EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dowling, R.D.
Right arrow Articles by Frazier, O.H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dowling, R.D.
Right arrow Articles by Frazier, O.H.
Related Collections
Right arrow Congestive Heart Failure
Right arrow Mechanical Circulatory Assistance
Right arrow Transplantation - heart

Eur J Cardiothorac Surg 2004;25:958-963
© 2004 Elsevier Science NL


HeartMate® VE LVAS design enhancements and its impact on device reliability

R.D. Dowlinga*, S.J. Parkb, F.D. Paganic, A.J. Tectord, Y. Nakae, T.B. Icenoglef, V.L. Poirierg,1, O.H. Frazierh

a University of Louisville, Louisville, KY, USA
b California Pacific Medical Center, San Francisco, CA, USA
c University of Michigan Health System, Ann Arbor, MI, USA
d St Lukes Medical Center, Milwaukee, WI, USA
e New York Presbyterian Hospital, New York, NY, USA
f Sacred Heart Medical Center, Spokane, WA, USA
g Thoratec Corporation, Pleasanton, CA, USA
h St Lukes Episcopal Hospital, Houston, TX, USA

Received 22 October 2003; received in revised form 4 March 2004; accepted 5 March 2004.

* Corresponding author. Address: Jewish Hospital Heart and Lung Institute, 217 East Chestnut Street, Louisville, KY 40202, USA. Tel.: +1-502-561-2180; fax: +1-502-584-2819
e-mail: rdowling{at}ucsamd.com

Objective: The HeartMate® VE left ventricular assist system (LVAS) has supported more than 2300 patients and has been shown to be effective for bridge to cardiac transplantation and has demonstrated improved outcomes in survival as a destination therapy. Improvements in device durability are needed as bridge to transplant times increase and as we move into the era of LVAD as destination therapy. The purpose of this study is to determine if design enhancements to the HeartMate LVAS have improved device reliability and durability. Methods: A retrospective analysis of serious mechanical failures was performed in 1865 devices (1458 VE, 407 XVE). The analysis of data included devices used to support patients from September 1998 for bridge to transplantation and destination therapy. Serious mechanical failures were defined as inflow valve dysfunction, percutaneous lead breaks, diaphragm fractures or punctures, bearing failures, outflow graft erosion and pump disconnects. Results: Median device duration for the VE was 97 days (max 1206 days), and 85 days (max 517 days) for the XVE. A total of 134 serious mechanical failures occurred and included inflow valve dysfunction (5.3% VE, 2.4% XVE) (P=0.853), percutaneous lead breaks (1.9% VE, 0% XVE) (P<0.001), diaphragm fractures (0.1% VE, 0% XVE) (P=0.134), outflow graft erosion (0.2% VE, 0% XVE) (P=0.1096), pump disconnects (0.1% VE, 0% XVE) (P=0.1336) and bearing failures (0.6% VE, 0.2% XVE) (P=0.5538). Of the XVEs 97% were free of serious mechanical failures at 6 months and 82% at 1 year compared to 92 and 73% for the VE, respectively. The 6-month difference between the devices was statistically significant (P=0.0063) and there was no statistically significant difference at 1 year (P=0.1492). Conclusions: Preliminary experience with the HeartMate XVE LVAS demonstrated a significant reduction in percutaneous lead breaks. Early trends indicate positive impact of recent design modifications on XVE performance. These design modifications may improve device durability and reliability, which is crucial as we enter the era of LVADs as an alternative to medical therapy.

Key Words: Left ventricular assist device • Assisted circulation




This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
D. Loisance
Mechanical Circulatory Support: a Clinical Reality
Asian Cardiovasc Thorac Ann, October 1, 2008; 16(5): 419 - 431.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. W. Long, A. H. Healy, B. Y. Rasmusson, C. G. Cowley, K. E. Nelson, A. G. Kfoury, S. E. Clayson, B. B. Reid, S. A. Moore, D. U. Blank, et al.
Improving outcomes with long-term "destination" therapy using left ventricular assist devices.
J. Thorac. Cardiovasc. Surg., June 1, 2008; 135(6): 1353 - 1361.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
I. D. Gregoric, B. A. Bruckner, L. Jacob, B. Kar, W. E. Cohn, S. La Francesca, and O.H. Frazier
Clinical Experience With Sternotomy Versus Subcostal Approach for Exchange of the HeartMate XVE to the HeartMate II Ventricular Assist Device.
Ann. Thorac. Surg., May 1, 2008; 85(5): 1646 - 1649.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
D. Esmore, P. Spratt, R. Larbalestier, S. Tsui, A. Fiane, P. Ruygrok, D. Meyers, and J. Woodard
VentrAssistTM left ventricular assist device: clinical trial results and Clinical Development Plan update
Eur. J. Cardiothorac. Surg., November 1, 2007; 32(5): 735 - 744.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. Chumnanvej, M. J. Wood, T. E. MacGillivray, and M. F. V. Melo
Perioperative Echocardiographic Examination for Ventricular Assist Device Implantation
Anesth. Analg., September 1, 2007; 105(3): 583 - 601.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Lietz, J. W. Long, A. G. Kfoury, M. S. Slaughter, M. A. Silver, C. A. Milano, J. G. Rogers, Y. Naka, D. Mancini, and L. W. Miller
Outcomes of Left Ventricular Assist Device Implantation as Destination Therapy in the Post-REMATCH Era: Implications for Patient Selection
Circulation, July 31, 2007; 116(5): 497 - 505.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. D. Pagani, J. W. Long, W. P. Dembitsky, L. D. Joyce, and L. W. Miller
Improved Mechanical Reliability of the HeartMate XVE Left Ventricular Assist System.
Ann. Thorac. Surg., October 1, 2006; 82(4): 1413 - 1418.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Schenk, S. Weber, W. A. Smith, and K. Fukamachi
MagScrew Total Artificial Heart
Ann. Thorac. Surg., June 1, 2006; 81(6): 2338 - 2339.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.