|
|
||||||||
Eur J Cardiothorac Surg 2003;24:113-118
© 2003 Elsevier Science NL
a Clinic for Cardiovascular Surgery, University Hospital, 8091 Zurich, Switzerland
b Division for Cardiology, University Hospital, Zurich, Switzerland
c Clinic for Anaesthesiology, University Hospital, Zurich, Switzerland
d Baylor College of Medicine, Houston, TX, USA
Received 9 January 2003; received in revised form 14 March 2003; accepted 17 March 2003.
* Corresponding author
e-mail: sacha.salzberg{at}chi.usz.ch
Objective: The MicroMed DeBakey left ventricular assist device (LVAD) axial blood flow pump was used as bridge to heart transplantation (HTx) in patients with terminal heart failure. The aim was to evaluate this novel mechanical circulatory support system in regard to overall outcome. Methods: Prospective study in 15 HTx candidates (mean age 40±7 years) with terminal heart failure and maximal medical treatment due to ischemic cardiomyopathy (CMP, n=5), dilated CMP (n=3), restrictive CMP (n=2), unclassified CMP (n=1), metabolic CMP (n=1), valvular CMP (n=1) and congenital CMP (n=2). All patients were implanted with a MicroMed DeBakey LVAD. A rescue procedure was necessary in eight critical patients, while seven underwent elective LVAD implantation. Procedures were performed via median sternotomy, in normotherm femoro-femoral CPB (mean duration 59±1 min). Oral Marcoumar© (INR 2.03.0) and Aspirin© (100 mg daily) were started as soon as possible. Patients were discharged into a specialized rehabilitation clinic from which it was possible to release them home after a few weeks. Results: Successful implantation and discharge from ICU (mean stay 10±7 days) was possible in 11 patients. Seven were transplanted (mean support 50.7 days) and one is awaiting HTx (support >310 days) in the comfort of his home (NYHA I). Survival was 100% among the transplanted patients. Of the seven elective implants, five, and of the eight rescue procedures three patients underwent successful HTx. Four patients died early, while three patients died late on pump support due to intracranial hemorrhage (n=2, 73 and 76 days) and chest infection (n=1, 124 days). All survivors were discharged from hospital, with significant decrease in NYHA class (mean 3.82.4 (n=11)). Treadmill testing showed increased exercise tolerance, from 35 to 71 W (n=4). Plasma BNP values (mean 950162 ng/l (n=4)) and pulmonary resistance (mean 316194.5 dyne s/cm5 (n=3)) decreased significantly during LVAD support. Conclusions: The MicroMed DeBakey LVAD is simple to implant; outpatient treatment is safe and efficient. Patients' condition and pulmonary resistances normalize within 6 weeks, making previously considered inoperable patients amenable for HTx. HTx can be performed in low-risk situation, allowing better donorrecipient matching and improving overall outcome.
Key Words: Terminal heart failure Axial blood flow Heart transplantation Left ventricular assist device Mechanical circulatory support
This article has been cited by other articles:
![]() |
O. Chikovani, J.-H. Hsu, R. Keller, T. R. Karl, A. Azakie, I. Adatia, P. Oishi, and J. R. Fineman B-type natriuretic peptide levels predict outcomes for children on extracorporeal life support after cardiac surgery. J. Thorac. Cardiovasc. Surg., November 1, 2007; 134(5): 1179 - 1187. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Lee, Y.-H. Park, S.-H. Lim, Y.-T. Kwak, H. Kim, and B.-C. Chang Successful Mechanical Circulatory Support as a Bridge to Transplantation Asian Cardiovasc Thorac Ann, June 1, 2007; 15(3): 243 - 245. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. H. Thoennissen, M. Schneider, A. Allroggen, M. Ritter, R. Dittrich, C. Schmid, H. H. Scheld, E. B. Ringelstein, and D. G. Nabavi High level of cerebral microembolization in patients supported with the DeBakey left ventricular assist device J. Thorac. Cardiovasc. Surg., October 1, 2005; 130(4): 1159 - 1166. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. P. Salzberg, M. L. Lachat, K. von Harbou, G. Zund, and M. I. Turina Normalization of high pulmonary vascular resistance with LVAD support in heart transplantation candidates Eur. J. Cardiothorac. Surg., February 1, 2005; 27(2): 222 - 225. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Loisance Mechanical circulatory support systems--future opportunities Eur. J. Cardiothorac. Surg., December 1, 2004; 26(Suppl_1): S48 - S53. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Hetzer, Y. Weng, E. V. Potapov, M. Pasic, T. Drews, M. Jurmann, E. Hennig, and J. Muller First experiences with a novel magnetically suspended axial flow left ventricular assist device Eur. J. Cardiothorac. Surg., June 1, 2004; 25(6): 964 - 970. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |