Eur J Cardiothorac Surg 2003;24:86-91
© 2003 Elsevier Science NL
a Department of Thoracic and Cardiovascular Surgery, Yonsei Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, South Korea
b Department of Cardiology, Yonsei Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, South Korea
c Department of Radiology, Yonsei Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, South Korea
Received 12 September 2002; received in revised form 21 February 2003; accepted 17 March 2003.
* Corresponding author. Tel.: +82-2-361-7286; fax: +82-2-313-2992
e-mail: kjy{at}yumc.yonsei.ac.kr
Objective: Coronary angiography (CAG) is the gold standard method in evaluating graft patency following coronary artery bypass grafting (CABG), even though there are several kinds of non-invasive methods. Recently developed multi-slice CT (m-CT), having effective scan times up to 0.25 s and multi-row detector array systems, enable rapid imaging of cardiac structures, including coronary arteries during one breath-hold. We compared m-CT with CAG for the evaluation of graft patency following CABG. Methods: Forty-two patients having undergone m-CT and CAG within 3 months of CABG were studied. Twenty-three patients underwent conventional CABG and 19 off-pump CABG. A total of 125 grafts were used, including 42 left internal mammary arteries (LIMA), 25 radial arteries (RA), 3 right internal mammary arteries (RIMA) and 55 vein grafts. Results: CAG showed a 96% (120/125) patency rate (1 LIMA, 2 RA and 2 vein grafts were occluded). m-CT showed a 98% (122/125) correct positive ratio with a sensitivity and specificity of 98 and 100%, respectively. The sensitivity in LIMA, RA, RIMA and vein grafts was 98, 91, 100 and 100%, respectively, with 100% specificity for all. There was an equivocal result in the competitive grafts with native coronary artery that were patent in the CAG, but faint opacification with no significant flow in the m-CT. Conclusions: This study showed that m-CT was very simple, useful and accurate in evaluating graft patency during the early post-operative period following CABG, even though there was an equivocal result in the competitive grafts with a native coronary artery.
Key Words: Coronary artery bypass grafting Coronary angiography Multi-slice CT
This article has been cited by other articles:
![]() |
H. Doi, R. Koshima, M. Suzuki, K. Takahashi, H. Yokoyama, and N. Yoshida Can 64-Row Computed Tomography Replace Angiography After Coronary Bypass? Asian Cardiovasc Thorac Ann, December 1, 2008; 16(6): 444 - 449. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Malagutti, K. Nieman, W. B. Meijboom, C. A.G. van Mieghem, F. Pugliese, F. Cademartiri, N. R. Mollet, E. Boersma, P. P. de Jaegere, and P. J. de Feyter Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries Eur. Heart J., August 1, 2007; 28(15): 1879 - 1885. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, S. Attaran, A. Chow, S. Purkayastha, and A. Darzi Multi-slice computed tomography in coronary artery disease. Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 443 - 450. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Vernhet-Kovacsik, P. Battistella, R. Demaria, J. L. Pasquie, C. Bousquet, G. Dogas, F. Leclercq, B. Albat, and J. P. Senac Early Postoperative Assessment of Coronary Artery Bypass Graft Patency and Anatomy: Value of Contrast-Enhanced 16-MDCT with Retrospectively ECG-Gated Reconstructions Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S395 - S400. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Yamamoto, F. Kimura, H. Niinami, Y. Suda, E. Ueno, and Y. Takeuchi Noninvasive Assessment of Off-Pump Coronary Artery Bypass Surgery by 16-Channel Multidetector-Row Computed Tomography Ann. Thorac. Surg., March 1, 2006; 81(3): 820 - 827. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Poston, J. Gu, J. Manchio, A. Lee, J. Brown, J. Gammie, C. White, and B. P. Griffith Platelet function tests predict bleeding and thrombotic events after off-pump coronary bypass grafting Eur. J. Cardiothorac. Surg., April 1, 2005; 27(4): 584 - 591. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Martuscelli, A. Romagnoli, A. D'Eliseo, M. Tomassini, C. Razzini, M. Sperandio, G. Simonetti, F. Romeo, and J.L. Mehta Evaluation of Venous and Arterial Conduit Patency by 16-Slice Spiral Computed Tomography Circulation, November 16, 2004; 110(20): 3234 - 3238. [Abstract] [Full Text] [PDF] |
||||