechanical valve substitute with low morbidity and mortality and good functional results.

Key Words: Heart valve replacement • Bicarbon prosthesis • Bileaflet hinged mechanical device • Results




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
D. Baykut, L. Grize, C. Schindler, A. S. Keil, F. Bernet, and H.-R. Zerkowski
Eleven-year single-center experience with the ATS Open Pivot Bileaflet heart valve.
Ann. Thorac. Surg., September 1, 2006; 82(3): 847 - 852.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Josa, M. Castella, C. Pare, J. L. Bedini, R. Cartana, C. A. Mestres, J. L. Pomar, and J. Mulet
Hemolysis in Mechanical Bileaflet Prostheses: Experience With the Bicarbon Valve
Ann. Thorac. Surg., April 1, 2006; 81(4): 1291 - 1296.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Vitale, G. Cappabianca, G. Visicchio, C. Fondacone, V. Paradiso, G. Mannatrizio, and L. d. L. T. Schinosa
Midterm evaluation of the Sorin Bicarbon heart valve prosthesis: single-center experience
Ann. Thorac. Surg., February 1, 2004; 77(2): 527 - 531.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.