EJCTS Click here to locate an Ethicon representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vrandecic, M. P.
Right arrow Articles by Barbosa, M. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vrandecic, M. P.
Right arrow Articles by Barbosa, M. R.

European Journal of Cardio-Thoracic Surgery, Vol 9, 69-73, Copyright © 1995 by European Association for Cardio-thoracic Surgery


ARTICLES

Heterologous mitral valve transplant: the first 50 patients clinical analysis

MP Vrandecic, BF Gontijo, FA Fantini, C Gutierrez, EO Peredo, JA Paula e Silva, JT Barbosa, IC Martins, MA Braga and MR Barbosa
Biocor Institute, Belo Horizonte, MG, Brazil.

From March 1992 to August 1993, 50 patients underwent mitral valve replacement with the new heterologous stentless mitral bioprosthesis in our institution. The development of this heart valve substitute, its technique of implantation and the results observed in the first group of 50 patients have had us to review the initial experience. The surgical protocol included an accurate mitral valve complex analysis, adequate valve size selection, attachment of the papillary muscle to the new chordal origin and approximation of the stentless mitral to the patient's annulus. There was one hospital death (2%), not related to the valve or to the technique and four reoperations: two due to endocarditis, one because of a perivalvular leak and one due to a mismatched stentless valve. The late mortality (4%) was not valve- related. The follow-up has shown excellent valve performance with improved left ventricular function in the great majority of the patients. Based on the current analysis, it can be stated that reproducibility of the surgical technique and the excellence of the clinical follow-up may contribute favorably to a better quality of life and longer valve durability in patients requiring mitral heart valve replacement.


This article has been cited by other articles:


Home page
CirculationHome page
T. Walther, C. Walther, V. Falk, A. Diegeler, R. Krakor, J. Schneider, R. Autschbach, and F. W. Mohr
Early Clinical Results After Stentless Mitral Valve Implantation and Comparison With Conventional Valve Repair or Replacement
Circulation, November 9, 1999; 100(90002): II-78 - 83.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Bernal, J. M. Rabasa, J. C. Cagigas, F. Val, and J. M. Revuelta
Behavior of Mitral Allografts in the Tricuspid Position in the Growing Sheep Model
Ann. Thorac. Surg., May 1, 1998; 65(5): 1326 - 1330.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Prof. M. Vrandecic, Prof. B. Gontijo, and Prof. F. Fantini
Homograft replacement of the mitral valve
J. Thorac. Cardiovasc. Surg., December 1, 1996; 112(6): 1678 - 1680.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1995 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.