EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Eur J Cardiothorac Surg 2008;34:11-16. doi:10.1016/j.ejcts.2008.03.047
Copyright © 2008, European Association for Cardio-thoracic Surgery. Published by Elsevier. All rights reserved.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow On-line Video
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Ernst Weigang
Friedhelm Beyersdorf
Maximilian Luehr
Christian D. Etz
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weigang, E.
Right arrow Articles by Markl, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Weigang, E.
Right arrow Articles by Markl, M.
Related Collections
Right arrow Great vessels

Flow-sensitive four-dimensional magnetic resonance imaging: flow patterns in ascending aortic aneurysms

Ernst Weiganga,1,*, Fabian A. Karib,1, Friedhelm Beyersdorfc, Maximilian Luehrc, Christian D. Etzb, Alex Frydrychowiczd, Andreas Harloffe, Michael Marklf

a Department of Cardiothoracic and Vascular Surgery, University Hospital Mainz, Langenbeckstraße 1, D-55131 Mainz, Germany
b Department of Cardiothoracic Surgery, Mount Sinai Medical School, New York, NY, USA
c University Cardiovascular Center Freiburg, Bad Krozingen, Freiburg, Germany
d Diagnostic Radiology, University Medical Center Freiburg, Freiburg, Germany
e Neurology and Neurophysiology, University Medical Center Freiburg, Freiburg, Germany
f Department of Diagnostic Radiology, Medical Physics, University Medical Center Freiburg, Freiburg, Germany

Received 23 October 2007; received in revised form 18 March 2008; accepted 19 March 2008.

* Corresponding author. Tel.: +49 172 9328330. (Email: ernst.weigang{at}web.de).

Objective: Pathological aortic flow patterns differ significantly from haemodynamics within the healthy aorta. Development and impact of pathological flow is largely unknown and might affect pathogenesis and the progression of thoracic aortic diseases. This study presents pathological blood-flow patterns within a series of six patients suffering from ascending aortic aneurysms investigated with high-detail flow-sensitive, four-dimensional (4D)-MRI and three-dimensional (3D) computer-aided flow-visualisation strategies. Methods: Data were acquired on a 3 T magnetic resonance system (TRIO, Siemens, Erlangen, Germany) using a flow-sensitive 4D (time-resolved 3D) sequence protocol. Measurements were taken in synchrony with the cardiac cycle and under respiration control. After data pre-processing, blood-flow was visualised by means of systolic 3D streamlines and time-resolved 3D particle traces using the software EnSight (CEI, Apex, NC, USA) and homemade visualisation tools. We investigated six adult patients with ascending aortic aneurysms and one healthy individual and findings were compared to 3D-haemodynamics of the dilated ascending aorta described in current literature. Results: Normal blood-flow in the healthy volunteer resulted in highest velocities of up to 1 ms in the ascending and descending aorta, a right-handed helical flow pattern featuring 0.5–1.5 revolutions within the ascending aorta was present. Two atherosclerotic aneurysms presented either increased right-handed helical flow with flow acceleration along the great curvature, or multiple vortical flows in the sinuses and middle of the ascending aorta. One Marfan-associated aneurysm exhibited increased vortical flow in the dilated sinuses. One pseudo-aneurysm at the proximal anastomosis of an earlier supracoronary aortic replacement showed extensive vortex formation inside the aneurysm's lumen. An aneurysm in a patient with a bicuspid aortic valve revealed one major vortex formation directly above the aortic valve. One aneurysm following congenital valvular stenosis and commissurotomy in childhood was characterised by helical diastolic backflow in the central ascending aorta and a vortex at the small curvature. Conclusion: Patients with ascending aortic aneurysms reveal considerable differences in local flow patterns among themselves and compared to healthy individuals. Further investigations are necessary to identify flow patterns predisposing to aortic aneurysm development or adverse events in the course of aortic disease.

Key Words: Aorta/aortic • Aortic root • Aneurysm • Imaging (all modalities) • Magnetic resonance imaging (MRI)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.