EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barnard, S. P.
Right arrow Articles by Dark, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barnard, S. P.
Right arrow Articles by Dark, J. H.

European Journal of Cardio-Thoracic Surgery, Vol 9, 297-299, Copyright © 1995 by European Association for Cardio-thoracic Surgery


ARTICLES

Mechanical ventricular assistance for the failing right ventricle after cardiac transplantation

SP Barnard, A Hasan, J Forty, CJ Hilton and JH Dark
Department of Cardiothoracic Surgery, Freeman Road Hospital, Newcastle- on-Tyne, UK.

Right ventricular failure secondary to elevated pulmonary vascular resistance (PVR) following orthotopic cardiac transplant is a complication with a high mortality; and patients with high resistance are often not accepted on transplant waiting lists. We describe six cases of right ventricular failure after cardiac transplant managed by right ventricular assist device (RVAD), four of whom died and two patients who survived following life-threatening complications.


This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
S. Saleh, O. J. Liakopoulos, and G. D. Buckberg
The septal motor of biventricular function
Eur. J. Cardiothorac. Surg., April 1, 2006; 29(Suppl_1): S126 - S138.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
C. Wiesenack, C. Prasser, A. Liebold, and F. X Schmid
Assessment of left ventricular cardiac output by arterial thermodilution technique via a left atrial catheter in a patient on a right ventricular assist device
Perfusion, January 1, 2004; 19(1): 73 - 75.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. A. Petrofski, V. S. Patel, S. D. Russell, and C. A. Milano
BVS5000 support after cardiac transplantation
J. Thorac. Cardiovasc. Surg., August 1, 2003; 126(2): 442 - 447.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. E. Arafa, O. R. Geiran, K. Andersen, E. Fosse, S. Simonsen, and J. L. Svennevig
Intraaortic balloon pumping for predominantly right ventricular failure after heart transplantation
Ann. Thorac. Surg., November 1, 2000; 70(5): 1587 - 1593.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. Minami, Y. Bonkohara, L. Arusoglu, A. El-Banayosy, and R. Korfer
New technique for the outflow cannulation of right ventricular assist device
Ann. Thorac. Surg., September 1, 1999; 68(3): 1092 - 1093.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1995 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.