|
|
||||||||
Eur J Cardiothorac Surg 2006;29:880-885
© 2006 Elsevier Science NL
a Department of Thoracic Surgery, University Hospital of Marseille, France
b Department of Thoracic Surgery, University Hospital of Strasbourg, France
c Department of Thoracic Surgery, University Hospital of Lille, France
Received 4 December 2005; received in revised form 24 January 2006; accepted 26 January 2006.
* Corresponding author. Address: Department of Thoracic Surgery, Ste Marguerite Hospital-CHU Sud, 270 Bd Ste Marguerite, 13274 Marseille Cedex 9, France. Tel.: +33 491 744 680; fax: +33 491 744 590. (Email: Pascal-alexandre.Thomas{at}mail.ap-hm.fr).
Objective: To investigate on the feasibility, safety, and effectiveness of a new bioabsorbable material for lung staple-line reinforcement. Methods: This prospective open trial included 66 patients (mean age of 56 ± 17 years) who underwent various types of lung resection using staplers with knitted calcium alginate sleeves for buttressing (FOREsealTM, Laboratoires Brothier, Nanterre, France) at three academic centers: 29 lobectomies, 22 emphysema surgeries, 15 wedge resections or lung biopsies. Intraoperative air leakage was assessed at a mean respiratory peak pressure of 30 cmH2O, and rated as grade 1, 2, or 3. Persistent air leakage in the postoperative course, as well as any relevant event, was assessed daily. The follow-up period was of 6 months. Results: No technical problem linked to the device occurred. Hemostasis of the cutting edges was completed in all patients. Fifty-six percent of the patients had no intraoperative air leak and 27.3% had grade 1 leaks. Mean postoperative air leaks and thoracic drainage times were 1.9 ± 2.3 days and 6 ± 5.3 days, respectively. In-hospital mortality was nil. There was no empyema. Mean hospital stay was 9.1 ± 6.6 days. At follow-up, one patient underwent lung transplantation, and pathology of the explanted specimen showed the absence of device-related foreign-body inflammation. One patient complained from metalloptysis, and another one, with a metastatic invasive aspergillosis, developed an infectious recurrence that required reoperation. Conclusions: FOREseal is an ergonomic, safe, and promising new material instead of nonabsorbable materials and xenomaterials for staple-line reinforcement. A randomized comparative study is now in progress.
Key Words: Lung surgery New technology
This article has been cited by other articles:
![]() |
O. Rena, E. Papalia, T. C. Mineo, F. Massera, E. Pirondini, D. Turello, and C. Casadio Air-leak management after upper lobectomy in patients with fused fissure and chronic obstructive pulmonary disease: a pilot trial comparing sealant and standard treatment Interactive CardioVascular and Thoracic Surgery, December 1, 2009; 9(6): 973 - 977. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Droghetti, A. Schiavini, P. Muriana, A. Folloni, M. Picarone, C. Bonadiman, C. Sturani, R. Paladini, and G. Muriana A prospective randomized trial comparing completion technique of fissures for lobectomy: stapler versus precision dissection and sealant. J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 383 - 391. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |