EJCTS Click here to go to Edwards website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Corno, A. F.
Right arrow Articles by von Segesser, L. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Corno, A. F.
Right arrow Articles by von Segesser, L. K.
Related Collections
Right arrow Congenital - acyanotic
Right arrow Congenital - cyanotic
Right arrow Great vessels

Eur J Cardiothorac Surg 2006;29:93-99
© 2006 Elsevier Science NL

The non-circular shape of FloWatch®-PAB prevents the need for pulmonary artery reconstruction after banding.

Computational fluid dynamics and clinical correlations

Antonio F. Corno a , * , Martin Prosi b , Pierre Fridez c , Paolo Zunino b , Alfio Quarteroni c , Ludwig K. von Segesser d

a Alder Hey Royal Children Hospital, Eaton Road, Liverpool, L12 2AP, England, UK
b MOX, Politecnico di Milano, Milano, Italy
c Ecole Polytéchnique Fédérale Lausanne, Lausanne, Switzerland
d Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland

Received 19 June 2005; received in revised form 16 September 2005; accepted 17 October 2005.

* Corresponding author. Tel.: +44 151 2525713; fax: +44 151 2525643. (Email: Antonio.Corno{at}rlc.nhs.uk).

Objective: To evaluate the differences between non-circular shape of FloWatch®-PAB and conventional pulmonary artery (PA) banding. Methods: Geometrical analysis. Conventional banding and FloWatch®-PAB perimeters were plotted against cross-sections. Computational fluid dynamics (CFD) model. CFD compared non-circular FloWatch®-PAB cross-sections with conventional banding regarding pressure gradients. Clinical data. Seven children, median age 2 months (7 days to 3 years), median weight 4.2 kg (3.2–9.8 kg), with complex congenital heart defects underwent PA banding with FloWatch®-PAB implantation. Results: Geometrical analysis. Conventional banding: progressive reduction of cross-sections was accompanied by progressive reduction of PA perimeters. FloWatch®-PAB: with equal reduction of cross-sections the PA perimeter remained constant. CFD model. Non-circular and circular banding provided same trans-banding pressure gradients for same cross-sections at any given flow. Clinical data. Mean PA internal diameter at banding was 13.3 ± 4.5 mm. After a mean interval of 5.9 ± 3.7 months, all children underwent intra-cardiac repair and simple FloWatch®-PAB removal without PA reconstruction. Mean PA internal diameter with FloWatch®-PAB removal increased from 3.0 ± 0.8 to 12.4 ± 4.5 mm (normal mean internal diameter for the age = 9.9 ± 1.6). No residual pressure gradient was recorded in correspondence of the site of the previous FloWatch®-PAB implantation in 6/7 patients, 10 mmHg peak and 5 mmHg mean gradient in 1/7. Conclusions: The non-circular shape of FloWatch®-PAB can replace conventional circular banding with the following advantages: (a) the pressure gradient will remain essentially the same as for conventional circular banding for any given cross-section, but with significantly smaller reduction of PA perimeter; and (b) PA reconstruction at the time of de-banding for intra-cardiac repair can be avoided.

Key Words: Congenital heart disease • Pulmonary arteries • Pulmonary artery banding • Pulmonary hypertension • Surgery • Ventricular septal defect




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
A. F. Corno
Invited Commentary
Ann. Thorac. Surg., February 1, 2008; 85(2): 598 - 598.
[Full Text] [PDF]


Home page
ICVTSHome page
A. F. Corno and E. S. Mickaily-Huber
Comparative computational fluid dynamic study of two distal Contegra conduit anastomoses
Interactive CardioVascular and Thoracic Surgery, February 1, 2008; 7(1): 1 - 5.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. S. Assad, M. M. Zamith, M. F. Silva, P. G. Thomaz, L. A. Miana, V. C. Guerra, C. A. Pedra, and M. B. Marcial
A Novel Adjustable Pulmonary Artery Banding System for Hypoplastic Left Heart Syndrome
Ann. Thorac. Surg., December 1, 2007; 84(6): 2081 - 2084.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. F. Corno, E. J. Ladusans, M. Pozzi, and S. Kerr
FloWatch versus conventional pulmonary artery banding.
J. Thorac. Cardiovasc. Surg., December 1, 2007; 134(6): 1413 - 1420.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. F. Corno, M. Pozzi, and L. K. von Segesser
FloWatch and pseudoaneurysm: Complication versus coincidence
J. Thorac. Cardiovasc. Surg., April 1, 2006; 131(4): 928 - 929.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2006 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.