|
|
||||||||
Eur J Cardiothorac Surg 2004;26:1187-1191
© 2004 Elsevier Science NL
Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Göteborg 413 45, Sweden
Received 5 June 2004; received in revised form 13 August 2004; accepted 15 August 2004.
* Corresponding author. Tel.: +46 31 3421556; fax: +46 31 417991. (E-mail: ali.belboul{at}hjl.gu.se).
Objective: Postoperative air leakage is the most frequent complication after pulmonary surgery. The development of modern surgical techniques has been influenced strongly by the need to manage air leakage effectively during pulmonary resection. This study evaluated the effect of using an autologous fibrin sealant (Vivostat®) during lobectomy on morbidity following surgery. Methods: This was a prospective, blinded, randomised clinical study. Patients undergoing lobectomy were enrolled into two groups (Vivostat or non-treatment control, 20 per group). Air leakage was measured over a 1-h period (using a mechanical suction pump) on the day of operation, and both air leakage and bleeding/exudation (drainage volume) were recorded every morning postoperatively until the chest tubes were removed. Personnel recording these parameters were blinded to the intervention received. Results: Compared with the control group, mean bleeding/exudate volumes were significantly reduced in the Vivostat group (day 1, 370 vs. 525ml; total, 424 vs. 782ml; both P<0.001), and drains were inserted for a shorter time (medians, 1 vs. 2 days, P=0.07). Significantly fewer patients had air leakage at any time in the Vivostat group (40 vs. 80%, P=0.02), and air leakage volumes were significantly lower compared with the control group (median differences: day of surgery: 0.6l/min, P=0.01; total 0.8l/min, P=0.03). Postoperative hospitalisation time was shorter in the Vivostat group than in the control group but the difference was not significant (0.5 days, P=0.12). Conclusions: Vivostat fibrin sealant significantly reduces post-surgical air leakage and drainage volumes following lobectomy in pulmonary surgery and is suitable for routine use in this procedure.
This article has been cited by other articles:
![]() |
G. Rocco, E. A. Rendina, F. Venuta, M. R. Mueller, S. Halezeroglu, H. Dienemann, D. V. Raemdonck, and H. J. Hansen The use of sealants in modern thoracic surgery: a survey Interactive CardioVascular and Thoracic Surgery, July 1, 2009; 9(1): 1 - 3. [Full Text] [PDF] |
||||
![]() |
A. D'Andrilli, C. Andreetti, M. Ibrahim, A. M. Ciccone, F. Venuta, U. Mansmann, and E. A. Rendina A prospective randomized study to assess the efficacy of a surgical sealant to treat air leaks in lung surgery Eur. J. Cardiothorac. Surg., May 1, 2009; 35(5): 817 - 821. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Moser, I. Opitz, W. Zhai, V. Rousson, E.W. Russi, W. Weder, and D. Lardinois Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study. J. Thorac. Cardiovasc. Surg., October 1, 2008; 136(4): 843 - 849. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Akhyari, H. Kamiya, A. Haverich, M. Karck, and A. Lichtenberg Myocardial tissue engineering: the extracellular matrix. Eur. J. Cardiothorac. Surg., August 1, 2008; 34(2): 229 - 241. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Araki, H. Tao, N. Nakajima, H. Sugai, T. Sato, S.-H. Hyon, T. Nagayasu, and T. Nakamura Development of new biodegradable hydrogel glue for preventing alveolar air leakage. J. Thorac. Cardiovasc. Surg., November 1, 2007; 134(5): 1241 - 1248. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Tambiah, R. Rawlins, D. Robb, and T. Treasure Can tissue adhesives and glues significantly reduce the incidence and length of postoperative air leaks in patients having lung resections? Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 529 - 533. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Araki, H. Tao, T. Sato, N. Nakajima, H. Sugai, S.-H. Hyon, T. Nagayasu, and T. Nakamura Creation of a uniform pleural defect model for the study of lung sealants J. Thorac. Cardiovasc. Surg., July 1, 2007; 134(1): 145 - 151. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Dernevik, A. Belboul, and G. Radberg Initial experience with the world's first digital drainage system. The benefits of recording air leaks with graphic representation Eur. J. Cardiothorac. Surg., February 1, 2007; 31(2): 209 - 213. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Tansley, F. Al-Mulhim, E. Lim, G. Ladas, and P. Goldstraw A prospective, randomized, controlled trial of the effectiveness of BioGlue in treating alveolar air leaks J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 105 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
Intrapleural topical application of cisplatin with the surgical carrier Vivostat increases the local drug concentration in an immune-competent rat model with malignant pleuromesothelioma. J. Thorac. Cardiovasc. Surg., March 1, 2006; 131(3): 697 - 703.e3. |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |