|
|
||||||||
European Journal of Cardio-Thoracic Surgery, Vol 6, 347-349, Copyright © 1992 by European Association for Cardio-thoracic Surgery
S Nakano, H Matsuda, Y Shimazaki, K Taniguchi, M Kaneko, T Ueda, T Mori and Y Kawashima
To avoid the problem of valve prosthesis/patient mismatch in the late
postoperative period, we have adopted patch enlargement of the small aortic
annulus in 33 patients having undergone aortic valve replacement since
1975, when the aortic annulus could not accept a large enough prosthesis.
The mean age was 40 years, including 2 children aged 4. The technique of
patch enlargement utilized was Nicks' method wherein the incision does not
extend onto the mitral leaflet. In 31 adult patients, the aortic annulus
before enlargement ranged in diameter from 18 to 24 mm with an average of
20.8 mm. After enlargement, the diameter of the annulus was 25.0 mm on
average. In 2 children, the mean diameter of the annulus was enlarged from
16.5 mm to 20.5 mm. There were 2 early deaths in the initial series and 2
late deaths. Patch enlargement of the small aortic annulus is a simple,
safe, and effective adjunct permitting the insertion of a valve one or two
sizes larger than that which could be accommodated by the native annulus.
ARTICLES
An appraisal of patch enlargement of the small aortic annulus in 33 patients undergoing aortic valve replacement
First Department of Surgery, Osaka University Medical School, Japan.
This article has been cited by other articles:
![]() |
K. St. Rammos, D. G. Ketikoglou, G. J. Koullias, S. G. Tsomkopoulos, C. K. Rammos, and N. P. Argyrakis The Nicks-Nunez posterior enlargement in the small aortic annulus: immediate-intermediate results Interactive CardioVascular and Thoracic Surgery, December 1, 2006; 5(6): 749 - 753. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Mohty-Echahidi, J. F. Malouf, S. E. Girard, H. V. Schaff, D. E. Grill, M. E. Enriquez-Sarano, and F. A. Miller Jr Impact of Prosthesis-Patient Mismatch on Long-Term Survival in Patients With Small St Jude Medical Mechanical Prostheses in the Aortic Position Circulation, January 24, 2006; 113(3): 420 - 426. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Pibarot and J. G. Dumesnil Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention J. Am. Coll. Cardiol., October 1, 2000; 36(4): 1131 - 1141. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Lund, K. Emmertsen, T. T. Nielsen, F. T. Jensen, C. Flo, H. K. Pilegaard, B. S. Rasmussen, O. K. Hansen, and L. H. Kristensen Impact of Size Mismatch and Left Ventricular Function on Performance of the St. Jude Disc Valve After Aortic Valve Replacement Ann. Thorac. Surg., May 1, 1997; 63(5): 1227 - 1234. [Abstract] [Full Text] |
||||
![]() |
H. Mayumi, Y. Toshima, Y. Kawachi, K. Tokunaga, and H. Yasui Simplified Manouguian's Aortic Annular Enlargement for Aortic Valve Replacement Ann. Thorac. Surg., September 1, 1995; 60(3): 701 - 704. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |