|
|
||||||||
Eur J Cardiothorac Surg 2002;21:864-868
© 2002 Elsevier Science NL
Division of Thoracic Surgery, Cardiac and Thoracic Department, University of Pisa, Via Paradisa 2, 56124 Pisa, Italy
Received 14 September 2001; received in revised form 1 February 2002; accepted 11 February 2002.
* Corresponding author. Tel.: +39-50-995211; fax: +39-50-995-7239
e-mail: f.melfi{at}med.unipi.it
| Abstract |
|---|
|
|
|---|
Key Words: Robotic surgery Thoracoscopy Video-assisted thoracoscopy
| 1. Introduction |
|---|
|
|
|---|
Currently two robotics systems are used in clinical practice (cardiac and general surgery), the differences of which have been described in the literature [24]. Although there is a real difference between thoracic and cardiac surgery and systems have been developed for cardiac bypass, an application in the field of thoracic surgery seems realistic.
The Da Vinci robotic system became available in our institution in February 2001. This system consists of two components: (1) a master console where the surgeon sits comfortably, using a 3-D vision and handling telemanipulators and optical controls; (2) a surgical arm cart which moves the instruments. The movements of the surgeon's hands are transmitted without any delay to the tips of the two robotic arms. The main technical advantages of this system are scaling, indexing and tremor filtration [1]. Consequently, surgical precision and accuracy are the real benefits of this technique.
No information was available regarding the clinical applicability of this robotic device to the thoracoscopic procedures when we started our program. After a period of technical development and training using animal models, we made use of the robotic system to treat patients with various pulmonary diseases. We have focused our efforts on the development of this technique in the field of the thoracic surgery. Particularly, we assessed the advantages and limits of using the robotic surgery to perform thoracoscopic lung procedures.
| 2. Methods |
|---|
|
|
|---|
Procedures included five lobectomies (three left and two right lower lobe lobectomy), three tumor enucleations (one tuberculoma and two chondroma), three tumor excisions (fibrotic pleural tumor, enteric cyst, leiomyoma) and one bulla stitching completed with fibrin glue for spontaneous pneumothorax (Table 1). After obtaining written informed consent from the patients, we performed the operations using the Da Vinci Robotic System (Intuitive Surgical Inc., CA, USA). All members of the surgical team (surgeons, scrub nurses and technicians) had to undertake specific training. After an initial theoretical phase, training at the console was the surgeon's first impact with robotic surgery. In the subsequent training phase animal models were used. The learning curve was relatively short, since the surgeons had a solid background in thoracoscopic surgery.
|
Two master handles at the surgeon's console are manipulated by the user. The position of the surgeon's hands on the handles trigger highly sensitive motion sensors which transfer the surgeon's movements to the tip of the instrument at a remote location. The surgeon sits at the master console, located at a distance from the patient, with his eyes focused downwards toward the operative field which appears as in open surgical technique, and the robotic unit provides a tele-presence within the chest for micro-instrument manipulation.
A high-resolution 3-D, 0° or 30° scope, with two 3-chip cameras (CCD) is used for better depth perception and optical resolution. The scope is held by the central four DOF (degree of freedom) manipulator of a remote centre surgical cart. Independently, acquired images are transmitted to a high-resolution binocular display of the operative field (the operative image magnification may be up to ten times the actual size).
Movements exerted on the handles are sensed by high-resolution motion sensors, which process them and transfer them to the two surgical manipulators. These surgical arms provide three degrees of freedom (pitch, yaw, insertion). Attached to the surgical arm is the surgical instrument, the tip of which is provided with a mechanical wrist (EndoWrist) which adds four more degrees of freedom (internal pitch, internal yaw, rotation and grip).
In order to increase precision, a motion filter built into the system eliminates unintended movements caused by human tremor.
2.2. Operative technique
All operations were performed by the same surgeon and an assistant surgeon was on hand if needed. The patients were placed in the lateral position with general anaesthesia and single-lung ventilation.
During the operations the main body of the machine was placed behind the operative site and the best position of robotic-arms was established in relation to the side of the lesion. The first thoracoport (12 mm) was placed for the 0° 3-D scope and the other two thoracoports (10 mm) were used for the placement of the right and left instrument-arms (Fig. 1) . Correct placement of the robotic cart and the trocars is mandatory in order to avoid collision between the mechanical arms and to optimize system performance: in particular the trocars must be positioned at a greater distance from each other than they normally would be in standard thoracoscopic surgery.
|
For the lesions located in a lower right position, the ports were placed in a similar position as that of the left-side operations.
In the enteric cyst and in the leiomyoma the arms were placed in a different position: the scope was inserted in the eighth left intercostal space (posterior line) and in the seventh right intercostal space (midaxillary line), respectively; the arms were placed in the fifth and sixth intercostal space (at posterior and anterior axillary line) and in the fifth and seventh space (at posterior axillary line), respectively.
2.3. Lobectomy procedure
For the lobectomy procedures (left and right lower lobectomies) a service entrance (3 cm) was made in the fourth intercostal space. Two additional thoracoports were inserted in the seventh and sixthseventh intercostal spaces at the mid- and post-axillary line, respectively.
The service entrance served for the right robotic instrument, and was also useful as a site to insert standard endoscopic instruments, when the robotic instruments were not suitable. Dissection of structures was performed with a combination of electrocautery and DeBakey forceps mounted on the robotic arms. Blunt dissection was particularly useful when dissecting around the pulmonary vessels and for sweeping tissue along the lobar bronchus peripheral to the line of intended bronchial division so that all the lobar bronchial nodes could be included in the operative specimen. In the right lower lobectomy the apical lower segmental artery and the main trunk was divided by stapling (Endopath TSW 35 mm vascular/thin; Ethicon Inc.). The lower lobe was retracted anteriorly (with traditional endoscopic forceps through the service entrance) and the pulmonary ligament incised to expose the lower vein, which was cleared of surrounding tissue and divided by stapling. The lobe was then retracted inferiorly and the anterior portion of the oblique fissure (between the middle and lower lobes) divided using electorocautery.
Finally, the lower lobe bronchus was divided by stapling (Endopath ATB45 Ethicon Endo-Surgery Inc.), with care being taken to preserve the middle lobe origin.
In the left lower lobectomy the apical lower and main-stem lower vessels were taken separately. In this case, a suture ligation was used with Linen 2.5 (Fig. 2) . The pulmonary ligament was incised, and the lower vein cleared and divided. We gently placed a clamp vascular, and using arm-instruments (DeBakey Forceps and Micro Forceps) we stitched (polypropylene monofilament 4/0) on the transected lower vein. The clamp was removed when the closure was seen to be secure. The resected lobes were removed in sterile plastic bags through the service entrance, without a rib spreader.
|
At the end of the operations the robotic arms were removed from the chest and two drains were inserted through the ports sites, into the chest cavity.
| 3. Results |
|---|
|
|
|---|
None of the patients had problems related to post-operative bleeding. All patients tolerated the procedure well and the post-operative course was satisfactory, requiring fewer analgesics. Chests tubes were removed after a mean of 2 post-operative days and the patients were discharged after a mean of 4 post-operative days.
Three patients, with lung cancer (one), typical carcinoid (one) and chondroma (one), required a minimal thoracotomy. We began the operations with the robotic technique which allowed us to isolate and stitch on the transected lower vein in the first two patients. We had to complete the operations using the service entrance (enlarged by about 2 cm) due to hilar calcified lymph nodes, since these rendered the dissecting of the interlobar pulmonary artery unsafe. With the third patient, a small radiolabelled pulmonary nodule (<1 cm) was not detected with a gamma-ray detector. We had to enlarge the service entrance so as to detect the lesion tactically and then we completed the operation with the robotic system.
All patients were discharged in good condition and returned to pre-operative levels of physical activity within 10 days of the operation.
| 4. Discussion |
|---|
|
|
|---|
Although this technology holds great promise, there are still major technical hurdles that can affect the dexterity of the surgeon and add to the complexity of the procedure [711]. The current robot manipulator system requires larger and bulkier instruments to obtain the seven degrees of freedom within the body cavity and the system's size limits access to the patient by the surgical assistant [11,13]. The physical orientation and the optimal working angles between instruments, the lesion's plane and the angle of the vision are important issues that must be considered when planning a closed chest approach [11,12,14]. One of the most difficult aspects was the proper positioning of the trocars in the chest cavity. In order to perform the procedure more easily we studied the best positioning of this system. The arm cart was placed behind the operative site and the best position of the robotic arms was established in relation to the side of the lesion. This position allowed the surgeon to have an excellent, unobstructed view of the chest cavity without arm impingement and interference.
Lastly, other two problems became evident and should be addressed in the future:
To the best of our knowledge, this is the first report on robotic surgery for thoracic diseases, using a robotic manipulator system. Although further studies on many robotic procedures are necessary to clarify the clinical feasibility and utility of our procedures, the results in this preliminary experience are encouraging. We believe that robotic procedures may be technically feasible in selected cases and in the hands of an experienced thoracic surgeon. Nevertheless, due to its technical features, it is currently indicated for reconstructive surgery. As robotic systems and their arm instruments are improved and adapted to thoracic surgery, their application will be extended to a wider range of operations and operating times will be significantly reduced.
| Footnotes |
|---|
| Appendix A. Conference discussion |
|---|
|
|
|---|
Dr Melfi: Initially, the lobectomy was very long, 5 h. You should consider that the first 2 h were reserved for the setting up of the machine, because at the beginning it took a long time to choose the positions, because it is very different from cardiac surgery. We didn't really know the proper position. So we tested it, we studied this position, and at the moment the times have become much shorter, about 2.5 h.
Dr Casselman: Another issue also is that it is sometimes difficult to estimate the force that you are exerting on the arms to tie knots or whatever, and, I don't know, but maybe in pulmonary artery surgery where you sometimes have some fragile structures, did you have any problems with that, have you torn up an artery or whatever by making the knots on the pulmonary artery branches?
Dr Melfi: This was one of the most difficult issues because you don't really feel the tension, but we found it is possible, with experience, to improve this perception facility.
Professor A. Yim (Shatin, Hong Kong): One concern I have is the safety of this approach: if you get into major bleeding, how are you going to control it using the robotic system? Also, the main advantage of robotic technology is to allow port access to perform complex procedures. However, if you require a mini-thoracotomy anyway to retrieve the specimen, it seems that you are already defeating the purpose of robotics, and all you are doing is to make the operation more complicated.
Dr Melfi: Yes, I agree, the advantage at the moment is for the surgeon, of course. In comparison to video surgery, the surgeon is sitting and he doesn't have any problem with orientation. When you use the instruments by video surgery, of course you use these instruments, but you are also looking at the display. And I agree with your comment about the small incision, but we don't have all the instruments at the moment. We have very few robotic instruments, and we must use standard endoscopic instruments through a small incision. We just tested the feasibility of this procedure.
Dr P. Wurnig (Vienna, Austria): Had you any training for your surgeons before starting this project?
Dr Melfi: Yes, we did.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
R. Waseda, N. Ishikawa, M. Oda, I. Matsumoto, Y. Ohta, N. Inaki, Y. Hirano, and G. Watanabe Robot-assisted endoscopic airway reconstruction in rabbits, with the aim to perform robot-assisted thoracoscopic bronchoplasty in human subjects. J. Thorac. Cardiovasc. Surg., October 1, 2007; 134(4): 989 - 995. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Rea, G. Marulli, L. Bortolotti, P. Feltracco, A. Zuin, and F. Sartori Experience With the "Da Vinci" Robotic System for Thymectomy in Patients With Myasthenia Gravis: Report of 33 Cases Ann. Thorac. Surg., February 1, 2006; 81(2): 455 - 459. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. J. Park, R. M. Flores, and V. W. Rusch Robotic assistance for video-assisted thoracic surgical lobectomy: Technique and initial results J. Thorac. Cardiovasc. Surg., January 1, 2006; 131(1): 54 - 59. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Mohr, G. S. Nadzam, and M. J. Curet Totally Robotic Roux-en-Y Gastric Bypass Arch Surg, August 1, 2005; 140(8): 779 - 786. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M.A. Melfi, M. C. Ambrogi, M. Lucchi, and A. Mussi Video robotic lobectomy MMCTS, June 28, 2005; 2005(0628): 448. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Bodner, H. Wykypiel, A. Greiner, W. Kirchmayr, M. C. Freund, R. Margreiter, and T. Schmid Early experience with robot-assisted surgery for mediastinal masses Ann. Thorac. Surg., July 1, 2004; 78(1): 259 - 265. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hashizume and K. Tsugawa Robotic Surgery and Cancer: the Present State, Problems and Future Vision Jpn. J. Clin. Oncol., May 1, 2004; 34(5): 227 - 237. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Bodner, H. Wykypiel, G. Wetscher, and T. Schmid First experiences with the da VinciTM operating robot in thoracic surgery Eur. J. Cardiothorac. Surg., May 1, 2004; 25(5): 844 - 851. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Iwasaki, K. Okabayashi, and T. Shirakusa A model to assist training in thoracoscopic surgery Interactive CardioVascular and Thoracic Surgery, December 1, 2003; 2(4): 697 - 701. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. C. Giulianotti, A. Coratti, M. Angelini, F. Sbrana, S. Cecconi, T. Balestracci, and G. Caravaglios Robotics in General Surgery: Personal Experience in a Large Community Hospital Arch Surg, July 1, 2003; 138(7): 777 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Morgan, M. E. Ginsburg, J. R. Sonett, D. L.S. Morales, T. Kohmoto, L. A. Gorenstein, C. R. Smith, and M. Argenziano Advanced thoracoscopic procedures are facilitated by computer-aided robotic technology Eur. J. Cardiothorac. Surg., June 1, 2003; 23(6): 883 - 887. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |