EJCTS Click here to go to Siemens website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grauhan, O.
Right arrow Articles by Hetzer, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grauhan, O.
Right arrow Articles by Hetzer, R.

European Journal of Cardio-Thoracic Surgery, Vol 7, 489-494, Copyright © 1993 by European Association for Cardio-thoracic Surgery


ARTICLES

Intramyocardial electrogram recordings for diagnosis and therapy monitoring of cardiac allograft rejection

O Grauhan, H Warnecke, J Muller, C Knosalla, T Cohnert, A Voss and R Hetzer
German Heart Institute, Berlin.

The registration of intramyocardial ECG amplitudes (IMEG) is a non- invasive diagnostic method of monitoring cardiac allograft rejection. In order to detect possible sources of error IMEG signals were recorded in heterotopic neck hearts in ten beagle dogs. Immunosuppression was based on cyclosporin A. The rejection process was followed by IMEG registrations as well as by serial myocardial biopsies. Intramyocardial electrogram recordings were made via three unipolar and three bipolar leads obtained from screw-in electrodes in both ventricles and the apex of the allograft. A 10% voltage drop was used as an indicator of rejection. In four dogs, the first rejection episode was treated with methyl-prednisolone and the therapy's success was monitored by IMEG and repeat biopsy. At autopsy the histology of each electrode circumference was correlated with the corresponding IMEG. The average sensitivity of a single lead was not acceptable (unipolar: 28%, bipolar: 47%). When the voltages of different leads were summed up the sensitivity rose to 43% (3 x unipolar), 85% (3 x bipolar) and 100% (all leads). During rejection therapy the IMEG recovered within 24-48 h. We conclude that in moderate allograft rejection (grade 2/3a ISHT classification), the rejection-related changes of intramyocardial ECG voltage amplitude (IMEG) seem to follow a "focal pattern" similar to the histology. Therefore the recording of several, preferably bipolar, electrode configurations appears to enhance adequate diagnostic reliability.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
J. E. Everett, M. N. Palmer, J. Jessurun, and S. J. Shumway
Noninvasive Diagnosis of Cardiac Allograft Rejection in an Orthotopic Canine Model
Ann. Thorac. Surg., November 1, 1996; 62(5): 1337 - 1340.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
J. Muller and R. Hetzer
Invited Commentary
Ann. Thorac. Surg., November 1, 1996; 62(5): 1340 - 1341.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1993 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.