EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Honek, T.
Right arrow Articles by Stark, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Honek, T.
Right arrow Articles by Stark, J.

European Journal of Cardio-Thoracic Surgery, Vol 6, 308-310, Copyright © 1992 by European Association for Cardio-thoracic Surgery


ARTICLES

Minimisation of priming volume and blood saving in paediatric cardiac surgery

T Honek, P Horvath, V Kucera, M Kostelka, B Hucin and J Stark
Kardiocentrum, Prague, Czechoslovakia.

We started a programme of donor blood reduction for open heart surgery in children in 1983. At first, only meticulous surgical and perfusion techniques were used. Later, increased haemodilution was added. Miniaturisation of the perfusion circuit and introduction of blood taken prior from the patient further decreased donor blood requirements. In 1989, we used 0.89 l per patient compared to 3.2 l per patient in 1983. Miniaturisation of the circuit was tested in a pilot study on 30 children undergoing the Senning operation in 1988. Priming volume was reduced from 661 +/- 72 ml to 421 +/- 62 ml. In 1989, 167 out of 194 children (86%) received a clear prime. Ninety-seven of 100 children whose weight was over 15 kg received a clear prime: 55 did not require subsequent transfusion. Prime miniaturisation and autotransfusion can considerably reduce blood requirements for open heart surgery.


This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
K. Nakanishi, T. Shichijo, Y. Shinkawa, S. Takeuchi, M. Nakai, G. Kato, and O. Oba
Usefulness of vacuum-assisted cardiopulmonary bypass circuit for pediatric open-heart surgery in reducing homologous blood transfusion
Eur. J. Cardiothorac. Surg., August 1, 2001; 20(2): 233 - 238.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. Petaja, U. Lundstrom, M. Leijala, K. Peltola, and M. A. Siimes
Bleeding and use of blood products after heart operations in infants
J. Thorac. Cardiovasc. Surg., March 1, 1995; 109(3): 524 - 529.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. F. Petry, T. Jost, and H. Sievers
Reduction of homologous blood requirements by blood-pooling at the onset of cardiopulmonary bypass
J. Thorac. Cardiovasc. Surg., May 1, 1994; 107(5): 1210 - 1214.
[Abstract] [Full Text]


Home page
PerfusionHome page
M. Elliott
Minimizing the bypass circuit: a rational step in the development of paediatric perfusion
Perfusion, January 1, 1993; 8(1): 81 - 86.