EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Ali Belboul
Leif Dernevik
Obaid Aljassim
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Belboul, A.
Right arrow Articles by Roberts, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Belboul, A.
Right arrow Articles by Roberts, D.
Related Collections
Right arrow Lung - other

Eur J Cardiothorac Surg 2004;26:1187-1191
© 2004 Elsevier Science NL


The effect of autologous fibrin sealant (Vivostat®) on morbidity after pulmonary lobectomy: a prospective randomised, blinded study

Ali Belboul*, Leif Dernevik, Obaid Aljassim, Biljana Skrbic, Göran Rådberg, Donald Roberts

Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Göteborg 413 45, Sweden

Received 5 June 2004; received in revised form 13 August 2004; accepted 15 August 2004.

* Corresponding author. Tel.: +46 31 3421556; fax: +46 31 417991. (E-mail: ali.belboul{at}hjl.gu.se).

Objective: Postoperative air leakage is the most frequent complication after pulmonary surgery. The development of modern surgical techniques has been influenced strongly by the need to manage air leakage effectively during pulmonary resection. This study evaluated the effect of using an autologous fibrin sealant (Vivostat®) during lobectomy on morbidity following surgery. Methods: This was a prospective, blinded, randomised clinical study. Patients undergoing lobectomy were enrolled into two groups (Vivostat or non-treatment control, 20 per group). Air leakage was measured over a 1-h period (using a mechanical suction pump) on the day of operation, and both air leakage and bleeding/exudation (drainage volume) were recorded every morning postoperatively until the chest tubes were removed. Personnel recording these parameters were blinded to the intervention received. Results: Compared with the control group, mean bleeding/exudate volumes were significantly reduced in the Vivostat group (day 1, 370 vs. 525ml; total, 424 vs. 782ml; both P<0.001), and drains were inserted for a shorter time (medians, 1 vs. 2 days, P=0.07). Significantly fewer patients had air leakage at any time in the Vivostat group (40 vs. 80%, P=0.02), and air leakage volumes were significantly lower compared with the control group (median differences: day of surgery: 0.6l/min, P=0.01; total 0.8l/min, P=0.03). Postoperative hospitalisation time was shorter in the Vivostat group than in the control group but the difference was not significant (0.5 days, P=0.12). Conclusions: Vivostat fibrin sealant significantly reduces post-surgical air leakage and drainage volumes following lobectomy in pulmonary surgery and is suitable for routine use in this procedure.




This article has been cited by other articles:


Home page
ICVTSHome page
G. Rocco, E. A. Rendina, F. Venuta, M. R. Mueller, S. Halezeroglu, H. Dienemann, D. V. Raemdonck, and H. J. Hansen
The use of sealants in modern thoracic surgery: a survey
Interactive CardioVascular and Thoracic Surgery, July 1, 2009; 9(1): 1 - 3.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. D'Andrilli, C. Andreetti, M. Ibrahim, A. M. Ciccone, F. Venuta, U. Mansmann, and E. A. Rendina
A prospective randomized study to assess the efficacy of a surgical sealant to treat air leaks in lung surgery
Eur. J. Cardiothorac. Surg., May 1, 2009; 35(5): 817 - 821.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. Moser, I. Opitz, W. Zhai, V. Rousson, E.W. Russi, W. Weder, and D. Lardinois
Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.
J. Thorac. Cardiovasc. Surg., October 1, 2008; 136(4): 843 - 849.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
P. Akhyari, H. Kamiya, A. Haverich, M. Karck, and A. Lichtenberg
Myocardial tissue engineering: the extracellular matrix.
Eur. J. Cardiothorac. Surg., August 1, 2008; 34(2): 229 - 241.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Araki, H. Tao, N. Nakajima, H. Sugai, T. Sato, S.-H. Hyon, T. Nagayasu, and T. Nakamura
Development of new biodegradable hydrogel glue for preventing alveolar air leakage.
J. Thorac. Cardiovasc. Surg., November 1, 2007; 134(5): 1241 - 1248.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
J. Tambiah, R. Rawlins, D. Robb, and T. Treasure
Can tissue adhesives and glues significantly reduce the incidence and length of postoperative air leaks in patients having lung resections?
Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 529 - 533.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Araki, H. Tao, T. Sato, N. Nakajima, H. Sugai, S.-H. Hyon, T. Nagayasu, and T. Nakamura
Creation of a uniform pleural defect model for the study of lung sealants
J. Thorac. Cardiovasc. Surg., July 1, 2007; 134(1): 145 - 151.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
L. Dernevik, A. Belboul, and G. Radberg
Initial experience with the world's first digital drainage system. The benefits of recording air leaks with graphic representation
Eur. J. Cardiothorac. Surg., February 1, 2007; 31(2): 209 - 213.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Tansley, F. Al-Mulhim, E. Lim, G. Ladas, and P. Goldstraw
A prospective, randomized, controlled trial of the effectiveness of BioGlue in treating alveolar air leaks
J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 105 - 112.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Intrapleural topical application of cisplatin with the surgical carrier Vivostat increases the local drug concentration in an immune-competent rat model with malignant pleuromesothelioma.
J. Thorac. Cardiovasc. Surg., March 1, 2006; 131(3): 697 - 703.e3.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.