|
|
||||||||
Eur J Cardiothorac Surg 2003;23:194-199
© 2003 Elsevier Science NL
a Department of Thoracic Surgery, K
r
kkale University School of Medicine, 71100 K
r
kkale, Turkey
b Department of Biochemistry, Hacettepe University School of Medicine, 06100 S
hh
ye, Ankara, Turkey
c Department of Thoracic Surgery, Ankara Oncology Hospital, 06100 Demetevler, Ankara, Turkey
Received 3 September 2002; received in revised form 15 October 2002; accepted 1 November 2002.
* Corresponding author. Güvenlik caddesi, Esenlik sokak 7/10, TR-06540 A
a
ayranc
, Ankara, Turkey. Tel.: +90-318-225-4511; fax: +90-318-225-2819
e-mail: muratkara66{at}hotmail.com
Objective: Definitive diagnosis of lung cancer with conventional methods may sometimes be difficult in clinical practice. Telomerase is a ribonucleoprotein DNA polymerase that maintains the telomeric region of chromosomes during successive rounds of cell division. Telomerase activity in body cavity fluids has been advocated to be a potential diagnostic marker for malignancy. We investigated the diagnostic value of telomerase activity in bronchial lavage samples of patients undergoing diagnosis of lung cancer. Methods: A total of 29 bronchial lavage samples were collected from patients in whom the diagnosis was confirmed with cytological and/or histological examinations. Patients were classified as lung cancer patients (Group 1, n=22) and patients with benign disease (Group 2, n=7). Telomerase activity was determined with polymerase chain reaction-based TRAP (The telomeric repeat amplification protocol) assay. Results: Cytological examination was diagnostic in 12 (54.5%) of 22 patients in Group 1, and in all seven patients of Group 2 (P=0.063). Telomerase activity was positive in 16 (72.7%) of Group 1 patients, while it was positive in only 1 (14.3%) sample of a lung abscess in Group 2 (P=0.011). The sensitivity rate of cytological examination when combined with telomerase activity (81.8%) was significantly greater than that of cytological examination alone (54.5%) (P=0.031). The sensitivity and specificity of telomerase activity were 72.7 and 85.7%, respectively. Telomerase activity had a positive predictive value as 0.94 and negative predictive value as 0.50. Diagnostic accuracy of telomerase activity was 75.8%. Conclusion: Telomerase activity in bronchial lavage is a highly sensitive diagnostic biomarker for malignancy and a potential complementary diagnostic technique to cytological examination in the diagnosis of lung cancer.
Key Words: Telomerase Lung cancer Bronchial lavage
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |