EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Urbanski, P. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Urbanski, P. P.
Related Collections
Right arrow Valve disease

Eur J Cardiothorac Surg 2001;20:1275-1276
© 2001 Elsevier Science NL


Letter to the Editor

Valved stentless composite graft

Paul P. Urbanski

Herz- und Gefaess-Klinik, 97616 Bad Neustadt, Germany

Received 30 August 2001; accepted 11 September 2001.

Tel.: +49-9771-662-416; fax: +49-9771-651-219
e-mail: urbanski{at}kardiochirurg.de

I have read the article by Byrne et al. [1] with interest. The authors mention my operation technique in their discussion [2,3] and suggests that, ‘Because the valve is placed 3 mm above the level of the annulus, one must be very careful about the placement of the coronary buttons on the tube graft, because the buttons will either be very close to the valve or potentially kink due to the 3 mm displacement. In Urbanski and Hacker's report they describe a 10% (2/20) incidence of the need for CABG because of technical complications’ [1]. This claim is incorrect and may be based on lack of understanding of the operation technique described.

The 3 mm margin of the Dacron tube is only intended for the fixation of the conduit to the aortic annulus and, due to the everted suturing technique, does not cause any dislocation of the valve prosthesis away from the annulus (Fig. 1) . The technical problems that led to CABG are clearly stated in the article, ‘The bypass grafts were performed in five patients to address coronary heart disease and in the other two for the technical reason that re-implantation of the right coronary ostium did not seem feasible because of calcification of the aortic wall’ [3].



View larger version (12K):
[in this window]
[in a new window]
 
Fig. 1. The stentless valve prosthesis (Toronto SPV, St. Jude Medical, St. Paul, MN) is placed inside the vascular tube and attached with a continuous suture (dotted line). The conduit is anastomosed to the aortic annulus by supraannular technique. The proximal 3 mm margin of the Dacron tube is everted.

 
Incidentally, one of the two patients was among the first six who were operated on before modification of the technique. The second belonged to the group of 47 patients in whom the modified technique was used for operation. The re-implantation of the coronary buttons did not otherwise cause any problems.

There are two reasons why I moved the valve prosthesis into the Dacron tube. The first is that in a xenograft, as in a homograft, calcification may occur not only in the cusps, but also in the aortic wall. This calcification of the aortic wall can make reoperation extremely difficult if a change of valve is necessary.

Secondly, this technique avoids an additional anastomosis between the xenograft and the Dacron tube. If the prosthesis of the ascending aorta is even slightly too long, then a kink stenosis can form. Such a complication appears not to be infrequent. In recent weeks, I have re-operated two patients with replacement of the ascending aorta who exhibited such kinks (Fig. 2) . In order to avoid stenosed kinking of the Dacron prosthesis, it must be cut so that it just fits and must be anastomosed under a certain degree of tension. This in turn leads to the potential risk of increased bleeding and even to tissue dehiscence at the xenograft, which we have already seen on one occasion [2,4]. The use of a biological adhesive to strengthen the sutures, as Byrne does, can reduce risk, but does not facilitate reoperation, an option that the surgeon should always bear in mind, especially when using a biological conduit. In Byrne's group of patients, of whom almost 40% were under 65 years of age, this may be an important aspect.



View larger version (174K):
[in this window]
[in a new window]
 
Fig. 2. The Dacron prosthesis of the ascending aorta is too long and forms a kink stenosis.

 
Apart from one patient with acute aortic dissection, I have not used any biological adhesives in any other case (46). The rethoracotamy rate was 2.1% (1/47) vs. 25% (2/8) as reported by Byrne.

In our series of 47 consecutive patients there were two (4.3%) acute dissections, three (6.4%) re-operations and 14 (30%) concomitant operations (11xCABG and 3x mitral valve repair or replacement). During the follow-up period of up to three years, 45 survivors (there were two non-cardiac and non-valve-related deaths) had very good hemodynamic results with normal motility of the aortic cusps showing no contact with the Dacron tube, low gradient across the valve and no regurgitation.

I agree that the method I described is technically demanding, although this is not obvious from the cross-clamp time (median 108 vs 150 min). For surgeons who are practised in valve-sparing aortic replacement, however, it should not present any problems. I find this surgical challenge, nevertheless, worthwhile as in the long run it is beneficial to patients.

References

  1. Byrne J.G., Mihaljevic T., Lipson W.E., Smith B., Fox J.A., Aranki S.F. Composite stentless valve with graft extension for combined replacement of the aortic valve, root and ascending aorta. Eur J Cardiothorac Surg 2001;20:252-256.[Abstract/Free Full Text]
  2. Urbanski P.P. Replacement of the ascending aorta and aortic valve with a valved stentless composite graft. Ann Thorac Surg 1999;67:1501-1502.[Abstract/Free Full Text]
  3. Urbanski P.P., Hacker R.W. Replacement of the aortic valve and ascending aorta with a valved stentless composite graft: technical considerations and early clinical results. Ann Thorac Surg 2000;70:17-20.[Abstract/Free Full Text]
  4. Urbanski P.P. Replacement of the ascending aorta and aortic valve with a valved stentless composite graft (Reply to the editor). Ann Thorac Surg 1999;68:1444.[Free Full Text]



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. P. Urbanski
New Vascular Graft for Assembling the Stentless Valve Composite Graft
Ann. Thorac. Surg., November 1, 2007; 84(5): 1771 - 1773.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Urbanski, P. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Urbanski, P. P.
Related Collections
Right arrow Valve disease


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS