|
|
||||||||
European Journal of Cardio-Thoracic Surgery, Vol 6, 246-249, Copyright © 1992 by European Association for Cardio-thoracic Surgery
LK von Segesser, BM Weiss, E Garcia and M Turina
Two series of 20 consecutive patients with aneurysms of the descending
thoracic aorta (TAA) and thoraco-abdominal aorta (TAAA) underwent
multisegmental aortic repair using either simple normothermic crossclamping
and rapid reanastomosis (historic) or partial cardiopulmonary bypass (CPB)
with heparin coated perfusion equipment and low systemic heparinization
(actual). Chronic lesions were present in 14/20 patients (70%) for simple
versus 13/20 (65%) for CPB (NS). Acute lesions (symptomatic less than 24 h)
were present in 6/20 patients (30%) for simple versus 7/20 (35%) for CPB
(NS). Dissecting lesions were observed in 4/20 patients (20%) for simple
versus 8/20 (40%) for CPB (NS). Aneurysmal lesions were found in 16/20
patients (80%) for simple versus 12/20 (60%) for CPB (NS). Mean number of
aortic segments (n = 8) resected was 3.2 +/- 1.1 for simple versus 4.0 +/-
1.2 for CPB (P less than 0.01). Replacement of the transdiaphragmatic aorta
was performed in 10/20 patients (50%) for simple and 13/20 patients (65%)
for CPB (NS). A heparin loading dose of 5000 IU for simple versus 100 IU/kg
bodyweight for CPB was used. In the latter group, the activated clotting
time was kept above 180 s during a mean perfusion time of 46 +/- 28 min at
a mean pump flow of 2.2 +/- 0.7 l/min. Thirty- day survival for all
(transdiaphragmatic) was 12/20 (5/10) patients for simple versus 20/20
(13/13) for CPB (P less than 0.002, P less than 0.01). One-year survival
(all) was 11/20 patients (55%) for simple versus 19/20 (95%) for CPB (P
less than 0.005).(ABSTRACT TRUNCATED AT 250 WORDS)
ARTICLES
Perfusion with low systemic heparinization during resection of descending thoracic aortic aneurysms
Clinic for Cardiovascular Surgery, University Hospital, Zurich, Switzerland.
This article has been cited by other articles:
![]() |
L. K. von Segesser Perfusion techniques during surgery of the thoracic and thoraco-abdominal aorta: the veno-arterial bypass MMCTS, June 19, 2007; 2007(0619): 2535. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. von Segesser, T. Tkebuchava, B. Leskosek, P. Pei, B. von Felten, and M. Turina Low prime, heparin coated centrifugal pumps Perfusion, May 1, 1995; 10(3): 177 - 182. [PDF] |
||||
![]() |
L. K von Segesser Use of heparin-bonded surfaces in cardiopulmonary bypass Perfusion, May 1, 1993; 8(1_suppl): 21 - 27. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |