European Journal of Cardio-Thoracic Surgery, Vol 4, 345-345, Copyright © 1990 by European Association for Cardio-thoracic Surgery
SM van Sterkenburg, A Brutel de la Riviere and FE Vermeulen
The applicability of absorbable sutures for sternal closure was
investigated. Heavy braided Polydioxanon (PDS Ethicon) sutures were tested
in a routine fashion, as were steel wire and braided polyester. In a pilot
study, 2 patients (20%) had a complete sternal dehiscence. These results
forced us to abandon the project.
ARTICLES
Sternal fixation with resorbable suture material
Department of Cardiothoracic Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands.
This article has been cited by other articles:
![]() |
N. Luciani, A. Anselmi, and G. Possati Adjusting the indication to polydioxane suture for elective sternal closure. J. Thorac. Cardiovasc. Surg., November 1, 2006; 132(5): 1243 - 1244. [Full Text] [PDF] |
||||
![]() |
A. Al-Qudah Operative Treatment of Sternal Fractures Asian Cardiovasc Thorac Ann, October 1, 2006; 14(5): 399 - 401. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Pastorino, G. Muscolino, M. Valente, S. Andreani, L. Tavecchio, M. Infante, G. Terno, and G. Ravasi Safety of absorbable suture for sternal closure after pulmonary or mediastinal resection J. Thorac. Cardiovasc. Surg., February 1, 1994; 107(2): 596 - 599. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |