Eur J Cardiothorac Surg 2005;27:462-467
© 2005 Elsevier Science NL
Division of Image Processing, Departments of Radiology, Cardiology and Cardio-thoracic Surgery, Leiden University Medical Center, 2333ZA Leiden, The Netherlands
Received 31 August 2004; received in revised form 12 November 2004; accepted 22 November 2004.
* Corresponding author. Tel.: +31 71 526 4846; fax: +31 71 526 6801. (E-mail: j.j.m.westenberg{at}lumc.nl).
Objective: Echocardiography, the currently preferred diagnostic approach for mitral valve regurgitation, cannot accurately quantify the amount of regurgitation. Flow quantification with MRI is possible, but the conventional method (1-directional velocity-encoding) acquires the flow at a fixed location during the cardiac cycle, which is not necessarily the location of the mitral valve during the whole cycle. In this study, the exact flow through the mitral valve was quantified with a 3-directional velocity-encoded MRI approach. Methods: Ten patients with severe mitral valve regurgitation (class 34+with echocardiography) resulting from systolic restrictive motion of both leaflets (Carpentier IIIb) which were selected for valve repair and 10 healthy volunteers without cardiac valvular disease confirmed with echocardiography were included in this study. The intra-ventricular flow was sampled with a radial stack of six acquisition planes parallel to the long-axis of the left ventricle. Three-directional velocity-encoded MRI was performed resulting in the intra-ventricular flow velocity vector field for 30 phases during the cardiac cycle. The position of the mitral valvular plane in this vector field was indicated manually for each phase. Velocity values perpendicular to this plane determined the flow through the mitral valve. Both the 3-directional encoded mitral valve flow and the 1-directional encoded mitral valve flow were compared with the flow determined with MRI at the ascending aorta. Results: One-directional velocity-encoded MRI showed a mean overestimation (P<0.01) of 25ml/cycle compared to the aortic flow. Correlation was very poor (rP=0.15, P=0.68). The 3-directional velocity-encoded MRI on the other hand, showed no over/underestimation and a good correlation (rP=0.91, P<0.01 for volunteers, rP=0.90, P<0.01 for patients). The regurgitant flow fractions were between 3 and 30%. Conclusion: With 3-directional velocity-encoded MRI, measurement of the flow through the mitral valve is accurate and reproducible. This is a valuable tool for diagnosing and absolute quantification of regurgitant volume.
Key Words: Magnetic resonance imaging Mitral valve Regurgitation Flow quantification Image processing
This article has been cited by other articles:
![]() |
M. B. Srichai, R. P. Lim, S. Wong, and V. S. Lee Cardiovascular Applications of Phase-Contrast MRI Am. J. Roentgenol., March 1, 2009; 192(3): 662 - 675. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. M. Westenberg, S. D. Roes, N. Ajmone Marsan, N. M. J. Binnendijk, J. Doornbos, J. J. Bax, J. H. C. Reiber, A. de Roos, and R. J. van der Geest Mitral Valve and Tricuspid Valve Blood Flow: Accurate Quantification with 3D Velocity-encoded MR Imaging with Retrospective Valve Tracking Radiology, December 1, 2008; 249(3): 792 - 800. [Abstract] [Full Text] [PDF] |
||||
![]() |
Authors/Task Force Members, A. Vahanian, H. Baumgartner, J. Bax, E. Butchart, R. Dion, G. Filippatos, F. Flachskampf, R. Hall, B. Iung, et al. Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology Eur. Heart J., January 26, 2007; (2007) ehl428v1. [Full Text] [PDF] |
||||
![]() |
R. De Simone, I. Wolf, S. Mottl-Link, R. Hoda, B. Mikhail, F.-U. Sack, H.-P. Meinzer, and S. Hagl A clinical study of annular geometry and dynamics in patients with ischemic mitral regurgitation: new insights into asymmetrical ring annuloplasty Eur. J. Cardiothorac. Surg., March 1, 2006; 29(3): 355 - 361. [Abstract] [Full Text] [PDF] |
||||
![]() |
T A M Kaandorp, H J Lamb, E E van der Wall, A de Roos, and J J Bax Cardiovascular MR to access myocardial viability in chronic ischaemic LV dysfunction Heart, October 1, 2005; 91(10): 1359 - 1365. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |