EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Kazutomo Minami
Dirk Seifert
Reiner Koerfer
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Koertke, H.
Right arrow Articles by Koerfer, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Koertke, H.
Right arrow Articles by Koerfer, R.
Related Collections
Right arrow Valve disease

Eur J Cardiothorac Surg 2003;24:52-58
© 2003 Elsevier Science NL


Does the noise of mechanical heart valve prostheses affect quality of life as measured by the SF-36® questionnaire?

Heinrich Koertke*, Annette Hoffmann-Koch, Dietmar Boethig, Kazutomo Minami, Thomas Breymann, Mahmoud El-Arousy, Dirk Seifert, Reiner Koerfer

Department of Thoracic and Cardiovascular Surgery, Heart Centre North-Rhine Westphalia Bad Oeynhausen, Clinic of the University of Bochum, Bochum, Germany

Received 27 January 2003; received in revised form 12 March 2003; accepted 17 March 2003.

* Corresponding author. HZ NRW, Georgstr. 11, D-32545 Bad Oeynhausen, Germany. Tel.: +49-5731-97-2319; fax: +49-5731-97-1871
e-mail: hkoertke{at}hdz-nrw.de

Objective: The closure clicks of mechanical heart valve prostheses' leaflets are quite often clearly audible. The study describes the effects of subjective valve sound perception on the patients' quality of life and analyses factors that might contribute to valve noise-related discomfort. Methods: We included 556 patients who received a mechanical valve prosthesis and participated in the study in our institution from 1994 to 1998. All compiled the standardised questionnaire Short-Form-36 Health Survey (SF-36®) and indicated their subjective disturbance grade pre- and postoperatively, then every 6 months up to 2 years. A series of factors was scanned for correlation with unpleasant noise perception. Results: Two years after the operation, only 5.8% classified their valve sounds as ‘quite’ or ‘very much’ disturbing. Age <60 years and being female were statistically significant factors for persisting unease caused by valve sounds. Without one of these factors, severe disturbance chance was 1.5%. As expected, quality of life improved after surgery. Patients disturbed seriously by valve noise showed significantly lower mean life quality values on each SF-36® scale. Conclusion: Patients (94.2%) with mechanical heart valve replacement have no persistent complaints about the valve noise. The grade of annoyance by valve noise is paralleled by lower average quality of life. Age under 60 years or being female increases the probability of severe disturbance due to mechanical valve sounds. It remains unclear whether the disturbing noise is reason or consequence of lower quality of life.

Key Words: Mechanical • Heart valve prosthesis • Questionnaire • Noise • Quality of life • SF-36®