EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Akihiko Usui
Yuichi Ueda
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sasaki, M.
Right arrow Articles by Ueda, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sasaki, M.
Right arrow Articles by Ueda, Y.
Related Collections
Right arrow Cerebral protection
Right arrow Extracorporeal circulation
Right arrow Great vessels

Eur J Cardiothorac Surg 2005;27:821-825
© 2005 Elsevier Science NL


Arch-first technique performed under hypothermic circulatory arrest with retrograde cerebral perfusion improves neurological outcomes for total arch replacement

Michio Sasaki, Akihiko Usui*, Masaharu Yoshikawa, Toshiaki Akita, Yuichi Ueda

Department of Cardio-Thoracic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa-ku, Nagoya 466-8550, Japan

Received 2 November 2004; received in revised form 24 January 2005; accepted 25 January 2005.

* Corresponding author. Tel.: +81 52 744 2376; fax: +81 52 744 2383. (E-mail: ausui{at}med.nagoya-u.ac.jp).

Objective: From 1998, we have adopted the arch first technique (reconstruction of arch vessels first and distal anastomosis second) instead of the distal anastomosis first technique for total arch replacement. The aim is to reduce the period of deep hypothermic circulatory arrest and the retrograde cerebral perfusion time. We evaluate the surgical results of the arch first technique. Methods: The arch first technique was used in 50 cases (38 male and 12 female), of average age 68 years, from 1998 to 2003. There were 33 true aneurysms and 10 chronic and seven acute type A dissections. Clinical results were evaluated and compared with the distal first technique used in 24 cases operated on between 1992 and 1998. These were 14 males and 10 females, with an average age of 68 years. There were 16 true aneurysms, and three chronic and five acute aortic dissections. Results: For the arch first technique there is a significantly shorter circulatory arrest time (32 vs. 72min, P<0.0001), but similar body ischemic times (76 vs. 72min, N.S.). With the arch first technique, all but two patients awoke within 24h, with an average delay of 9.3h. In the distal first technique, two patients did not awaken and three patients showed delayed awakening, with an average awakening time of 24h. The arch first technique led to one hospital death (2%), due to residual aneurysm rupture. Reversible ischemic neurological deficit (RIND) was complicated in three cases (6%), but no stroke occurred during operation. In the distal first technique there were four strokes, one RIND and three hospital deaths (12.5%). The arch first technique gave a significantly lower intra-operative stroke rate (P=0.0030) and smaller hospital mortality (P=0.0615). The arch first technique led to five late deaths, with an 84.5% 3 year survival rate, and the distal first technique led to six late deaths with a 59.1% 3-year survival rate. Conclusions: The arch first technique is clearly superior to the conventional distal first technique in surgical mortality and morbidity regarding neurological outcome, and provides a higher survival rate and better quality of life. The arch first technique is an excellent method for total arch replacement.

Key Words: Aortic arch • Survival analysis • Retrograde perfusion • Quality of life • Cerebral protection




This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
M.-H. Song, Y. Tokuda, M. Hirai, and Y. Ueda
Learning Curve of Arch-First Technique Analyzed by Cumulative Sum
Asian Cardiovasc Thorac Ann, December 1, 2007; 15(6): 507 - 510.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.