Eur J Cardiothorac Surg 2006;29:1001-1006
© 2006 Elsevier Science NL
a Department for Congenital Cardiac Surgery, University Children's Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
b Department of Anesthesia, University Children's Hospital Zurich, Zurich, Switzerland
Received 27 September 2005; received in revised form 18 January 2006; accepted 26 January 2006.
* Corresponding author. Tel.: +41 1 266 8020; fax: +41 1 266 8021. (Email: rene.pretre{at}kispi.unizh.ch).
Objective: To evaluate the early results of a new method to repair malfunctioning bicuspid aortic valves by creating a tricuspid valve with a crown-like (i.e. anatomic) annulus. Material and methods: Twelve patients (ages from 10 to 27 years) with chronic regurgitation (and flow-dependent stenosis) of a bicuspid aortic valve underwent repair with the principle of creating a tricuspid valve and a crown-like annulus. The fused leaflets were trimmed and reinserted underneath the existing aortic annulus to create one new native cusp. The third leaflet was fashioned out of a xenopericard patch and was inserted underneath the existing annulus as well to restore the crown-like anatomy of a normal aortic annulus. A tricuspid aortic valve with a morphologically normal annulus was thus created, which resulted in improved coaptation of the leaflets. The repair was immediately assessed by transesophageal echocardiography (TEE) with the heart loaded at 50%. In two patients, a second run helped fine-tune the repair. Median cross-clamping time was 82 min. Follow-up ranged from 3 to 46 months (median 13 months). Results: No significant complication occurred. The function of the aortic valve was excellent with trivial or mild regurgitation in 11 patients and moderate regurgitation in 1 patient. There was no stenosis across the valve. The repair remained stable over time. Remodelling of the left ventricle occurred as expected. Conclusions: Aortic valve repair is feasible in some dysfunctioning bicuspid aortic valves. Tricuspidisation of the valve can result in excellent systolic and diastolic functions. The creation of a crown-like annulus results in improved coaptation of the cusps and could lead to more reliable outcome. Although long-term results are needed, this anatomic correction seems to be a good alternative to valvular replacement in certain sub-groups of patients.
Key Words: Reconstruction Bicuspid Aortic valve Valve repair
This article has been cited by other articles:
![]() |
H.-J. Schafers, D. Aicher, S. Riodionycheva, A. Lindinger, T. Radle-Hurst, F. Langer, and H. Abdul-Khaliq Bicuspidization of the Unicuspid Aortic Valve: A New Reconstructive Approach Ann. Thorac. Surg., June 1, 2008; 85(6): 2012 - 2018. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Aicher, F. Langer, O. Adam, D. Tscholl, H. Lausberg, and H.-J. Schafers Cusp repair in aortic valve reconstruction: Does the technique affect stability? J. Thorac. Cardiovasc. Surg., December 1, 2007; 134(6): 1533 - 1539. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Dave and R. Pretre Pericardial patch reconstruction of the congenitally diseased aortic valve MMCTS, May 7, 2007; 2007(0507): 1354. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. H. Anderson The surgical anatomy of the aortic root MMCTS, February 19, 2007; 2007(0219): 2527. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. H. Anderson Editorial comment: Demystifying the anatomic arrangement of the aortic valve Eur. J. Cardiothorac. Surg., June 1, 2006; 29(6): 1006 - 1007. [Full Text] [PDF] |
||||