EJCTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Eur J Cardiothorac Surg 2008;33:164-167. doi:10.1016/j.ejcts.2007.11.021
Copyright © 2008, European Association for Cardio-thoracic Surgery. Published by Elsevier. All rights reserved.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Yoshiyuki Tokuda
Min-Ho Song
Yuichi Ueda
Akihiko Usui
Toshiaki Akita
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Tokuda, Y.
Right arrow Articles by Maruyama, S.
PubMed
Right arrow Articles by Tokuda, Y.
Right arrow Articles by Maruyama, S.
Related Collections
Right arrow Extracorporeal circulation

Three-dimensional numerical simulation of blood flow in the aortic arch during cardiopulmonary bypass

Yoshiyuki Tokudaa,*, Min-Ho Songa, Yuichi Uedab, Akihiko Usuib, Toshiaki Akitab, Shigeru Yoneyamac, Shigeru Maruyamad

a Department of Cardiovascular Surgery, Gifu Prefectural Tajimi Hospital, 5-161 Maehata, Tajimi, Gifu 507-8522, Japan
b Department of Cardiothoracic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa-ku, Nagoya, Aichi 466-8550, Japan
c Maxnet Co. Ltd., 5-52-15 Nakano, Nakano-ku, Tokyo 165-0001, Japan
d Numcraft Inc., 76-1735 Horiuchi, Hyama, Miura, Kanagawa 240-0112, Japan

Received 31 March 2007; received in revised form 13 August 2007; accepted 26 November 2007.

* Corresponding author. Tel.: +81 572 22 5311; fax: +81 572 25 1246. (Email: tokuda{at}mxb.mesh.ne.jp).

Objective: To better understand the mechanism of stroke during cardiopulmonary bypass, it is necessary to obtain information on the location of turbulence, wall pressure, and flow distribution within the aortic arch. Methods: Blood flow was numerically simulated using the finite element method in the following representative case: a curved arterial cannula was inserted into the anterior wall of the distal ascending aorta 2 cm below the orifice of brachiocephalic artery. Perfusion was performed, with a bypass flow index of 2.5 l min–1 m–2. Computational grids, consisting of 1,493,297 tetrahedral elements, were generated. Results: The highest wall pressure (3104.8 Pa) was observed at the superior-posterior wall of the aorta below the orifice of the brachiocephalic artery where jet flow impingement occurred. The maximum wall shear stress was 25.1 Pa. High velocity vortex started below the orifice of the brachiocephalic artery. The turbulent flows continued along the posterior wall and then mainly flowed off into the left subclavian artery. Therefore, in the present case, an embolic event in the territory of the left subclavian artery could occur if a plaque was present at the superior-posterior wall of the aorta below the orifice of the brachiocephalic artery. The flow rates in each of the branches were 132, 613, 175, and 821 ml/min for the right subclavian, right common carotid, left common carotid, and left subclavian artery, respectively. Conclusion: This study confirmed that blood flow during cardiopulmonary bypass can be simulated and visualized. Computational fluid dynamics could be applied in the future to assess an individual's risk of stroke. Further multiple representative cases need to be simulated.

Key Words: Cardiopulmonary bypass • Computer simulation