EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Kazumasa Orihashi
Taijiro Sueda
Kenji Okada
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Orihashi, K.
Right arrow Articles by Imai, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Orihashi, K.
Right arrow Articles by Imai, K.
Related Collections
Right arrow Cerebral protection
Right arrow Extracorporeal circulation
Right arrow Great vessels

Eur J Cardiothorac Surg 2005;27:644-648
© 2005 Elsevier Science NL


Malposition of selective cerebral perfusion catheter is not a rare event

Kazumasa Orihashi*, Taijiro Sueda, Kenji Okada, Katsuhiko Imai

Division of Cardiovascular Surgery, Hiroshima University Hospital, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551, Japan

Received 1 October 2004; received in revised form 23 December 2004; accepted 27 December 2004.

* Corresponding author. Tel.: +81 82 257 5216; fax: +81 82 257 5219. (E-mail: orichan{at}hiroshima-u.ac.jp).

Objective: Although malposition of a catheter for selective cerebral perfusion can lead to postoperative neurologic complications, the clinical relevance or even an incidence of this event is not clear because there have been no measures to diagnose it. The purpose of this study is to report the results of intraoperative diagnosis of catheter malposition by means of near-infrared spectroscopy, orbital ultrasound, and transesophageal echocardiography. Methods: The 35 consecutive patients of aortic arch aneurysm undergoing total arch replacement (13 patients) or transaortic stent graft implantation (22 patients) were examined. The regional oxygen saturation in the frontal lobe was continuously monitored with near-infrared spectroscopy. When cerebral malperfusion was suspected with saturation drop and reduced blood flow in orbital ultrasound, blood flow in the cervical branches and catheter position were examined with transesophageal echocardiography. Results: Catheter malposition was detected in 4 of 35 cases (11.4%). The echo findings included: (1) reduced or absent flow and/or collapsed lumen in the common carotid artery despite an adequate perfusion rate; and (2) the balloon of catheter blocking the inflow to the common carotid artery. There was no unusual changes in parameters of other conventional monitors. After the catheter was withdrawn (three cases) or replaced (one case) based on the above diagnosis, cerebral perfusion was restored, confirmed by these three modalities. An accidental entry of catheter into the right common carotid artery was detected by transesophageal echocardiography in one case, in which there was no abnormal finding of oxygen saturation or orbital blood flow. Conclusions: Catheter malposition on the right side is not a rare event during selective cerebral perfusion. The catheter can migrate into the right subclavian artery or common carotid artery. Pressure monitoring cannot reliably detect an occurrence of catheter migration into the right subclavian artery. Combined use of near-infrared spectroscopy, orbital ultrasound, and transesophageal echocardiography can be useful for detecting this event and making an appropriate decision without delay to prevent irreversible brain damage.

Key Words: Selective cerebral malperfusion • Aortic arch aneurysm • Transesophageal echocardiography • Malperfusion • Near-infrared spectroscopy




This article has been cited by other articles:


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
G. W. Fischer
Recent Advances in Application of Cerebral Oximetry in Adult Cardiovascular Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2008; 12(1): 60 - 69.
[Abstract] [PDF]


Home page
Card Surg AdultHome page
D. Spielvogel, M. N. Mathur, and R. B. Griepp
Aneurysms of the Aortic Arch
Card. Surg. Adult, January 1, 2008; 3(2008): 1251 - 1276.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
H. Gulbins, A. Pritisanac, and J. Ennker
Axillary Versus Femoral Cannulation for Aortic Surgery: Enough Evidence for a General Recommendation?
Ann. Thorac. Surg., March 1, 2007; 83(3): 1219 - 1224.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Spielvogel, C. D. Etz, D. Silovitz, S. L. Lansman, and R. B. Griepp
Aortic Arch Replacement With a Trifurcated Graft
Ann. Thorac. Surg., February 1, 2007; 83(2): S791 - S795.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.