Eur J Cardiothorac Surg 2004;25:160-166
© 2004 Elsevier Science NL
a Department of Cardiothoracic Surgery, University of Vienna, Währinger Gürtel 18-20, Vienna A-1090, Austria
b Thoracic Surgery Clinic, Korányi National Institute for Pulmonology, Budapest, Hungary
c Ruhrland Clinic, Essen, Germany
d Central Clinic, Augsburg, Germany
e University Hospital, Uppsala, Sweden
Received 8 August 2003; received in revised form 11 November 2003; accepted 16 November 2003.
* Corresponding author. Tel.: +43-1-40-400-5644; fax: +43-1-40-400-5642
e-mail: walter.klepetko{at}akh-wien.ac.at
Objective: Persisting air leakage after pulmonary resection remains a significant problem. The aim of the study was to evaluate the incidence of air leakage after standard lobectomy and test the efficacy and safety of TachoComb (TC). Methods: A total of 189 patients undergoing lobectomy were enrolled in a multi-centre, open, randomised, and prospective study to test the efficacy and safety of TachoComb (TC) for air leakage treatment. Air leakage was assessed by water submersion test, and scored as grades 0 if no, 1 if countable, 2 if a stream of and 3 if coalescent bubbles have been observed. Any sites with grade 3 air leakage received further stapling or limited suturing until grade 0, 1 or 2 was obtained. Treatment of air leakage was done with TC or suturing according to randomisation. Air leakage was assessed by further submersion tests. Postoperative air leakage was assessed using the Pleur-Evac system. Results: Overall incidence of air leakage 48±6 h after surgery was 34% for TC and 37% for standard treatment (P=0.76). The reduction of intra-operative air leak intensity in the subgroup with grades 12 was significantly higher for the TC group (P=0.015). Postoperative air leakage intensity in the subgroup with air leakage grades 12 was lower for TC than standard treatment (P=0.047). The mean duration of postoperative air leakage in the subgroup with grades 12 was shorter for the TC group than for standard treatment, i.e. 1.9±1.4 vs. 2.7±2.2 days (P=0.015). Conclusions: TC could be proven as well-tolerated and safe. In the subgroup of patients with established air leakage, TC showed superior potential in reduction of intra-operative air leakage as well as in reduction of intensity and duration of postoperative air leakage.
Key Words: Air leakage Lung tissue sealing TachoComb
This article has been cited by other articles:
![]() |
M. A. Erb, T. Claus, M. Hartrumpf, S. Bachmann, and J. M. Albes The use of Tachosil(R) surgical patch or fibrin glue in coronary artery surgery does not affect quality of anastomosis or provoke postoperative adhesions in pigs Eur. J. Cardiothorac. Surg., October 1, 2009; 36(4): 703 - 707. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Maisano, H. K. Kjaergard, R. Bauernschmitt, A. Pavie, G. Rabago, M. Laskar, J. P. Marstein, and V. Falk TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial Eur. J. Cardiothorac. Surg., October 1, 2009; 36(4): 708 - 714. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. D'Andrilli, C. Andreetti, M. Ibrahim, A. M. Ciccone, F. Venuta, U. Mansmann, and E. A. Rendina A prospective randomized study to assess the efficacy of a surgical sealant to treat air leaks in lung surgery Eur. J. Cardiothorac. Surg., May 1, 2009; 35(5): 817 - 821. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Droghetti, A. Schiavini, and G. Muriana Reply to the Editor: J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 507 - 508. [Full Text] [PDF] |
||||
![]() |
M. Kanzaki, M. Yamato, J. Yang, H. Sekine, R. Takagi, T. Isaka, T. Okano, and T. Onuki Functional closure of visceral pleural defects by autologous tissue engineered cell sheets Eur. J. Cardiothorac. Surg., October 1, 2008; 34(4): 864 - 869. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Moser, I. Opitz, W. Zhai, V. Rousson, E.W. Russi, W. Weder, and D. Lardinois Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study. J. Thorac. Cardiovasc. Surg., October 1, 2008; 136(4): 843 - 849. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Droghetti, A. Schiavini, P. Muriana, A. Folloni, M. Picarone, C. Bonadiman, C. Sturani, R. Paladini, and G. Muriana A prospective randomized trial comparing completion technique of fissures for lobectomy: stapler versus precision dissection and sealant. J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 383 - 391. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Anegg, R. Rychlik, and F. Smolle-Juttner Do the benefits of shorter hospital stay associated with the use of fleece-bound sealing outweigh the cost of the materials? Interactive CardioVascular and Thoracic Surgery, April 1, 2008; 7(2): 292 - 296. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Tambiah, R. Rawlins, D. Robb, and T. Treasure Can tissue adhesives and glues significantly reduce the incidence and length of postoperative air leaks in patients having lung resections? Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 529 - 533. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Anegg, J. Lindenmann, V. Matzi, J. Smolle, A. Maier, and F. Smolle-Juttner Efficiency of fleece-bound sealing (TachoSil(R)) of air leaks in lung surgery: a prospective randomised trial Eur. J. Cardiothorac. Surg., February 1, 2007; 31(2): 198 - 202. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Haas The Use of a Surgical Patch Coated With Human Coagulation Factors in Surgical Routine: A Multicenter Postauthorization Surveillance Clinical and Applied Thrombosis/Hemostasis, October 1, 2006; 12(4): 445 - 450. [Abstract] [PDF] |
||||
![]() |
P. Tansley, F. Al-Mulhim, E. Lim, G. Ladas, and P. Goldstraw A prospective, randomized, controlled trial of the effectiveness of BioGlue in treating alveolar air leaks J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 105 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Thomas, G. Massard, H. Porte, C. Doddoli, X. Ducrocq, and M. Conti A new bioabsorbable sleeve for lung staple-line reinforcement (FOREsealtrade mark): report of a three-center phase II clinical trial. Eur. J. Cardiothorac. Surg., June 1, 2006; 29(6): 880 - 885. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Getman, E. Devyatko, E. Wolner, S. Aharinejad, and M. R. Mueller Fleece bound sealing prevents pleural adhesions Interactive CardioVascular and Thoracic Surgery, June 1, 2006; 5(3): 243 - 246. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Belboul, L. Dernevik, O. Aljassim, B. Skrbic, G. Radberg, and D. Roberts The effect of autologous fibrin sealant (Vivostat(R)) on morbidity after pulmonary lobectomy: a prospective randomised, blinded study Eur. J. Cardiothorac. Surg., December 1, 2004; 26(6): 1187 - 1191. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |