|
|
||||||||
European Journal of Cardio-Thoracic Surgery, Vol 7, 220-222, Copyright © 1993 by European Association for Cardio-thoracic Surgery
LC John, SJ Edmondson and GM Rees
A method is described whereby individual surgeons may monitor their
coronary graft suturing techniques. The coronary artery anastomotic contour
is measured quantitatively in corrosion resin cast models made of
anastomoses between long saphenous vein and the left anterior descending
coronary artery of a pig's heart. The relevant parameter assessing the
contour is the mean anastomotic narrowing expressed as a percent (MAN%). To
provide an example of the potential of the method, a single surgeon
compared a continuous suture technique (n = 30) with an interrupted one (n
= 30) using corrosion resin models. There was significantly less (P <
0.05) narrowing of the anastomotic contour with the interrupted technique
(mean MAN% = 0.3 +/- 2.9) than with the continuous (mean MAN% = 10.5 +/-
3).
ARTICLES
Coronary artery anastomotic contour--a method for individual surgeons to assess their suture techniques
Department of Cardiothoracic Surgery, St. Bartholomews Hospital, West Smithfield, London, UK.
This article has been cited by other articles:
![]() |
T. C. Dessing, R. P.J. Budde, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound Eur. J. Cardiothorac. Surg., August 1, 2004; 26(2): 257 - 261. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Martens, M. Dietrich, M. Doss, A. Moritz, and G. Wimmer-Greinecker The Heartflo device for distal coronary anastomoses: clinical experiences in 60 patients Ann. Thorac. Surg., October 1, 2002; 74(4): 1139 - 1143. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |