Eur J Cardiothorac Surg 2006;29:253-254
© 2006 Elsevier Science NL
How-to-do-it |
Pediatric Cardiac Surgery Unit, S.Orsola-Malpighi Hospital, Bologna Medical School, Via Massarenti 9, 40138 Bologna, Italy
Received 26 August 2005; received in revised form 7 November 2005; accepted 15 November 2005.
* Corresponding author. Tel.: +39 051 6363156; fax: +39 051 6363157. (Email: pax{at}med.unibo.it).
The BlalockTaussig shunt can produce a temporary pulmonary over-circulation and can be downsized with a metallic clip. This hemodynamic situation can be reversible leading to desaturation.
We describe a very simple method to resize temporarily the shunt with a removable metallic clip.
Key Words: Hypoplastic left heart syndrome Shunt anastomosis Surgical Pulmonary circulation