|
|
||||||||
Eur J Cardiothorac Surg 2002;21:683-691
© 2002 Elsevier Science NL
a Department of Cardio-Thoracic Surgery, Bd162 and the Center for Clinical Decision Making, Erasmus Medical Center Rotterdam, P.O. Box 2040, 3000CA Rotterdam, The Netherlands
b Department of Public Health, Erasmus Medical Center Rotterdam, P.O. Box 2040, 3000CA Rotterdam, The Netherlands
Received 14 September 2001; received in revised form 14 December 2001; accepted 3 January 2002.
* Corresponding author. Tel.: +31-10-463-5413; fax: +31-10-463-3993
e-mail: takkenberg{at}thch.azr.nl
| Abstract |
|---|
|
|
|---|
Key Words: Allograft Aortic valve replacement Surgical technique Preservation technique
| 1. Introduction |
|---|
|
|
|---|
Ross initially employed the subcoronary implantation technique with good results. However, in the hands of less experienced surgeons early technical failure requiring reoperation was observed [2,3]. Nowadays, most centers use cryopreserved aortic allografts and employ the root replacement implantation technique with reimplantation of the coronary arteries [46]. A major advantage of this technique is the preservation of the aortic root geometry, minimizing initial regurgitation [7]. On the other hand, it requires radical root resection with the risk of complications associated with the reimplantation of the coronary arteries. In addition, on the long term the root may calcify and cause loss of aortic root compliance and an increased risk of leaflet damage caused by contact with the calcified root. Finally, replacement of allograft roots may be more complicated compared to subcoronary implanted allografts.
Also with regard to preservation and sterilization techniques changes have taken place over the years. Most centers now use cryopreserved valves, with the advantage of a long shelf half-life time. Whether the durability of cryopreserved valves is better compared to fresh 4°C antibiotic stored allograft valves remains unclear [4]. The role of immunologic processes in allograft valve failure is still under debate, and although both cryopreserved and fresh allografts elicit a donor-reactive immune response there is (yet) no clear clinical evidence of associated increased allograft valve failure [8,9].
We present our center's experience with the use of allografts for aortic valve or root replacement, illustrating the impact on outcome of the changes made in surgical and preservation techniques.
| 2. Materials and methods |
|---|
|
|
|---|
|
|
2.4. Follow-up
All patients were prospectively followed over time either through the outpatient clinic and/or by means of an annual telephone survey. Standardized echocardiographic follow-up was done as described previously [3]. Mean duration of follow-up was 4.8 years (SD 3.6 years), ranging from 0 days to 13.8 years. Total follow-up was 1315 patient years, and 99% complete. Morbidity and mortality during follow-up were defined according to the 1996 guidelines for reporting morbidity and mortality after cardiac valvular operations [12].
2.5. Statistical methods
Data are expressed as mean±1 SD. Means were compared by the unpaired t-test. The
2-test or Fisher's exact test was used to compare categorical variables. All tests were 2-sided, with an
-level of 0.05. Logistic regression was used to study potential determinants of early mortality (death during hospitalization or within 1 month after operation). Multiple logistic regression was used to study independent determinants for early mortality. The final model was obtained using the stepwise backward method with criteria for entry P<0.05 and removal P>0.10. Cumulative survival and freedom from reoperation were analyzed using the KaplanMeier method. The survival of a patient started at the time of aortic valve operation and ended at death (event) or at last follow-up (censoring). The analysis of allograft survival started at the time of implantation and ended with reoperation (event) or last follow-up or patient death (censoring). The differences between KaplanMeier curves were evaluated using the log-rank test. Multivariate analysis of time-related events (death, reoperation, and reoperation for structural valve deterioration) was done using the Cox proportional hazard regression model. Backward stepwise selection of potential predictors (criteria for entering variables: log-rank
2-test P<0.05) was employed. Covariables were examined by complete case analysis. The incidence of structural valve deterioration requiring reoperation was described by a Weibull curve, which is a generalization of the exponential distribution that accommodates a changing risk over time [1315]. An age parameter that was based on the observed relationship between patient age and structural valve deterioration was added to the Weibull model, allowing for patient age-specific calculations for structural valve deterioration [16,17].
| 3. Results |
|---|
|
|
|---|
|
3.1. Long-term mortality
During follow-up another 29 patients died. Of these patients 21 died of non-valve-related causes. Six patients died sudden unexpected and unexplained deaths, one patient died due to a major bleeding, and one patient died of acute heart failure caused by severe aortic insufficiency while waiting for reoperation of a degenerated aortic allograft 7.9 years after the initial procedure. Overall cumulative survival including early survival was 93% at 1 year (95% CI 9096%), 87% at 5 years (95% CI 8392%), and 73% at 9 years postoperative (95% CI 6681%). In Fig. 1
cumulative survival for patients operated with the subcoronary implantation technique and the root replacement technique is displayed separately (Log-rank test P=0.006). Independent risk factors for overall mortality were older patient age >40 years (HR 3.6, 95% CI 1.77.5; P=0.001), root replacement technique (HR 2.2, 95% CI 1.14.7; P=0.04), preoperative heart rhythm other than sinus rhythm (HR 1.9, 95% CI 1.32.7; P<0.001), longer perfusion time (in minutes, HR 1.0, 95% CI 1.01.0, P=0.02), diabetes mellitus (HR 3.0, 95% CI 1.18.3; P=0.03), and preoperative ventilatory support (HR 4.1, 95% CI 1.312.9; P=0.02).
|
|
In the other 19 patients structural valve deterioration caused by degeneration of the allograft was the reason for replacement of the allograft. This occurred in 12 patients in the SC group and in seven patients in the ARR group. The allograft was replaced by a mechanical valve in 14 patients, an allograft in three patients (one subcoronary implantation; two root replacement), and a modified autograft procedure was performed in two patients. Freedom from reoperation for structural valve deterioration caused by degeneration of the allograft (N=19) was 97% at 5 years (95% CI 93100), 89% at 7 years (95% CI 8595%) and 83% at 9 years postoperative (95% CI 7591%). The results of the univariate and multivariate analyzes of potential determinants of degenerative structural valve deterioration are displayed in Table 4. Independent predictors of structural valve deterioration requiring reoperation were younger patient age at the time of operation, the use of fresh allografts, larger allograft diameter, and older donor age. Mean age at the time of operation of those patients requiring reoperation for degenerative structural valve deterioration (N=19) was 33 years (SD 12; range 1457 years). In Fig. 3 the Weibull function representing the effect of patient age on freedom from structural valve deterioration is displayed. For example, for a 45-year-old patient median time to reoperation for structural allograft valve deterioration was 16.5 years.
|
|
| 4. Discussion |
|---|
|
|
|---|
Important predictors of early mortality were patient age and impaired preoperative renal function, and confirm the findings by Lund et al. [5]. Procedure-related coronary artery bypass grafting was also associated with increased early mortality (two of the six patients; OR 13.1). This operative complication is restricted to root replacement and related to the reimplantation of the coronary arteries that is necessary using this technique.
Overall survival was better in patients operated with the subcoronary technique compared to the root replacement technique, reflecting the change in patient profile that took place over the years. This is contradictory to what Lund et al. report [5], and also not supported by the experience from O'Brien's group [4]. It can be explained by the fact that the patient populations of these other centers consist of relatively more patients with isolated valve disease, while only a minority presents with aortic root disease and/or endocarditis.
As has been reported previously [35] younger patient age is the most important predictor of structural valve deterioration. This is confirmed by our findings. In addition, we used a Weibull model to calculate long-term freedom from reoperation for structural valve deterioration based on our current midterm results. It should be stressed that the estimates from the Weibull model are based on the assumption that the risk of structural valve deterioration increases with time. Therefore, the estimates beyond 13 years are still hypothetical and will require regular validation and refinement using the growing experience with allografts worldwide. Currently, using the Weibull model the calculated median time to reoperation for structural valve deterioration varies from 23 years in a 65-year-old patient down to 12 years in a 25-year-old (Fig. 3). This reflects the need for improvement of the durability of the allograft, and also raises the question whether allografts are the preferred aortic valve substitute in the younger age groups. In these patients other valve substitutes should be seriously considered. In our center, children who require surgical treatment of their aortic valve disease preferably undergo valvotomy or a modified autograft procedure. We reported previously that in patients after autograft aortic root replacement calculated median time to explantation of the autograft for structural valve deterioration was 25 years [18], much better than the estimates derived from our allograft population. Also, no relation between autograft structural valve deterioration and patient age was observed. On the other hand, there is yet little information on the durability of the allograft in the right ventricular outflow tract after autograft aortic root replacement. This is a factor that may be of influence when considering the durability of the autograft procedure. In selected patients a mechanical valve is also a good alternative to the allograft. We previously showed that in younger patients with mechanical bileaflet prostheses the impact of bleeding and thrombo-embolic complications is relatively low, since the life expectancy of these patients is markedly reduced and they will not reach older age where these events become important determinants of outcome [19].
According to our findings, older donor age is also a predictor of structural valve deterioration. Lund et al. previously described that the difference between donor age and patient age is the most important determinant for tissue failure after aortic valve replacement with homovital allografts [5]. We did not attempt to investigate this factor in our model, since in our opinion it combines two separate risk factors for allograft structural valve deterioration. Younger patient age is an approximation of an increased workload on the allograft and possibly an increased immune response, while older donor age represents the aging and wear out of the valve substitute. Although donor age is not (yet) a very strong risk factor for structural valve deterioration, it may be advisable to preferably use allografts from younger donors, at the least in the younger patient group.
Other well-known risk factors for structural valve failure in our series were large diameter of the allograft and the use of pulmonary allografts. With the introduction of the root replacement technique, matching of the size of the allograft to the recipient aortic annulus has become less important. Nevertheless, in the multivariate analysis larger allograft size still was an important predictor of allograft structural valve failure independent of patient age and surgical technique. Further investigation into the possible causes that could explain this observation is necessary.
Our experience with fresh wet-stored allograft valves (N=7) is limited, and we find no difference in the durability of fresh compared to cryopreserved allografts. Previous reports tended to be in favor of cryopreserved over fresh valves with regard to durability [20,21]. However, a recent publication from O'Brien and colleagues [4] shows that in their extensive experience with over 1000 implantations the freedom from structural valve deterioration at 20 years is similar for cryopreserved and 4°C anti-biotic stored valves.
Another issue that is often being raised is the influence of surgical technique on the durability of the allograft in aortic position. We have shown previously that the subcoronary implantation technique has a surgeon's learning curve that results in more initial aortic regurgitation and early reoperation compared to the root replacement technique [3]. The progression of aortic regurgitation over time is small in both techniques and it yet remains unclear whether and how the surgical technique will influence durability. The high incidence of early technical failure with the subcoronary implantation technique in our center, and the potential advantage of the preservation of the aortic root geometry using aortic root replacement, has led us to nowadays only use the root replacement technique. It is however a more extensive operation that requires reimplantation of the coronary arteries with the potential complication of coronary malperfusion. Therefore it is essential to pay close attention to the sizing of the coronary buttons and to carefully select the reimplantation site to avoid kinking or stretching of the reimplanted coronary artery. From our current study, we still observe the early increased reoperation rate due to technical failure in the subcoronary implantation group, and thereafter progression of structural valve deterioration is similar to that of the root replacement group. There may however be evidence in favor of the subcoronary implantation technique over the root replacement technique with regard to long-term freedom from reoperation, when carefully studying O'Brien's most recent update of the pioneer series from Australia [4].
With regard to the other valve-related events after allograft aortic valve replacement that were observed in this prospective ongoing study, it can be stated that these occur infrequently. In this respect the allograft is far superior to mechanical and bioprosthetic valves.
In conclusion, we have shown that aortic valve replacement with allografts yields adequate midterm results. Although important changes have been made over the years to improve durability, allografts still have a limited life span especially in young patients. Effort should be made to improve the durability of this valve substitute and to optimize the use of allografts. Most importantly, given the current evidence other aortic valve substitutes should be seriously considered in younger patients.
| Acknowledgments |
|---|
| Footnotes |
|---|
| Appendix A. Conference discussion |
|---|
|
|
|---|
Dr Takkenberg: The relationship between younger patient's age and structural valve deterioration is not only apparent in our series but also the series from Brisbane, Australia, and also Yacoub has shown that there is an age relationship with structural valve deterioration. We would recommend for the younger age groups to also consider the autograft procedure, but also mechanical valves may be a good option in selected patients.
Dr A. Haverich (Hannover, Germany): I think this is a very important series. The question I had when looking at the long-term survival rates of those with subcoronary implants and root implants is that the late mortality was so high in the root replacement group, and the question arises to me, because reoperation on these patients is not always funny, whether structural valve degeneration cases might be hidden in this late mortality?
Dr Takkenberg: What we find is in contradiction to what other series find. For instance, in the Brisbane series from O'Brien, survival in patients with root replacement is better compared to the subcoronary technique, and also Yacoub has stated that recently in London earlier this year at the Society of Heart Valve disease meeting. There may be some hidden structural valve degeneration in the mortality in our series. I recall at least one patient who died shortly before reoperation.
Dr B. Messmer (Aachen, Germany): Could you just say a few words about the pulmonary homograft which did not give as good results as apparently the aortics? What was the type of degeneration in the pulmonary homograft? Was it insufficiency or was it also degeneration of the calcification type?
Dr Takkenberg: We used pulmonary allografts mainly early in our series, so they were implanted with the subcoronary technique. Mainly insufficiency was seen and in some cases it was caused by degeneration.
Dr Wolner: Do you have any data that homografts harvested from younger hearts have a better durability than homografts from older, because you suggested to use in young patients young homografts?
Dr Takkenberg: Yes, that's right, we found that older donor age is a predictor of early structural valve deterioration. We used age as a continuous variable. I would prefer to use younger donor valves in younger patients. In my opinion, younger donor valves have a longer life span compared to older donor valves, since older donor valves they have already been in a different person for a long time. So it is I guess a matter of durability of the valve substitute.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
A. Ali, Y. Abu-Omar, A. Patel, A. Y. Sheikh, Z. Ali, A. Saeed, A. Akhtar, T. Athanasiou, and J. Pepper Propensity analysis of survival after subcoronary or root replacement techniques for homograft aortic valve replacement. J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 334 - 341. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Ali, Y. Abu-Omar, A. Patel, Z. Ali, A. Y. Sheikh, A. Akhtar, A. Pavlovic, P. Theodorou, T. Athanasiou, and J. Pepper Valve failure following homograft aortic valve replacement: does implantation technique have an effect? Eur. Heart J., June 1, 2008; 29(11): 1454 - 1462. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J.M. Takkenberg, L. M.A. Klieverik, J. A. Bekkers, A. P. Kappetein, J. W. Roos, M. J.C. Eijkemans, and A. J.J.C. Bogers Allografts for aortic valve or root replacement: insights from an 18-year single-center prospective follow-up study Eur. J. Cardiothorac. Surg., May 1, 2007; 31(5): 851 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. J. Geissler, U. M. Fischer, S. Foerster, A. Krahwinkel, A. Antonyan, A. Kroener, K. Addicks, U. Mehlhorn, and W. Bloch Effect of Thawing on Nitric Oxide Synthase III and Apoptotic Markers in Cryopreserved Human Allografts Ann. Thorac. Surg., November 1, 2006; 82(5): 1742 - 1746. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. P. Kappetein, J. J.M. Takkenberg, J. P.A. Puvimanasinghe, W.R. E. Jamieson, M. Eijkemans, and Ad.J.J.C. Bogers Does the type of biological valve affect patient outcome? Interactive CardioVascular and Thoracic Surgery, August 1, 2006; 5(4): 398 - 402. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Athanasiou, C. Jones, R. Jin, G. L. Grunkemeier, and D. N. Ross Homograft Implantation Techniques in the Aortic Position: To Preserve or Replace the Aortic Root? Ann. Thorac. Surg., May 1, 2006; 81(5): 1578 - 1585. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kaya, M. A. Schepens, W. J. Morshuis, R. H. Heijmen, A. Brutel De La Riviere, and K. M. Dossche Valve-Related Events After Aortic Root Replacement With Cryopreserved Aortic Homografts Ann. Thorac. Surg., May 1, 2005; 79(5): 1491 - 1495. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Dagenais, P. Cartier, P. Voisine, D. Desaulniers, J. Perron, R. Baillot, G. Raymond, J. Metras, D. Doyle, and P. Mathieu Which biologic valve should we select for the 45- to 65-year-old age group requiring aortic valve replacement? J. Thorac. Cardiovasc. Surg., May 1, 2005; 129(5): 1041 - 1049. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-M. Grinda, J.-L. Mainardi, N. D'Attellis, M.-O. Bricourt, A. Berrebi, J.-N. Fabiani, and A. Deloche Cryopreserved Aortic Viable Homograft for Active Aortic Endocarditis Ann. Thorac. Surg., March 1, 2005; 79(3): 767 - 771. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Iung, G. Baron, E. G. Butchart, F. Delahaye, C. Gohlke-Barwolf, O. W. Levang, P. Tornos, J.-L. Vanoverschelde, F. Vermeer, E. Boersma, et al. A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease Eur. Heart J., July 1, 2003; 24(13): 1231 - 1243. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |