European Journal of Cardio-Thoracic Surgery, Vol 8, 160-161, Copyright © 1994 by European Association for Cardio-thoracic Surgery
HG Borst, J Laas and B Buhner
The authors' method for uniting the dissected aortic wall layers with the
help of gelatine-resorcinol adhesive is described focusing on special
instruments used in this conjunction.
ARTICLES
Efficient tissue gluing in aortic dissection
Division of Thoracic and Cardiovascular Surgery, Hannover Medical School, Germany.
This article has been cited by other articles:
![]() |
T. Nakajima, K. Kawazoe, T. Kataoka, H. Kin, T. Kazui, H. Okabayashi, and H. Niinuma Midterm Results of Aortic Repair Using a Fabric Neomedia and Fibrin Glue for Type A Acute Aortic Dissection Ann. Thorac. Surg., May 1, 2007; 83(5): 1615 - 1620. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Bernabeu, M. Castella, C. Barriuso, and J. Mulet Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissection Interactive CardioVascular and Thoracic Surgery, August 1, 2005; 4(4): 329 - 331. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Passage, H. Jalali, R. K.W. Tam, S. Harrocks, and M. F. O'Brien BioGlue surgical adhesive--an appraisal of its indications in cardiac surgery Ann. Thorac. Surg., August 1, 2002; 74(2): 432 - 437. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kazui, N. Washiyama, Abul Hasan Muhammad Bashar, H. Terada, K. Suzuki, K. Yamashita, and M. Takinami Role of biologic glue repair of proximal aortic dissection in the development of early and midterm redissection of the aortic root Ann. Thorac. Surg., August 1, 2001; 72(2): 509 - 514. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Bingley, M. A.H. Gardner, E. G. Stafford, T. K. Mau, P. G. Pohlner, R. K.W. Tam, H. Jalali, P. J. Tesar, and M. F. O'Brien Late complications of tissue glues in aortic surgery Ann. Thorac. Surg., June 1, 2000; 69(6): 1764 - 1768. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Tanaka, S. Takamoto, T. Ohtsuka, Y. Kotsuka, and M. Kawauchi Application of AdvaSeal for acute aortic dissection: experimental study Ann. Thorac. Surg., October 1, 1999; 68(4): 1308 - 1312. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Fukunaga, M. Karck, W. Harringer, J. Cremer, C. Rhein, and A. Haverich The use of gelatin-resorcin-formalin glue in acute aortic dissection type A Eur. J. Cardiothorac. Surg., May 1, 1999; 15(5): 564 - 570. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Sakamoto, H. Arai, and M. Sunamori Surgical Clip for Compression of the Aortic Wall During Gluing Ann. Thorac. Surg., October 1, 1997; 64(4): 1186 - 1187. [Abstract] [Full Text] |
||||
![]() |
P. Mastroroberto, M. Chello, and T. Carrel Embolization of Biological Glue After Repair of Acute Aortic Dissection Ann. Thorac. Surg., September 1, 1996; 62(3): 946 - 947. [Full Text] |
||||
![]() |
T. Carrel, M. Maurer, T. Tkebuchava, U. Niederhauser, J. Schneider, and M. I. Turina Embolization of Biologic Glue During Repair of Aortic Dissection Ann. Thorac. Surg., October 1, 1995; 60(4): 1118 - 1120. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |